GB/T 2286-2017Determination of total sulfur composition of coke (English PDF)
焦炭全硫含量的测定方法
This is a limited preview
Buy now to download the full PDF (19 pages)
Need quotation for your management?
Get a formal quotation for GB/T 2286-2017 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
October 14, 2017
Implementation date
May 1, 2018
Scope
GB/T 2286-2017 is the English-translated version of 焦炭全硫含量的测定方法.
GB/T 2286-2017 is the Chinese national standard for measuring the total sulfur composition of coke.
It describes four methods - the Eschka method, which is the arbitration method, high temperature combustion, coulometric titration and infrared spectroscopy - and for each one gives the principle, the reagents and materials, the instruments and equipment, the collection of the specimen, the test steps, the calculation of the result and the precision.
It applies to coke and to semi-coke (blue charcoal). Specimens are prepared according to GB/T 1997, the air-dry moisture used to calibrate the sulfur meters comes from GB/T 2001, and results are rounded off following GB/T 8170.
Two closing clauses cover how the result is expressed and what the test report must contain. It replaces GB/T 2286-2008, was issued on 14 October 2017 and has applied since 1 May 2018.
Found what you need?
Document preview — GB/T 2286-2017
National Standard of the People's Republic of China
- ICS
- 75.160.10
- Classification
- H 32
- Replacing
- GB/T 2286-2008
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword3
- 1 Scope4
- 2 Normative references4
- 3 Eschka method (arbitration method)4
- 4 High temperature combustion method8
- 5 Coulometric titration method12
- 6 Infrared spectroscopy method16
- 7 Result expression19
- 8 Test report19
1 Scope
This Standard specifies the method principle, reagents and materials, instruments and equipment, specimen collection, test steps, result calculation and precision for the determination of total sulfur composition in coke by Eschka method, high temperature combustion method, coulometric titration and infrared spectroscopy. This Standard applies to coke and semi-coke (blue charcoal).
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
GB/T 601, Chemical reagent -- Preparations of reference titration solutions
GB/T 1997, Coke -- Sampling and preparation of samples
GB/T 2001, Coke -- Determination of proximate analysis
GB/T 8170, Rules of rounding off for numerical values and expression and judgement of limiting values
3 Eschka method (arbitration method)
3.1 Principle
Thoroughly mix the specimen with Eschka reagent. Burn at a certain temperature to convert the sulfur in the specimen into sulfate. The sulfate ions are then allowed to form barium sulfate precipitates. Calculate the total sulfur composition in the specimen based on the mass of barium sulfate.
3.2 Reagents and materials
Unless otherwise stated, only reagents confirmed to be analytically pure and distilled or deionized water or water of equivalent purity are used in the analysis.
3.2.1 Magnesium oxide: chemically pure.
3.2.2 Anhydrous sodium carbonate: chemically pure.
3.2.3 Eschka reagent: Weigh 2 portions by mass of magnesium oxide and 1 portion by mass of anhydrous sodium carbonate. Grind until the particle size is less than 0.2 mm. Mix evenly and store in an airtight container.
3.2.4 Hydrogen peroxide: The concentration is 30%.
3.2.5 Hydrochloric acid solution: The density is 1.19 g/cm³
3.2.6 Nitric acid: The density is 1.42 g/cm³
3.2.7 Barium chloride solution (100 g/L): Weigh 100 g of barium chloride and dissolve in water. Dilute to 1000 mL with water.
3.2.8 Hydrochloric acid solution (1+1): 1 volume of hydrochloric acid plus 1 volume of water and mix well.
3.2.9 Silver nitrate solution (10 g/L): Weigh 1 g of silver nitrate and dissolve it in water. Dilute to 100 mL with water. Add a few drops of nitric acid, and store in a dark bottle.
3.2.10 Methyl red indicator solution (1 g/L): Weigh 0.1 g of methyl red and dissolve it in 50 mL of ethanol. Dilute to 100 mL with water.
