GB 25280-2016Road traffic signal controller (English PDF)
道路交通信号控制机
Open the GB 25280-2016 preview as PDF
This is a limited preview
Buy now to download the full PDF (24 pages)
Issued by
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China
Level / Type
National · Mandatory
Issue date
December 13, 2016
Implementation date
December 13, 2016
Scope
GB 25280-2016 is the English-translated version of 道路交通信号控制机.
GB 25280-2016 is the Chinese national standard on road traffic signal controller, in the field of civil engineering. It carries no /T suffix, which in the Chinese system means compliance is mandatory: a product or a practice within its scope has to meet it to be lawfully made, sold or carried out in China. It was issued on 13 December 2016 by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China, and has been in force since 13 December 2016. Classification: ICS 93.080.30, CCS R87. This page is published from the official record of the standard held by the Chinese standards administration: the identification, the dates, the classification and the issuing body are taken from there. The clause text, the tables and the numeric limits are in the document itself, which is delivered complete in English translation.
Document preview — GB 25280-2016
National Standard of the People's Republic of China
- ICS
- 93.080.30
- Classification
- R87
Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China
Contents
- 1 Scope1
- 1 Terms and definitions1
- 3 Model Rules for the Classification and 41
- 4.1 Category1
- 5 Technical Requirements3
- 5.1 Physical Structure Properties in claim3
- 4 And electrical power supply device according 5.35
- 5.4 The basic functional requirements7
- 5.7 information security requirements10
- 5.10 climate adaptation requirements11
- 11 Mechanical strength in claim 11 5.12 5.13 11 consecutive job stability Test Method 611
- 12 And electrical power supply device checks 6.412
- 6.5 the load required to detect12
- 6.6 Functional Test12
- 6.7 fault monitoring test13
- 6.8 Information Security Testing13
- 6.9 Electrical safety testing14
- 6.14 Stability test of continuous work18
- 7 Inspection rules 1818
- 7.2 factory inspection18
- 7.3 qualified to determine19
- 8 Marking, labeling and packaging19
- 8.1 mark, label19
- 8.2 inspection certificate19
- 19 Annex A (normative) instruction and message format20
Foreword
5.3.4,5.3.10,5.4.2,5.4.3.1,5.4.4,5.4.5,5.5.2,5.5.3,
5.8 this standard is mandatory, the rest are recommended. This standard was drafted in accordance with rules GB/T 1.1-2009 given. This standard replaces GB 25280-2010 "Road traffic signal control machine" and GB/T 30502-2014 "urban road lane control signal System machine. " Compared with GB 25280-2010, editorial changes except main technical changes are as follows:
--- modify the normative references (see Chapter 2, the 2010 version of Chapter 2);
--- modify the terms and definitions (see Chapter 3, Chapter 3, 2010 edition);
--- revised classification (see 41, 2010 version 4.1, 4.2.);
--- increasing the model designation of the rules (see 4.2) and the identification code compiled rules (see 4.3);
--- Cabinet modified the structural design requirements, modify the cabinet main structural requirements (see 5.1 2, 2010 version 5.1.2), increase The bottom of the mounting hole size requirements [see 5.1.2e)];
--- increased inlet emergency power requirements (see 5.1.4.4);
--- modify the lightning protection requirements (see 534, 2010 edition of 5.3.4.);
--- modify the grounding requirements (see 5310, 2010 edition of 5.3.10.);
--- modify the basic conversion signal sequence, cited GB 14886 "Road Traffic lights setup and installation standard" requirement (see 5.4.3.1, 2010 version of 5.4.3.1);
--- modify the signal duration requirements (see 5432, 2010 version 5.4.3.2...);
--- the yellow flashing control means modify requirements (see 552, 2010 edition 5.5.2.);
--- Under the new classification, redefining the control requirements of various road traffic signal controller (see 5.6.1,
1 Scope
GB 25280-2016 is the Chinese national standard on road traffic signal controller, in the field of civil engineering. It carries no /T suffix, which in the Chinese system means compliance is mandatory: a product or a practice within its scope has to meet it to be lawfully made, sold or carried out in China. It was issued on 13 December 2016 by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China, and has been in force since 13 December 2016. Classification: ICS 93.080.30, CCS R87. This page is published from the official record of the standard held by the Chinese standards administration: the identification, the dates, the classification and the issuing body are taken from there. The clause text, the tables and the numeric limits are in the document itself, which is delivered complete in English translation.
This standard specifies the classification of road traffic signal control machine, technical requirements, test methods, inspection rules, marking, labeling and packaging. This standard applies to the traffic signal controller used on the road. Other places to use traffic signal controller can be implemented by reference.
