GB/T 25306-2010Standard of electron accelerator facility engineering for radiation processing (English PDF)
辐射加工用电子加速器工程通用规范
This is a limited preview
Buy now to download the full PDF (25 pages)
Need quotation for your management?
Get a formal quotation for GB/T 25306-2010 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
November 10, 2010
Implementation date
May 1, 2011
Scope
GB/T 25306-2010 is the English-translated version of 辐射加工用电子加速器工程通用规范.
GB/T 25306-2010 specifies the composition and the technical requirements of a radiation processing electron accelerator project: the classification and model naming of the electron accelerator means and of the under beam means, the content, requirements, design, construction and quality supervision of the plant, the installation and testing, and the acceptance.
Clause 1 applies it to radiation processing electron accelerator projects of every type in the energy range 0.15 MeV to 15 MeV.
The table of contents runs from the scope and the normative references through the terms and definitions, the composition of the project, the electron accelerator means, the under beam means, the control system and the plant to installation and testing and finally acceptance, and closes with Appendix A on methods of measurement and formulae, which the foreword declares normative, and three informative annexes: Annex B on individual dose limits and the effective dose for different tissues or organs, Annex C on occupational exposure limits for microwaves, high frequency electromagnetic fields and harmful gases, and Annex D on the measurement of beam focal spot diameter, scanning frequency and pulse repetition rate.
Clause 3 defines five terms: radiation processing, the process of acting on materials with ionizing radiation to obtain the intended quality or performance; radiation facility, made up of the radiation chamber, the electron accelerator system, the under beam apparatus, the control and radiation processing equipment systems, the safety facilities and other parts; the radiation processing electron accelerator apparatus, the means for generating and accelerating the electron beam and extracting it for radiation processing; the under beam apparatus, the means outside the beam extraction window that transports the materials for radiation processing; and the reference plane, the plane selected perpendicular to the beam axis in the radiation field.
The draft on the page stops at the end of clause 3, so the project composition, plant, installation and acceptance clauses themselves are not shown; the page estimates the full text at about 28,280 words.
Clause 2 cites GB 3095, GB 5172-1985, GB 5749, GB/T 15447, GB/T 16841, GB 18871-2002, GBZ 1-2002, GBZ 2.1-2007, GBZ 2.2-2007 and JJG 772.
It was proposed by China National Nuclear Corporation, is handled by the National Standardization Technical Committee of nuclear energy and was drafted mainly by the Shanghai Institute of Applied Physics of the Chinese Academy of Sciences, the Beijing Institute of Machinery Industry Automation and the Institute of Nuclear Industry Standardization, among others the page names. It was issued on 2010-11-10 and has applied since 2011-05-01.
Found what you need?
Document preview — GB/T 25306-2010
National Standard of the People's Republic of China
- ICS
- 27.120.30
- Classification
- F 50
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 radiation processing electron accelerator project consisting of
- 5 electron accelerator means
- 7 control system
- 9 Installation and testing
- 10 14 acceptance
- Appendix A (normative) Methods of measurement and Formula
- Annex B (informative) individual dose limits and different tissues or organs, the effective dose
- Annex C (informative) personal microwave, high-frequency electromagnetic fields harmful gases and occupational exposure limits Measurement Annex D (informative) beam focal spot diameter, scanning frequency, pulse repetition rate of
Foreword
Appendix A of this standard is a normative appendix, Appendix B, Appendix C, Appendix D are informative appendices. The standard proposed by China National Nuclear Corporation.
1 Scope
This standard specifies the radiation processing electron accelerator project composition and technical requirements; classification means and electronic accelerator beam under the device, Model name; the content of plant construction, requirements, design, construction and quality supervision; installation and testing; acceptance.
This standard applies to all types of energy radiation processing 0.15MeV ~ 15MeV an electron accelerator project.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB 3095 Ambient Air Quality Standard
GB 5172-1985 particle accelerator radiation protection
GB 5749 drinking water health standards
GB/T 15447 X, conversion method gamma-ray and electron beam radiation absorbed doses of different materials
GB/T 16841 energy of 300keV ~ 25MeV electron beam radiation processing dosimetry guidelines
GB 18871-2002 ionizing radiation protection and safety of radiation sources basic standards
GBZ 1-2002 Design of Industrial Enterprises hygiene standards
GBZ 2.1-2007 Workplace Hazardous Occupational Exposure Limits - Part 1: Chemical hazardous agents
GBZ 2.2-2007 Workplace Hazardous Occupational Exposure Limits - Part 2: physical factors
JJG 772 electron beam radiation (Radiation Processing)
3 Terms and Definitions
The following terms and definitions apply to this standard.
3.1 Radiation Processing
Ionizing radiation effects on materials to achieve a quality or performance requirements of the process expected.
3.2 Radiation means
By the radiation chamber, electronic accelerator system, beam apparatus under the control of radiation processing equipment systems, security facilities and other components.
3.3 Radiation processing electron accelerator device
Electron accelerator apparatus
Generation, accelerated electron beam extraction means for radiation processing.
3.4 Under beam apparatus
Refers beam extraction under the window (outside), means for transporting materials for radiation processing.
3.5 Reference plane
Radiation field perpendicular to the beam axis of the selected plane.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 25 pages — is available in the English PDF.
Referenced standards
Normative references
- GB 3095Ambient air quality standards
- GB 5172-1985Regulations for radiation safety and protection of particle accelerators
- GB 5749Standards for drinking water quality
- GB/T 15447Conversion method of absorbed doses in different materials irradiated by X, gamma rays and election beams
- GB/T 16841Guide for dosimetry in an electron beam facility for radiation processing at energies between 300 keV and 25 MeV
- GB 18871-2002Basic Standards for Protection Against Ionizing Radiation and for the Safety of Radiation Sources
GB Z1-2002 · GB Z2.1-2007 · GB Z2.2-2007 · JJG 772
Cited by
- GB/T 18525.11-2026Irradiation processing practice for agricultural products — Part 11: Dried longan
- GB/T 20130-2025Self-shielding electron beam facility for radiation processing
- GB/T 40590-2021Specification for operation and maintenance management of electron accelerator facility for radiation processing
- GB/T 36773-2018Technical rule of phytosanitary treatment for bamboo products
Similar standards
How to Download GB/T 25306-2010
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 18871-2002 — Basic Standards for Protection Against Ionizing Radiation and for the Safety of Radiation Sources
GB 3095-2012 — Ambient air quality standards
GB 3095-2026 — Ambient air quality standards
Secure payment via Stripe
Payments accepted
GB/T 25306-2010
$435.00