3.2.11 Qualitative filter paper: medium speed; phi90 mm~phi110 mm.
3.2.12 Quantitative filter paper: medium speed; phi90 mm~phi110 mm.
3.3 Instruments and equipment
3.3.1 Analytical balance: sensitive to 0.0001 g.
3.3.2 Pallet balance: sensitive to 0.01 g.
3.3.3 Muffle furnace: equipped with temperature control device; can maintain the temperature between 800°C~850°C; the temperature can be adjusted; the furnace can be ventilated.
3.3.4 Desiccator: with built-in color-changing silica gel or granular anhydrous calcium chloride.
3.3.5 Beaker.
3.3.6 Porcelain crucibles: 30 mL and 20 mL.
3.4 Specimen preparation
Carry out in accordance with the provisions of GB/T 1997.
3.5 Test steps
3.5.1 Weigh 2 g (accurate to 0.1 g) of Eschka reagent (see 3.2.3) and 1 g (accurate to 0.0001 g) of the specimen with a particle size less than 0.2 mm in a 30 mL porcelain crucible (see 3.3.6). Use nichrome wire to mix evenly. Then cover the specimen with 1 g (accurate to 0.1 g) of Eschka reagent (see 3.2.3).
3.5.2 Move the crucible containing the specimen into the muffle furnace (see 3.3.3). Gradually increase the furnace temperature to 800°C~850°C within 1 h ~ 1.5 h. Heat at this temperature for 1 h~1.5 h.
3.5.3 Remove the crucible from the muffle furnace. After cooling to room temperature, use a glass rod to loosen the burning material (if any unburned specimen particles are found, continue burning at 800°C~850°C for 0.5 h). Transfer it to a beaker. Carefully rinse the inside of the crucible with hot water. Add the rinse solution to the beaker. Then add 100 mL~150 mL of hot water. Crush the burning object with a glass rod (if unburned specimen particles are found at this time, the test will be invalid).
3.5.4 Add 1 mL of hydrogen peroxide (see 3.2.4) into the beaker. Heat it to 80°C and keep it for 30 min.
3.5.5 Filter with qualitative filter paper (see 3.2.11). Rinse the burn onto the filter paper with hot distilled water. Continue to rinse the burned material from the filter paper carefully with hot distilled water. The number of times shall not be less than 10 times.
3.5.6 Boil the filtrate for 2~3 min. Drain excess hydrogen peroxide. Add 2 ~ 3 drops of methyl red indicator solution (see 3.2.10) to the filtrate to indicate whether the elimination is complete. Add hydrochloric acid solution (see 3.2.8) dropwise until the color turns red. Add another 1 mL. Boil for 5 min to remove carbon dioxide. The volume of the solution at this time is approximately 200 mL.
3.5.7 Cover the beaker with a watch glass. Reduce heat until solution stops boiling. Remove the watch glass. Slowly drop 10 mL of barium chloride solution (see 3.2.7) into the hot solution. Stir the solution simultaneously. Cover the watch glass. Keep the solution at a temperature just below the boiling point for 30 min.
3.5.8 After the solution is cooled, filter it with quantitative filter paper (see 3.2.12). Wash with hot water until there is no chloride ion [use silver nitrate solution (see 3.2.9) to check that there is no turbidity].
3.5.9 Move the precipitate together with the filter paper into a 20 mL porcelain crucible of known mass (see 3.3.6). Ash the filter paper at low temperature first. Then move it into a muffle furnace with a temperature of 800°C~850°C and burn for 20 min. […]
4 High temperature combustion method
4.3 Instruments and equipment
4.3.1 High-temperature tube furnace: heated with silicon carbon rods or silicon carbon tubes, with a temperature control device to maintain the furnace temperature within the range of (1250±10)°C.
4.3.2 Combustion tube: made of high-temperature porcelain, corundum or quartz; the total length of the tube is about 750 mm; one end has an outer diameter of 22 mm, an inner diameter of 19 mm, and a length of about 690 mm; the other end has an outer diameter of 10 mm, an inner diameter of about 7 mm, and a length of about 60 mm.
4.3.3 Combustion boat: made of high-temperature porcelain or corundum; the length is 77 mm, the top width is 12 mm, the bottom width is 9 mm, and the height is 8 mm.
