YY/T 0967-2022Dentistry-Shanks for rotary and oscillating instruments (English PDF)
牙科学 旋转和往复运动器械的杆
This is a limited preview
Buy now to download the full PDF (22 pages)
Need quotation for your management?
Get a formal quotation for YY/T 0967-2022 in 30 minutes.
Issued by
NMPA
Level / Type
Industry · Recommended
Issue date
May 18, 2022
Implementation date
June 1, 2023
Scope
YY/T 0967-2022 is the English-translated version of 牙科学 旋转和往复运动器械的杆.
YY/T 0967-2022 is the Chinese pharmaceutical industry standard for the shanks of dental rotary and oscillating instruments, the ends by which a bur or a similar instrument is held in the handpiece.
It sets the dimensions and the material property requirements for these shanks, the measurement methods that verify them and the information by which a shank type is identified, so that instrument and handpiece fit together and run safely whoever made them.
It does not apply to tips that screw onto the handpiece, such as scaler tips. It replaces YY/T 0967.1-2015, was issued on 18 May 2022 and has applied since 1 June 2023.
Found what you need?
Document preview — YY/T 0967-2022
National Standard of the People's Republic of China
- Classification
- C 33
- Replacing
- YY/T 0967.1-2015
Issued by: National Medical Products Administration of the People's Republic of China
Contents
- Preface
- 1 Scope
- 2 Normative references
- 3 Terms, Definitions and Symbols
- 4 Category
- 5 Requirements
- 6 Sampling and pass/fail evaluation
- 7 Measurement and test methods
- Appendix A (Informative) Quality Control
- Reference
Foreword
This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1: Structure and Drafting Rules of Standardization Documents" drafted.
This document replaces YY/T 0967.1-2015 "Dental Rotary Instrument Rod Part 1: Metal Rod", YY/T 0967.2-2015 "Dental Rotary Instrument Rod Part 2: Plastic Rod", YY/T 0967.3-2016 "Dental Rotary Instrument Rod Part 3: Ceramic Rod". This document is compared with YY/T 0967.1-2015, YY/T 0967.2-2015, YY/T 0967.3-2016, except for structural adjustment and In addition to editorial changes, the main technical changes are as follows.
--- Changed the scope (see Chapter 1, Chapter 1 of the.2015 edition, Chapter 1 of the.2016 edition);
--- Added terms and definitions for mobile phones, instruments, reciprocating instruments, rotating instruments and mating lengths (see 3.1.1, 3.1.2, 3.1.3, 3.1.4, 3.1.6);
--- Changed the tensile strength of the plastic rod (see 5.2.3.2, 4.5 of the.2015 edition);
--- Added specific sampling and evaluation methods (see Chapter 6);
--- Increased the experimental method of resistance to expansion during repeated processing (see 7.7.3);
--- Changed the product defect as Appendix A (see Appendix A, Appendix A of the.2016 edition).
This document uses the redrafting method to amend ISO 1797:2017, Rods for Rotary and Reciprocating Instruments in Dentistry.
The technical differences between this document and ISO 1797:2017 and their reasons are as follows.
--- Regarding normative reference documents, this document has made adjustments with technical differences to adapt to the technical conditions of our country and facilitate this article.
According to the implementation of the document, the adjustment situation is mainly reflected in Chapter 2 "Normative Reference Documents", and the specific adjustment is as follows.
- Replace ISO 527-2 with GB/T 1040.2 which is equivalent to adopting international standards (see 7.6);
- Replace ISO 1101 with GB/T 1182 which is modified to adopt international standard (see 5.1.3);
- Replace ISO 6507-1 (see 7.5) with GB/T 4340.1 modified to adopt international standards;
- Replace ISO 3274 with GB/T 6062 which is equivalent to adopting international standards (see 7.4);
- Replace ISO 1942 with GB/T 9937 which is modified to adopt international standard (see 3.1);
- Replace ISO 4288 with GB/T 10610 which is equivalent to adopting international standards (see 7.4);
- Replacing ISO 8325 with YY/T 0874 which is equivalent to adopting international standards (see 7.1, 7.2);
- Replacing ISO 14457 with YY 1807 modified to adopt international standards (see 3.1);
- Replacing EN 843-4 with GB/T 16534 modified to adopt international standards (see 7.5);
--- Deleted "manufacturer" in 7.1 and 7.2, the manufacturer and inspection agency should verify whether the accuracy of the measuring device is applicable.
1 Scope
This document specifies the dimensions and material property requirements for the rods of dental rotary and reciprocating instruments and the measurement methods to verify these requirements and information identifying the location.