2 Normative references
The following documents for the application of this document is essential. For dated references, only applies to the version dated paper Pieces. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 2423.1 electric and electronic products Environmental testing - Part 2. Test methods Test A. Cold
GB/T 2423.2 electric and electronic products Environmental testing - Part 2. Test Test Method B. High Temperature
GB/T 2423.3 electric and electronic products environmental testing - Part 2. Test Method Test Cab. Damp heat test
GB/T 2423.6 electric and electronic products environmental testing - Part 2. Test methods Test Eb and guidance. Bump
GB/T 2423.10 Environmental testing for electric and electronic products - Part 2. Test methods Test the Fc. vibration (sine)
GB/T 2423.38 Environmental testing for electric and electronic products - Part 2. Test Test Method R. Water test method and guidance
GB 4943.1 Safety of Information Technology Equipment Part 1. General Requirements
GB 14886 road traffic lights setup and installation specifications
GB/T 17626.2 Electromagnetic compatibility testing and measurement techniques electrostatic discharge immunity test
GB/T 17626.4 Electromagnetic compatibility testing and measurement techniques Electrical fast transient burst immunity test
GB/T 17626.5 Electromagnetic compatibility testing and measurement techniques surge (impact) immunity test
GB/T 17626.11 Electromagnetic compatibility Testing and measurement techniques - Voltage dips, short interruptions immunity tests and voltage variations
GB/T 19520.1-2007 electronic apparatus mechanical structure 482.6mm (19in) dimensions series of mechanical structures - Part 1. Panel And rack
3 Terms and Definitions
GB/T 31418 defines the terms and definitions apply to this document.
4.1 Classification
4.1.1 functional classification Road traffic signal controller (hereinafter, simply referred to as signal) divided by control signals A, B, C three categories (Table 1). Table 1 signal classification categories and basic control functions Reference signal type control signal A Class B Class C signal signal 1 yellow flashing control - - - Over 2 - - - Control period
3 Manual control - - - Induction - - Control 4 5 cable without coordinating control - - 6 networking control - - - 7 a single point of control to optimize - - 8 bus signal priority - 9 emergency priority -
Note. "-" should have the function of, "-" have appropriate functions.
4.1.2 Classification by installation environment Signal according to the installation environment can be divided into indoor and outdoor units. An indoor unit placed in the indoor or outdoor cabinet work and other non-open-air environment, the outdoor unit can be directly installed in the open air work.
4.1.3 by using a form of classification Signal by the use forms can be divided into fixed and mobile signal signal.
4.2 Model Rules for the Signal models include the functional classification, installation environment, use the form, working temperature levels, corporate self-encoded, shown in Figure 1.
1 signal Model Rules for the map
4.3 Rules for the identification code Rules for the identification code signal shown in Figure 2. Identifier used to uniquely identify each signal. FIG
5.1 Physical Structure performance requirements
5.1.1 Appearance Signal within the cabinet, the outer surface and the control panel should be smooth, flat, should not have dents, scratches, defects cracks, deformation and the like. Cabinet surfaces should There are strong anti-rust, anti-corrosion coating or painting, there should be no corrosion of metal parts and other mechanical damage, the sliding or rotating moving parts shall Ling Live, no loose fastening member, the outer surface of the cabinet may result should not have sharp corners or projections injury.
5.1.2 Cabinet structural design Signal enclosure design should satisfy.
a) the inner space of the cabinet should be large enough signal should facilitate cooling and installation, use and maintenance;
b) the cabinet shall be designed to reduce the intrusion of rain and dust and harmful substances as much as possible, and rack mount chassis design but also to prevent Water top surface area; Design
c) is such that the signal enclosure having sufficient mechanical strength to withstand the normal conditions to be expected in the transport, installation, Handling, operation and maintenance process, and should not be easily opened by a general tool;
d) employed in the form of foundations on the ground signal, the main structure inside the cabinet shall comply with GB/T 19520.1-2007 Chapter
4 Requirements specified;
e) using the signal based on the form of a mounting surface, a bottom mounting pore size should meet the requirements shown in FIG. 3 or FIG. 4. In millimeters Mounting Hole Size 1 (small-size) and a bottom signal
5.1.4 Door
5.1.4.1 cabinet doors Outdoor cabinet door should be sized as close as possible to the outer dimensions of the cabinet, the cabinet door should be greater than the maximum opening angle of 120 °. Door should be set There are strong locks to prevent unauthorized opening, there should be protection device on the door. Cabinet doors should be durable seams and resilient gasket, Should be continuous seal is provided, the gap should be intermittent. After the cabinet door, there should be no loose, deformation phenomena. In the inside of the cabinet door post the letter FIG physical layout of the machine No. of external terminals.
5.1.4.2 information boxes Signal to be provided inside the cabinet to store data storage cartridges User Manual, manual, wiring diagrams, maintenance records, etc., should be able to store the storage case A4 layout information, a minimum thickness of 20mm.
5.1.4.3 manual control gate The outdoor unit should be provided outside of the cabinet door or gate manual control, the user should be able to implement the manual control without opening the cabinet door. Door locks and manual control is provided with requirements 5.1.4.1, it should be compatible with the size of the cabinet structure size. Manual control gate should be provided on the machine , The position of the upper cabinet.
5.1.4.4 emergency power inlet External access to emergency power supply, emergency power supply should be provided in the inlet enclosure.
