Scope
GB/Z 33875-2017 (Guidelines for the use of GB/T 2624-2006) is available as an English-translated PDF.
GB/Z 33875-2017 is the Chinese standard "Guidelines for the use of GB/T 2624-2006". Its scope clause reads: This Guidance Document gives guidance on the use of GB/T 2624-2006 (all parts).
GB/T 2624-2006 is a circle The pressure drop caused by the contraction in the shape pipe is based on the national standard for measuring the flow (see 5.1 of GB/T 2624.1-2006).
It is based on traffic measurement The amount of theory and experimental work carried out a series of rules and requirements. The details of the range see GB/T 2624.1-2006 Chapter 1.
This document applies to the definition and symbols see GB/T 2624.1- 2006 Chapter 3, Chapter 4. GB/T 2624.1-2006 and this document do not discuss the theoretical background details, the content can refer to other related to the fluid flow of teaching Book.
According to the provisions and requirements of GB/T 2624.1-2006, the uncertainty of the flow measurement can be achieved to about 1% of the calculated value of the flow.
Before selecting the most suitable type of differential pressure device for a particular application, consider each of the types given in GB/T 2624-2006 (Parts 2 to 4) Limit the use of a device.
Parts 2 to 4 also serve as a basis for preliminary design of the metrology system. GB/T 2624-2006 (parts 2 to 4) gives the detailed design, manufacture and final inspection necessary information.
GB/T 2624.1-2006 does not include secondary devices, but Chapter 6 of this document made a normative reference to ISO 2186. Its clauses include terms and definitions.
Found what you need?
Document preview — GB/Z 33875-2017
National Standard of the People's Republic of China
- ICS
- 17.120.10
- Classification
- N 12
Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Contents
- Preface
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 The corresponding relationship between this guide and GB/T 2624 (all parts)
- 5 GB/T 2624-2006 (all parts) user guide
- 5.1 GB/T 2624.1-2006 Guidelines for use
- 6 General information relevant to the application of GB/T 2624-2006 (all parts)
- 6.1 Secondary device
- 6.2 Measurement of pressure and differential pressure
- 6.3 Temperature Measurement
- 6.4 Determination of density
- 6.5 Power and Electrical Equipment
- Appendix A (informative) measurement and calculation principle
- Appendix B (Informative) Calculation of Natural Gas Compressibility
- Appendix C (informative) orifice assembly
- References
1 Scope
This Guidance Document gives guidance on the use of GB/T 2624-2006 (all parts). GB/T 2624-2006 is a circle
The pressure drop caused by the contraction in the shape pipe is based on the national standard for measuring the flow (see 5.1 of GB/T 2624.1-2006). It is based on traffic measurement
The amount of theory and experimental work carried out a series of rules and requirements.
The details of the range see GB/T 2624.1-2006 Chapter 1. This document applies to the definition and symbols see GB/T 2624.1-
2006 Chapter 3, Chapter 4.
GB/T 2624.1-2006 and this document do not discuss the theoretical background details, the content can refer to other related to the fluid flow of teaching
Book.
According to the provisions and requirements of GB/T 2624.1-2006, the uncertainty of the flow measurement can be achieved to about 1% of the calculated value of the flow.
Before selecting the most suitable type of differential pressure device for a particular application, consider each of the types given in GB/T 2624-2006 (Parts 2 to 4)
Limit the use of a device. Parts 2 to 4 also serve as a basis for preliminary design of the metrology system.
GB/T 2624-2006 (parts 2 to 4) gives the detailed design, manufacture and final inspection necessary information.
GB/T 2624.1-2006 does not include secondary devices, but Chapter 6 of this document made a normative reference to ISO 2186.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version applies to this article
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 2624.1-2006 Measurement of full pipe fluid flow using differential pressure devices installed in circular sectioned pipes - Part 1. General
Principles and requirements (ISO 5167-1.2003, IDT)
GB/T 2624.2-2006 Measurement of full pipe fluid flow using a differential pressure device installed in a circular sectioned pipe - Part 2 - Orifice (ISO 5167-2.2003, IDT)
GB/T 2624.3-2006 Manifold fluid flow measurement using a differential pressure device mounted in a circular sectioned pipe - Part 3. Nozzle
And Venturi nozzle (ISO 5167-3.2003, IDT)
GB/T 2624.4-2006 Manifold fluid flow measurement using differential pressure devices installed in circular sectioned pipes - Part 4 Ventura
In tube (ISO 5167-4.2003, IDT)
ISO 2186 Measurement of fluid flow in closed conduits Connection of pressure signals between primary and secondary units (Fluid flowinclosedconduits-Connectionsforpressuresignaltransmissionsbetweenprimaryandsecondary elements
ISO 4006 closed pipe fluid flow measurement terms and symbols (Measurementoffluidflowinclosedcon- duits-Vocabularyandsymbols)
ISO /T R3313.1998 Measurement of Fluid Flow in Closed Pipes Flow Pulse Effects on Flow Measuring Instruments (Meas- urementoffluidflowinclosedconduits-Guidelinesontheffectsofflowpulsationsonflow-meas- urementinstruments)
3 Terms and definitions
ISO 4006 defined terms and definitions apply to this document.
GB/T 778.1 | GB/T 778.4 | GB/T 21117 | GB/T 42567.5 | GB/T 28857 | […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 98 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 2624.1-2006Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full—Part 1: General principles and requirements
- GB/T 2624.2-2006Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full—Part 2: Orifice plates
- GB/T 2624.3-2006Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full—Part 3: Nozzles and Venturi nozzles
- GB/T 2624.4-2006Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 4: Venturi tubes
ISO 5167 · ISO 2186 · ISO 4006
How to Download GB/Z 33875-2017
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 2624.1-2006 — Full differential pressure device installed in a pipe of circular cross-section measuring fluid flow -- Part 1: General principles and requirements
GB/T 2624.2-2006 — Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 2: Orifice plates
GB/T 2624.3-2006 — Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 3: Nozzles and Venturi nozzles
Secure payment via Stripe
Payments accepted
GB/Z 33875-2017
$650.00