4.3.4 Absorption flask: Erlenmeyer flask, with a volume of 250 mL.
4.3.5 Nickel-chromium wire hook: the diameter is about 2 mm; the length is 650 mm; one end is bent into a small hook.
4.3.6 Silicone rubber tube: the outer diameter 11 mm; the inner diameter 8 mm; the length is approximately 80 mm.
4.3.7 Acid burettes: 25 mL and 10 mL.
4.3.8 Alkali burettes: 25 mL and 10 mL.
4.3.9 Ear wash ball.
4.3.10 Measuring cylinder.
4.3.11 Analytical balance: sensitive to 0.0001 g.
4.4 Specimen preparation
Carry out in accordance with the provisions of GB/T 1997.
4.5 Test steps
4.5.1 Test preparation
4.5.1.1 Connect the instruments according to the sequence in Figure 1 for later use. […]
5 Coulometric titration method
5.2.3 Combustion boat: bisque or corundum product; the length of the sample loading part is about 60 mm; the temperature resistance is above 1200°C.
5.3 Instruments and equipment
5.3.1 Coulomb sulfur meter: According to the principle of coulomb analysis, the titration process is detected and controlled through double platinum indicator electrodes. Use a microcomputer to control the temperature of the combustion furnace and the test process in real time and perform data processing. Automatically calculate and display the milligrams or mass fraction of sulfur in the specimen. Coulomb sulfur meter mainly consists of the following parts.
5.3.1.1 Combustion furnace: equipped with a temperature measurement and control device, capable of raising the temperature to above 1200°C, and a high-temperature constant temperature zone of at least 70 mm long. The furnace is equipped with a combustion tube with a different diameter that can withstand a temperature of above 1300°C.
5.3.1.2 Sample delivery controller: the specimen can be automatically sent into the combustion tube; the specimen injection speed and stroke can be freely adjusted; the specimen can be flexibly moved forward and backward according to prescribed procedures.
5.3.1.3 Electrolytic cell: the electrolytic cell is divided into two parts: the upper cover and the cell body. The upper cover of the electrolytic cell is fixed with an electrolytic electrode pair and an indicating electrode pair, with a capacity of not less than 400 mL.
5.3.1.4 Electromagnetic stirrer: the electromagnetic stirrer drives the magnetic stirrer in the electrolytic cell to rotate through the stirrer to stir the electrolyte. The stirring rate can be adjusted through the stirring adjustment knob on the control panel.
5.3.1.5 Air supply and purification device: composed of electromagnetic pump and purification pipe. The gas supply volume is about 1500 mL/min; the gas extraction volume is about 1000 mL/min; the purification tube is filled with color-changing silica gel.
5.3.2 Analytical balance: sensitive to 0.0001 g.
5.4 Test steps
5.4.1 Test preparation
5.4.1.1 Turn on and debug the equipment according to the instrument instruction manual. Put it in a normal test state. Raise the temperature of the combustion furnace to 1150°C.
5.4.1.2 Fill the outlet of the combustion tube with clean and dry glass fiber wool.
5.4.1.3 Start the air extraction and supply pumps. Adjust the suction flow to 1000 mL/min. Then close the piston between the electrolytic cell and the combustion tube. If the air pumping volume can be reduced to less than 300 mL/min, it proves that the air tightness of each component and interface of the instrument is good and the measurement can be carried out. Otherwise, check the various components of the instrument and their interfaces. Recheck air tightness.
5.4.2 Instrument calibration
5.4.2.1 Calibration method
Use certified standard samples and perform instrument calibration according to one of the following methods.
5.4.2.1.1 Multi-point calibration method: Calibrate with at least 3 certified standard samples whose sulfur content can cover the sulfur content range of the sample being tested.
5.4.2.1.2 Single-point calibration method: Use a standard sample with a sulfur content similar to that of the sample to be measured for calibration.
5.4.2.2 Calibration procedure
5.4.2.2.1 Determine the air-dry basis moisture of the standard sample according to GB/T 2001. Calculate the standard value of total sulfur St,ad on an air-dry basis.
