JB/T 6758.1-2007Continuously transposed conductors - Part 1: General requirements (English PDF)

换位导线 第1部分:一般规定

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for JB/T 6758.1-2007 in 30 minutes.

Issued by

MIIT

Level / Type

Industry · Recommended

Issue date

March 6, 2007

Implementation date

September 1, 2007

Scope

JB/T 6758.1-2007 is the English-translated version of 换位导线 第1部分:一般规定.

JB/T 6758.1-2007 is the Chinese standard "Continuously transposed conductors - Part 1: General requirements". Its scope clause reads: This part of JB/T 6758 specifies the type, product variety structure, technical requirements, acceptance rules and packaging marking of the continuously transposed conductors.

This part shall be used in conjunction with the subsequent product standard parts of JB/T 6758. The continuously transposed conductor is applicable to the electrical windings of a variety of oil-immersed, dry-type transformers, and reactors, etc. Its clauses include packaging, marking and storage.

Found what you need?

Document preview — JB/T 6758.1-2007

National Standard of the People's Republic of China

Issued by: Ministry of Industry and Information Technology of the People's Republic of China

Contents

  • Foreword4
  • 1 Scope5
  • 2 Normative references5
  • 3 Terms and definitions, codes and product representations6
  • 3.1 Terms and definitions6
  • 3.2 Symbols8
  • 3.3 Code9
  • 3.4 Product model10
  • 3.5 Product expression method12
  • 4 Technical requirements13
  • 4.1 Materials13
  • 4.2 Transposed core structure14
  • 4.3 Lapping insulation layer16
  • 4.4 Maximum dimensions of continuously transposed conductors18
  • 4.5 Welding18
  • 4.6 DC voltage resistance19
  • 4.7 Conductor path19
  • 4.8 Bond strength19
  • 4.9 Delivery length19
  • 5 Test methods20
  • 5.1 General20
  • 5.2 Dimensional measurements20
  • 5.3 DC voltage resistance test21
  • 5.4 Conductor path test21
  • 5.5 Bond strength test21
  • 5.6 Test of specified non-proportional extension strength Rp0.222
  • 5.7 Delivery length22
  • 6 Inspection rules22
  • 7 Packaging, marking and storage23
  • 7.1 Packaging23
  • 7.2 Marking23
  • 7.3 Storage23
  • Appendix A (Informative) High elongation fiber paper25
  • Appendix B (Informative) Aromatic polyamide paper26
  • Appendix C (Informative) Heat-resistant electrical milk white glue27

1 Scope

This part of JB/T 6758 specifies the type, product variety structure, technical requirements, acceptance rules and packaging marking of the continuously transposed conductors.

This part shall be used in conjunction with the subsequent product standard parts of JB/T 6758.

The continuously transposed conductor is applicable to the electrical windings of a variety of oil-immersed, dry-type transformers, and reactors, etc.

2 Normative references

The provisions in following documents become the provisions of this part through reference in this part of JB/T 6758. For the dated references, the subsequent amendments (excluding corrections) or revisions do not apply to this part; however, parties who reach an agreement based on this part are encouraged to study if the latest versions of these documents are applicable.

For undated references, the latest edition of the referenced document applies.

GB/T 228 Metallic materials - Tensile testing at ambient temperature (GB/T 228-2002, eqv ISO 6892:1998 (E))

GB/T 3048.14 Electric cables and wires - Method for D.C. voltage test (GB/T 3048.14-1992, neq ISO 060. 1 ~ 60.4:1973)

GB/T 4074.1 Test method for winding wires - Part 1: General (GB/T 4074.1-1999. Idt IEC 60851-1:1996)

GB/T 7095.2 Enameled rectangular wires - Part 2: Polyvinyl acetal enameled rectangular copper wires class 120 (GB/T 7095.2-1995, eqv IEC 60317-18:1990)

GB/T 7095.3 Enameled rectangular wires - Part 3: Polyester enameled rectangular copper wires with a temperature index of 155 (GB/T 7095.3-1995, eqv IEC 60317-16:1990)

GB/T 7095.4 Enameled rectangular wires - Part 4: Enameled rectangular copper wires with a temperature index of 180 (GB/T 7095.4-1995, eqv IEC 60317-28:1990)