5.1.5 input and output wiring position For outdoor unit, in addition to the emergency power supply cable, all the input and output wiring cable wiring hole should be at the bottom of the cabinet through the signal The diameter of the wiring hole is at least 200mm. Wiring hole can not have sharp edges, to be closer to the center position of the wiring hole of the bottom of the cabinet.
5.2 text, graphics and marking requirements
5.2.1 General requirements Sign marked all of the following required, text, graphics should be durable, eye-catching and should not be easily removed, there should not curling. The operation panel, Setting interface, instructions and signs in Chinese characters should be used, if necessary can also use other characters simultaneously.
5.2.2 Operation Panel The operation panel or hand-held terminal application signal clear, compliant text, graphics, logos and the like to show it to function. in Parameter setting, the operation panel or the handheld terminal shall be able to work shows the set signal, the operation state, the control signal parameters, Tips should guide all kinds of items and contents of the input control parameters.
5.2.3 switches, buttons, a fuse Switches, buttons and the indicator on or near the application are clear, compliant text, graphics, to show its function, effects ON / Off state. In fuses should be clearly marked at the rated current of the fuse.
5.2.4 Terminals Each of the terminals based on the signal type or color of light output of the lamp response signal group of terminals, or code words, numbers for standard knowledge. Code, shall describe in detail the meaning of numbers in the user manual for wiring. Zero AC line signal, and the signal common grounding protective earth Application specification are words or symbols indicated. Exceeds the safety voltage of the signal during normal use of the machine operator is easily accessible (rms ac voltage not to exceed 36V, the DC voltage is not More than 60V) live parts, in its prominent position should be set to "Electrical Hazard" signs and take effective protective measures.
5.2.5 Socket Standard power outlet provided on the signal should be at its maximum load value indicated on the Vicinity of the output voltage and allow access.
5.2.6 Nameplate Signal should nameplate. Prominently plate should be securely attached to the signal, the plate size should be appropriate to the size and structure of the machine signal. Shall be marked on the nameplate manufacturer name and a registered trademark or identification mark, Chinese product name, specifications, manufacturing location, the only identifiable The content of the number, date of manufacture and so on. It should also be marked rated supply voltage range, rated frequency range other major electrical parameters. And electrical power supply device according 5.3
5.3.1 General requirements Signal layout and internal electrical components of the device should be reasonable, the operator in the installation, use, maintenance Security, convenience, all racks Installation of equipment to do the arrangement in the removal does not affect other nearby devices. Any electrical component mounting surface inside the outdoor unit distance from the bottom of the cabinet should be not less than 200mm.
5.3.2 Power Rated voltage of the main power signal. AC 220V ± 44V, 50Hz ± 2Hz.
5.4 The basic functional requirements
5.4.1 General requirements The basic functions of the signal following general requirements.
a) according to a predetermined display GB 14886 lights and light color conversion requirements, control the operating state lights;
b) inside the calendar clock signal, at 0 °C ~ 40 °C, error does not exceed ± 20s/10d;
c) absence of special provisions, the following signal period are lS adjustment step;
d) flashing yellow signal of a frequency of 55 to 65 times per minute, the signal light and dark time ratio of 1; flash signal wherein the tungsten lamp Allows to reduce the frequency, not less than 30 beats per minute, the light-dark signal is not greater than 1.1;
e) crosswalk lights flashing green signal frequency, with the ratio of the signal light and dark yellow flashing signal;
f) In the control mode switching, when the change timing scheme, the display state of the signal should be a smooth transition.
5.4.2 Start timing When the signal power starts running, self-test should be performed, and then start the following sequence.
a) phase should enter yellow flashing signal, at least the duration of 10s; After
b) yellow flashing red light...
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 24 pages — is available in the English PDF.
Referenced standards
Normative references
- GB 14886Specifications for road traffic signal setting and installation
- GB/T 17626.11Electromagnetic compatibility - Testing and measurement techniques - Part 11: Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
- GB/T 31418Terminology for road traffic signal control systems
GB/T 2423.1 · GB/T 2423.2 · GB/T 2423.3 · GB/T 2423.6 · GB/T 2423.10 · GB/T 2423.38 · GB 4943.1 · GB/T 17626.2 · GB/T 17626.4 · GB/T 17626.5 · GB/T 19520.1-2007
Editions of GB 25280
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB 25280-2016 | Road traffic signal controller | current edition | Current |
| GB 25280-2010 | Road traffic signal controller | previous edition | Superseded |
| GB/T 30502-2014 | Traffic Signal Controller for Lanes on Urban Road | merged into this edition | Superseded |
This page sells the current edition, GB 25280-2016. Earlier editions are listed for reference only.
How to Buy GB 25280-2016
- 1Add to cart. Click the "Buy GB 25280-2016" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 14886-2016 — Specifications for road traffic signal setting and installation
GB/T 17626.11-2023 — Electromagnetic compatibility - Testing and measurement techniques - Part 11: Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
GB/T 2423.101-2025 — Environmental testing - Part 2: Test methods - Test: Inclinations and swings
Secure payment via Stripe
Payments accepted
GB 25280-2016