Valid

GB 26875.1-2011Remote-monitoring system of urban fire protection - Part 1: User information transmission device (English PDF)

城市消防远程监控系统 第1部分:用户信息传输装置

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB 26875.1-2011 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China

Level / Type

National · Mandatory

Issue date

July 29, 2011

Implementation date

May 1, 2012

Scope

GB 26875.1-2011 is the English-translated version of 城市消防远程监控系统 第1部分:用户信息传输装置.

GB 26875.1-2011 is Part 1 of the six-part national standard on remote-monitoring systems of urban fire protection and specifies the terms and definitions, requirements, test methods, inspection rules and marking of the user information transmission device, the unit installed in a networked building that passes fire alarm, facility status and manual alarm information to the monitoring centre.

It applies to such devices installed in general industrial and civil buildings; Clauses 4 and 7 are mandatory and the remainder is recommended.

The requirements cover transmission of fire alarm, facility operating status and manual alarm information to the monitoring centre within 10 s with priority rules, patrol inspection and duty check responses, local fault alarms within 100 s, self-test, main and standby power supplies (85 % to 110 % of 220 V, at least 8 h of standby operation), insulation resistance of 20 MOmega and 50 MOmega, electric strength at 1 250 V, electromagnetic compatibility, climatic and mechanical environment tests, software, three operation levels, and main components such as indicator lamps, displays, audible devices, fuses, terminals, batteries and wiring.

The communication protocol and retransmission mechanism refer to GB/T 26875.3-2011 and the operating status information to GB 50440. Issued on 29 July 2011 and in force since 1 May 2012.

Classification: ICS 13.220.20, CCS C81. The document runs to 15 pages, delivered complete in English translation.

Found what you need?

Document preview — GB 26875.1-2011

National Standard of the People's Republic of China

ICS
13.220.20
Classification
C81

Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Requirements

3 Terms and definitions

4 Requirements

Foreword

Clause 4 and Clause 7 of this part are mandatory; the rest is recommended.

GB 26875 Remote-monitoring system of urban fire protection is divided into six parts:

- Part 1: User information transmission device;

- Part 2: Functional requirements for communication server software;

- Part 3: Communication protocol for the alarm transmission network;

- Part 4: Basic data items;

- Part 5: Functional requirements for alarm receiving software;

- Part 6: Functional requirements for information management software.

This part is Part 1 of GB 26875.

This part was drafted in accordance with the rules given in GB/T 1.1-2009.

Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. The issuing body of this document shall not be held responsible for identifying any or all such patent rights.

This part is under the jurisdiction of the Fire Communication Subcommittee of the National Technical Committee for Fire Protection Standardization (SAC/TC 113/SC 14).

Responsible drafting organization of this part: Shenyang Fire Research Institute of the Ministry of Public Security.

Participating drafting organizations of this part: Wansheng (China) Technology Co., Ltd., Gulf Fire Network Co., Ltd., Shenyang Meibao Control Co., Ltd., Tsinghua Tongfang Co., Ltd., Guangdong Baixun Information Technology Co., Ltd., Shanghai Yida Communication Company, Fujian Sheng'an Urban Safety Information Development Co., Ltd. and Beijing Wangxun Qingniao Technology Development Co., Ltd.

Main drafters of this part: Wang Jun, Sui Hulin, Jiang Xueyun, Xu Fang, Zhang Lei, Ma Qingbo, Li Zhigang, Liu Meng, Lu Rixin, Zhao Hui, Jia Genlian, Yan Zhiming, Gao Hong, Miao Zhansheng, Xu Wenfei, Chen Xingyu, Feng Quanhui and Liu Qiming.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

Editions of GB 26875.1

EditionTitleRevisionStatus
GB 26875.1-2011Remote-monitoring system of urban fire protection - Part 1: User information transmission devicecurrent editionCurrent

This page sells the current edition, GB 26875.1-2011. Earlier editions are listed for reference only.

How to Download GB 26875.1-2011

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB 26875.1-2011

$255.00