GB/T 7095.6 Enameled rectangular wires - Part 6: Polyester (imide) over-coated with polyamide-imide enameled rectangular copper wires, class

200 (GB/T 7095.6-1995, eqv IEC 60317-29:1990)

GB 7969 Electric power cable paper (GB 7969-2003, IEC 60554-3-1:1979,

NEQ)

JB/T 9554 Electrical polyester non-woven fabric

QB/T 3521 500kV transformer coil winding paper

3 Terms and definitions, codes and product representations

3.1 Terms and definitions

The following terms and definitions apply to this standard.

3.1.1 Continuously transposed conductor

It refers to the winding conductors formed by two rows of a certain number of enameled copper (aluminum) flat wires mutually contacted at wide surfaces, transposed in same direction along the narrow surface of the top and below of the two rows of enameled flat wires, and lapped continuously by electrical insulated paper, rope or belt.

3.1.2 Transposition pitch

It refers to the axial length of a certain enameled flat wire in the continuously transposed conductor after subjected to a complete transposition cycle divided by the number of enameled flat wires of the continuously transposed conductor, that is, the axial length between two adjacent transpositions.

3.1.3 Overlapping
3.4.3 Heat-resistant enameled continuously transposed conductor

Polyester fiber non-woven fabric insulation 155 grade modified polyester enameled continuously transposed conductor: HFZG Polyester fiber non-woven fabric insulation 155 grade modified polyester enameled continuously transposed semi-hard conductor: HFZGC1, HFZGC2 or HFZGC3

Aromatic polyamide paper insulation 180 grade polyester imine continuously transposed conductor: HXZY Aromatic polyamide paper insulation 180 grade polyester imine continuously transposed semi-hard conductor: HXZYC1, HXZYC2 or HXZYC3

Aromatic polyamide paper insulation 200 grade polyester imine/polyamide imide composite continuously transposed conductor: HX (ZY/XY)

Aromatic polyamide paper insulation 200 grade polyester imine/polyamide imide composite continuously transposed semi-hard conductor: HX (ZY/XY)C1, or HX (ZY/XY)C2, or HX (ZY/XY)C3

3.5 Product expression method

3.5.1

Product is expressed in model, conductor dimension, number of transposed core, insulation nominal thickness, maximum dimensions and the number of this standard, that is, product model a × b/n - delta (H2max/W 2max) JB/T 6758.1-2007.

3.5.2

Examples of product expression methods are as follows:

Example 1: Conductor a × b is the 120 grade acetal enameled flat wire of 1.60 mm × 6.30 mm, 27 wires, high density insulation paper insulation, nominal insulation thickness 1.35 mm (maximum dimensions H 2max × W 2max) paper insulation self-adhesive acetal enameled continuously transposed semi-hard conductor (C2 grade) is expressed as:

HMNC2 1.60 × 6.30/27 - 1.35 (H2max × W 2max ) JB/T 6758.2-2007.

4.1.3 Insulation paper

Insulation paper for paper insulated continuously transposed conductors has the following types:

a) Power cable paper shall comply with the provisions of GB 7969:

b) The specifications, thickness and technical requirements for the electrical polyester fiber nonwoven fabrics shall comply with the provisions of JB/T 9554:

c) The performance of the high-elongation fiber paper the high thickness of two thicknesses is as shown in Appendix A; AND the technical requirements shall be specified by the supplier and the purchaser through negotiation;

d) The performance of the aromatic polyamide paper is as shown in

Appendix B; AND the technical requirements shall be specified by the supplier and the purchaser through negotiation;

e) The 500kV transformer inter-turn insulation paper shall comply with the requirements of QB/T 3521; AND the technical requirements for other high density crepe paper shall be specified by the supplier and the purchaser through negotiation;

f) Other insulation paper is as negotiated by the supplier and the purchaser.

4.1.4 Binding rope or tape

The technical requirements for polyester fiber binding rope and mesh binding tape (polyester fiber nonwoven tape, epoxy fiberglass tape or perforated paper tape) shall be specified by the supplier and the purchaser through negotiation.