This document does not apply to tips that are threaded onto the handpiece, such as scaler tips.
2 Normative references
The contents of the following documents constitute essential provisions of this document through normative references in the text. Among them, dated citations documents, only the version corresponding to that date applies to this document; for undated references, the latest edition (including all amendments) applies to this document.
GB/T 1040.2 Determination of Tensile Properties of Plastics Part 2: Test Conditions for Molded and Extruded Plastics (GB/T 1040.2- 2006, ISO 527-2:1993, IDT)
GB/T 4340.1 Vickers Hardness Test for Metal Materials Part 1: Test Methods (GB/T 4340.1-2009, ISO 6507-1. 2005, MOD)
GB/T 6062 Product Geometric Specifications (GPS) Surface Structure Profile Method Contact (Stylus) Nominal Characteristics of Instruments (GB/T 6062-2009, ISO 3274:1996, IDT)
GB/T 9937 Dental Terminology (GB/T 9937-2020, ISO 1942:2009, MOD)
GB/T 10610 Product Geometric Specifications (GPS) Rules and Methods for Evaluating Surface Structure by Surface Structure Profile Method (GB/T 10610-2009, ISO 4288:1996, IDT)
GB/T 16534 Test method for hardness of fine ceramics at room temperature (GB/T 16534-2009, ISO 14705:2008, MOD)
YY/T 0874 Test methods for dental rotary instruments (YY/T 0874-2013, ISO 8325:2004, IDT)
YY 1807 Dental handpieces and motors (YY 1807-2022, ISO 14457:2017, MOD)
3 Terms, Definitions and Symbols
3.1 Terms and Definitions
The terms and definitions defined in GB/T 9937, YY 1807 and the following apply to this document.
3.1.1 Mobile phone handpiece
Powered hand-held instrument for driving a rotating or reciprocating instrument (3.1.3).
NOTE. This definition includes reciprocating (piston) instruments.
3.1.2 Instrument
Apparatus for rotating or reciprocating movement, including working part, neck (if applicable) and rod (3.1.5), constructed to fit the handpiece (3.1.1).
NOTE 1 This includes continuously rotating or reciprocating instruments (3.1.3).
Note 2.See Figure 1.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 22 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 1040.2Plastics – Determination of Tensile Properties – Part 2: Test Conditions for Moulding and Extrusion Plastics
- GB/T 4340.1Metallic materials - Vickers hardness test - Part 1: Test method
- GB/T 6062Geometrical product specifications (GPS) -- Surface texture: Profile method -- Nominal characteristic of contact (stylus) instruments
- GB/T 9937Dentistry - Vocabulary
- GB/T 10610Geometrical product specifications (GPS) -- Surface texture: Profile method -- Rules and procedures for the assessment of surface texture
- GB/T 16534Fine ceramics (advanced ceramics, advanced technical ceramics) -- Test method for hardness of monolithic ceramics at room temperature
YY 1807
Cited by
- YY/T 1972-2025Dentistry - Tissue punches
- YY/T 1978-2025Dentistry - Trephine burs
- GB/T 36917.2-2024Dentistry - Laboratory cutters - Part 2: Carbide laboratory cutters
- GB/T 44469-2024Dental rotary instruments - Laboratory abrasive instruments
- GB/T 36917.3-2022Dentistry - Laboratory cutters - Part 3: Carbide cutters for milling machines
- GB/T 36917.4-2022Dentistry - Laboratory cutters - Part 4: Miniature carbide laboratory cutters
Similar standards
Editions of YY/T 0967
| Edition | Title | Revision | Status |
|---|---|---|---|
| YY/T 0967-2022 | Dentistry-Shanks for rotary and oscillating instruments | current edition | Current |
| YY/T 0967.1-2015 | Dentistry-Shanks for rotary and oscillating instruments | previous edition | Superseded |
This page sells the current edition, YY/T 0967-2022. Earlier editions are listed for reference only.
How to Download YY/T 0967-2022
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 1040.2-2022 — Plastics – Determination of Tensile Properties – Part 2: Test Conditions for Moulding and Extrusion Plastics
GB/T 10610-2009 — Geometrical product specifications (GPS) -- Surface texture: Profile method -- Rules and procedures for the assessment of surface texture
GB/T 16534-2009 — Fine ceramics (advanced ceramics, advanced technical ceramics) -- Test method for hardness of monolithic ceramics at room temperature
Secure payment via Stripe
Payments accepted
YY/T 0967-2022
$180.00