Scope

JB/T 6758.3-2007 is the English-translated version of 换位导线 第3部分:无纸捆绑型缩醛漆包换位导线.

JB/T 6758.3-2007 is the Chinese standard "Continuously transposed conductors - Part 3: Paperless netting-bound polyvinyl acetal enamelled continuously transposed conductors".

Its scope clause reads: This Part of JB/T 6758 specifies the general requirements for less paper insulated netting-typed continuous transposed conductors of polyvinyl acetal enamelled copper wires.

The continuous transpose conductor core adopts Grade-120 self-adhesive polyvinyl acetal enamelled rectangular copper wire (thermosetting epoxy resin self- adhesive layer); mesh rope netting type adopts polyester fiber rope netting; grid netting type adopts polyester fiber nonwoven strip, epoxy resin glass fiber cloth strip or perforated insulating paper strip lapping.

Copper conductor can be either ordinary soft copper wire or semi-hard copper wire. This Part shall be used in conjunction with JB/T 6758.1. Its clauses include terms and definitions, code and product; size.

Found what you need?

Document preview — JB/T 6758.3-2007

National Standard of the People's Republic of China

Issued by: Ministry of Industry and Information Technology of the People's Republic of China

Contents

  • Foreword3
  • 1 Scope4
  • 2 Normative References4
  • 3 Terms and Definitions, Code and Product Presentation4
  • 4 Models5
  • 5 Specifications5
  • 6 Technical Requirements, Test Methods and Inspection Rules5
  • 6.1 Size and structure6
  • 6.2 Technical requirements and test methods7
  • 6.3 Inspection rules7

1 Scope

This Part of JB/T 6758 specifies the general requirements for less paper insulated netting-typed continuous transposed conductors of polyvinyl acetal enamelled copper wires. The continuous transpose conductor core adopts Grade-120 self-adhesive polyvinyl acetal enamelled rectangular copper wire (thermosetting epoxy resin self- adhesive layer); mesh rope netting type adopts polyester fiber rope netting; grid netting type adopts polyester fiber nonwoven strip, epoxy resin glass fiber cloth strip or perforated insulating paper strip lapping. Copper conductor can be either ordinary soft copper wire or semi-hard copper wire.

This Part shall be used in conjunction with JB/T 6758.1.

2 Normative References

The provisions in following documents become the provisions of this Part through reference in this Part of JB/T 6758. For dated references, the subsequent amendments (excluding corrigendum) or revisions do not apply to this Standard, however, parties who reach an agreement based on this Standard are encouraged to study if the latest versions of these documents are applicable. For undated references, the latest edition of the referenced document applies.

GB/T 4074.2 Test Methods for Winding Wires – Part 2: Determination of

Dimensions (GB/T 4074.2-1999, idt IEC 60851-2:1996)

JB/T 6758.1-2007 Continuously Transposed Conductors – Part 1: General

Requirements

3 Terms and Definitions, Code and Product

6.1.2

The number of netting rope lapping, lapping direction, position of lining paper,

the number and thickness of lining paper layer shall be determined through the negotiation between the supplier and the purchaser.

6.1.3

The lapping mode of lapping strip and grid size shall be determined through the negotiation between the supplier and the purchaser.

6.2 Technical requirements and test methods

The technical requirements and test methods shall conform to the provisions of Table

3.

6.3 Inspection rules

The inspection rules shall conform to the provisions of Clause 6 in JB/T 6758.1-2007.

Table 3

SN Item Names

Technical Requirements

Test

Types

Test Methods

HKN HWN HWNC1,

HWNC2 or

HWNC3

HKNC1,

HKNC2

HKNC3 or

HUKNC1,

HUKNC2,

HUKNC3

1 Size

T, S

1.1 Size of enamelled rectangular

wire

4.1.2 in JB/T 6758.1-2007 GB/T 4074.2

1.2

Insulation thickness, number of layers

4.3 in JB/T 6758.1-2007

5.2.1 in JB/T

6758.1-2007 1.3 Intermediate lining paper width 4.2.3 in JB/T 6758.1-2007 Generally, use the steel rule with precision of 1mm to measure

1.4 Oil-channel size 6.1 in this Part

1.5 Shape size of continuously

transposed conductor

6.1 in this Part

5.2.2 in JB/T

6758.1-2007

2

Continuously transposed conductor core of enamelled rectangular wire

T, S

2.1 Transposition pitch 4.2.4 in JB/T 6758.1-2007 5.2.3 in JB/T

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Similar standards

How to Download JB/T 6758.3-2007

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JB/T 6758.3-2007

$35.00