5.4.2.2.2 According to the steps in 5.4.3, use the calibrated instrument to measure the sulfur content of the standard sample. Each standard sample is measured at least three times. The average value of three measured values is the measured sulfur value of the standard sample.
5.4.2.2.3 Input the sulfur measured value of the standard sample and the air-dry basis standard value into the sulfur meter (or the instrument automatically reads it) to generate a correction coefficient.
NOTE: Some instruments may require manual calculation of correction coefficients before entering them into the instrument.
5.4.2.3 Calibration validity verification
Select another 1 ~ 2 standard samples or other control samples. Use a calibrated sulfur meter to measure the total sulfur content according to step 5.4.3. If the difference between the measured value and the standard value (control value) is within the uncertainty range (control limit) of the standard value (control value), the calibration is valid. Otherwise, the cause shall be identified and recalibrated.
5.4.3 Determination steps
6 Infrared spectroscopy method
6.4.2.1 Calibration method
Use certified standard samples to calibrate the sulfur meter according to one of the following methods.
6.4.2.1.1 Multi-point calibration method: Calibrate with at least 3 certified standard samples whose sulfur content can cover the sulfur content range of the sample being tested.
6.4.2.1.2 Single-point calibration method: Use a standard sample with a sulfur content similar to that of the sample to be measured for calibration.
6.4.2.2 Calibration procedure
6.4.2.2.1 Determine the air-dry basis moisture of the standard sample according to GB/T 2001. Calculate the standard value of total sulfur St,ad on an air dry basis.
6.4.2.2.2 According to the steps in 6.4.3, use the calibrated instrument to measure the sulfur content of the standard sample. Measure each standard sample at least three times. The average value of the three measured values is the sulfur measured value of the standard sample.
6.4.2.2.3 Input the sulfur measured value of the certified standard sample and the air-drying standard value into the sulfur meter (or the instrument automatically reads it) to generate a working curve or correction coefficient.
NOTE: Some instruments may require manual calculation of correction coefficients before entering them into the instrument.
6.4.2.3 Calibration validity verification
Select another 1 ~ 2 standard samples or other control samples. Use a calibrated sulfur meter to measure the total sulfur composition. If the difference between the measured value and the standard value (or control value) is within the uncertainty range (or control limit) of the standard value (or control value), the calibration is valid. Otherwise, the cause shall be identified and recalibrated.
6.4.3 Determination steps
6.4.3.1 After heating the high-temperature furnace to 1250°C, introduce oxygen. Adjust the flow regulation system. Control the oxygen flow at 3.0 L/min.
6.4.3.2 Weigh (0.3±0.01) g of air-dried specimen with a particle size less than 0.2 mm (accurate to 0.0001) in the combustion boat. Place the combustion boat on the setting device. Follow the instrument instruction manual, start the program, and perform the test. The system will automatically analyze the sulfur content in the sample. After the specimen is completely burned, the instrument displays and prints out the mass fraction of sulfur in the specimen. […]
6.4.4 Calibration check
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 19 pages — is available in the English PDF.
Referenced standards
Normative references
Cited by
- NB/T 11457-2023Technical guidelines for coal blending in coking
- GB/T 39769-2021Determination of forms of sulfur in coke
- GB/T 1996-2017Coke for metallurgy
- GB/T 8729-2017Foundry coke
- YS/T 119.3-2008Determination and calculation of heat balance of special equipments for alumina production. Part 3: Upright lime furnace
Similar standards
Editions of GB/T 2286
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB/T 2286-2017 | Determination of total sulfur composition of coke | current edition | Current |
| GB/T 2286-2008 | Determination of total sulfur composition of coke | previous edition | Superseded |
This page sells the current edition, GB/T 2286-2017. Earlier editions are listed for reference only.
How to Download GB/T 2286-2017
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 1997-2008 — Coke-sampling and preparation of samples
GB/T 19970-2005 — Thompson Seedless
GB/T 19970-2026 — Thompson seedless grapes
Secure payment via Stripe
Payments accepted
GB/T 2286-2017
$205.00