4.2 Transposed core structure

4.2.1 Number of transposed core

The number of transposed core is as follows:

4.3.3

The paper tape shall be of appropriate density AND evenly and smoothly

lapped around the transposed core, AND the paper tape shall be free from such defects as missing layer, wrinkles or cracking.

4.3.4

For paperless binding type continuously transposed conductor, the supplier and the purchaser shall define the backing paper thickness and the backing location.

4.3.5

Each layer of insulation paper is generally in overlapping, the width of overlapping of the paper tape shall be not less than 2 mm, the overlapping portions of the adjacent two layers of paper shall be uniformly staggered, AND the paper tape width is generally no exceeding 35 mm. The lapping pitch can be determined by the supplier and the purchaser through negotiation.

4.3.6

As required by the user, it may use partial or total open lapping at the middle to replace the overlapping. The width of open lapping shall be not more than 2 mm, the lapping gaps shall be uniformly staggered from each other,

AND the number of coincidence of butt gaps shall not exceed 1 per every 8 layers.

4.3.7

During overlapping, it generally use the lapping along same direction,

BUT it is also allowed to conduct lapping along different directions; during open lapping, if the number of paper tape layers does not exceed 8, it shall use lapping along same direction; if the number of paper tape layers exceed 8, it shall change the lapping direction, AND at this time it shall avoid the continuously coincidence of the lapping gap.

5.2.4

Measurement of width of open lapping, width of overlapping, and

lapping pitch

TAKE a sample of about 500 mm length; USE the steel ruler of a precision not less than 0.5 mm to directly measure the width of open lapping, width of overlapping, and lapping pitch, one measurement at each layer, accurate to 1 mm.

5.3 DC voltage resistance test

5.3.1 Test voltage

DC 500V and pulsation factor is not more than 5%.

5.3.2 Test equipment

The test equipment consists of components such as not less than 500 VA transformers, rectifier components, filter capacitors, voltmeter, and breakdown indicator AND connection cables. The test equipment shall comply with the relevant provisions of GB/T 3048.14. When the breakdown current is greater than or equal to 20 mA, the equipment shall indicate breakdown.

5.3.3 Test procedures

At one end of a whole coil of continuously transposed conductor, in between the adjacent enameled flat wires, APPLY 500 V DC voltage for not less than 5 s, AND there shall be no breakdown between wires. USE this method to consecutively measure the adjacent enameled flat wires, until all the enameled flat wire measurement is completed.

5.4 Conductor path test

USE the x1 or x10 position of the resistor “ohm” end of the multimeter AND the measurement rod to measure the both ends of the same enameled flat wire in turn, AND there shall be no open circuit, until all the enameled flat line measurement is completed.

5.5 Bond strength test

5.5.1 Enameled flat wire bond strength test

From the continuously transposed conductor sample, TAKE two straight enameled flat wires of length about 110 mm, 5 groups in total; as shown in […]

6.3

As for the sampling test, if the test results of the first time are disqualified, it

shall double the samples to conduct the second test; if it is still disqualified, it shall conduct 100% test.

6.4

The quantity of samples taken from each batch of products shall be provided by the agreement between the supplier and the purchaser; BUT it shall be not less than two coils.

7 Packaging, marking and storage

7.1 Packaging

7.1.1

The continuously transposed conductors shall be delivered in packaged coil, the finished products shall be tightly, uniformly and neatly around the wire coil, in between layers shall be separated by the application of the entire protective paper, AND the distance from the outermost layer to the cable coil edge shall be not less than 30 mm.

7.1.2

The wire coil with finished products shall be wrapped by moisture-proof and anti-bump material, AND the both ends of the continuously transposed conductors shall be fastened to the wire coil.

7.2 Marking

Each coil of finished product shall have label, indicating:

a) Manufacturer name, trademark or certification mark;

b) Product model, specifications, number, nominal thickness of insulation layer, product dimensions, and standard number;

c) Length, in m;

d) Net weight and gross weight, in kg;

e) Date of manufacture.

7.3 Storage

7.3.1

The finished product shall be stored in a clean, dry, and well ventilated warehouse with a temperature of (-20 ~ 35) °C.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download JB/T 6758.1-2007

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included