JB/T 6758.4-2007Continuously transposed conductors - Part 4: Heat resistant continuously transposed conductors of enamelled copper wires (English PDF)
换位导线 第4部分:耐热型漆包换位导线
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for JB/T 6758.4-2007 in 30 minutes.
Issued by
MIIT
Level / Type
Industry · Recommended
Issue date
March 6, 2007
Implementation date
September 1, 2007
Scope
JB/T 6758.4-2007 is the English-translated version of 换位导线 第4部分:耐热型漆包换位导线.
JB/T 6758.4-2007 is the Chinese standard "Continuously transposed conductors - Part 4: Heat resistant continuously transposed conductors of enamelled copper wires".
Its scope clause reads: This Part of JB/T 6758 specifies the general requirements for heat resistant continuously transposed conductors of enamelled copper wires.
Such as polyester fiber non-woven fabric strip insulated Grade-155 modified polyester continuously transposed conductors of enamelled copper wire (referred to as non-woven fabric continuously transposed conductor); aromatic polyamide paper-insulated Grade-180 polyester imide or Grade-200 polyester imide/polyamideimide composite continuously transposed conductor of enamelled copper wire and semi-hard conductor (referred to as aromatic polyamide continuously transposed conductor), etc. Enamelled rectangular copper wire copper conductor can be either ordinary soft copper wire or semi-hard copper wire.
This Part shall be used in conjunction with JB/T 6758.1-2007. Its clauses include terms and definitions, code and product.
Found what you need?
Document preview — JB/T 6758.4-2007
National Standard of the People's Republic of China
Issued by: Ministry of Industry and Information Technology of the People's Republic of China
Contents
- Foreword3
- 1 Scope4
- 2 Normative References4
- 3 Terms and Definitions, Code and Product Presentation4
- 4 Models5
- 5 Specifications5
- 6 Technical Requirements, Test Method and Inspection Rules6
- 6.1 Size6
- 6.2 Material heat resistance and product structure6
- 6.3 Technical requirements and test methods6
- 6.4 Inspection rules7
1 Scope
This Part of JB/T 6758 specifies the general requirements for heat resistant continuously transposed conductors of enamelled copper wires. Such as polyester fiber non-woven fabric strip insulated Grade-155 modified polyester continuously transposed conductors of enamelled copper wire (referred to as non-woven fabric continuously transposed conductor); aromatic polyamide paper-insulated Grade-180 polyester imide or Grade-200 polyester imide/polyamideimide composite continuously transposed conductor of enamelled copper wire and semi-hard conductor (referred to as aromatic polyamide continuously transposed conductor), etc. Enamelled rectangular copper wire copper conductor can be either ordinary soft copper wire or semi-hard copper wire.
This Part shall be used in conjunction with JB/T 6758.1-2007.
2 Normative References
The provisions in following documents become the provisions of this Part through reference in this Part of JB/T 6758. For dated references, the subsequent amendments (excluding corrigendum) or revisions do not apply to this Standard, however, parties who reach an agreement based on this Standard are encouraged to study if the latest versions of these documents are applicable. For undated references, the latest edition of the referenced document applies.
GB/T 4074.2 Test Methods for Winding Wires - Part 2: Determination of
Dimensions (GB/T 4074.2-1999, idt IEC 60851-2:1996)
JB/T 6758.1-2007 Continuously Transposed Conductors - Part 1: General
Requirements
JB/T 6758.2-2007 Continuously Transposed Conductors - Part 2: Paper-Insulated
Continuously Transposed Conductors of Polyvinyl Acetal Enamelled Copper
Wires
3 Terms and Definitions, Code and Product
6.1 Size
The maximum shape size shall be no larger than the values calculated as per Formula (4) and Formula (5) in 4.4 of JB/T 6758.1-2007.
--- k1 = 1;
--- k2 = 1;
--- deltamax is maximum thickness of lapping insulated layer; its value and deviation can refer to Table 1 in JB/T6758.1-2007 or determined through the negotiation between the supplier and the purchaser;
--- Kh can refer to Table 2 in JB/T 6758.2-2007;
--- Kw = 0.15 mm;
--- when W2max and H2max are within the specified range, delta max is allowed to be out of tolerance.
6.2 Material heat resistance and product structure
The heat resistance of enamelled rectangular wire and lapping insulated paper shall be at least no less than the use requirements for heat resistance of continuously transposed conductor; when the contract is signed, the supplier and purchaser shall agree at the types of enamelled rectangular wire and insulated paper.
Insulation tape width, lapping pitch, lapping mode shall conform to the provisions of
Clause 4 in JB/T 6758.1-2007; or determined through the negotiation between the supplier and the purchaser.
6.3 Technical requirements and test methods
The technical requirements and test methods shall conform to the provisions of Table
2.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Similar standards
How to Download JB/T 6758.4-2007
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JB/T 6758.3-2007 — Continuously transposed conductors - Part 3: Paperless netting-bound polyvinyl acetal enamelled continuously transposed conductors
JB/T 6758.2-2007 — Continuously transposed conductors - Part 2: Paper-insulated continuously transposed conductors of polyvinyl acetal enamelled copper wires
JB/T 6758.1-2007 — Continuously transposed conductors - Part 1: General requirements
JB/T 6758.4-2007
$75.00