JB/T 6758.2-2007Continuously transposed conductors - Part 2: Paper-insulated continuously transposed conductors of polyvinyl acetal enamelled copper wires (English PDF)
换位导线 第2部分:纸绝缘缩醛漆包换位导线
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for JB/T 6758.2-2007 in 30 minutes.
Issued by
MIIT
Level / Type
Industry · Recommended
Issue date
March 6, 2007
Implementation date
September 1, 2007
Scope
JB/T 6758.2-2007 is the English-translated version of 换位导线 第2部分:纸绝缘缩醛漆包换位导线.
JB/T 6758.2-2007 is the Chinese standard "Continuously transposed conductors - Part 2: Paper-insulated continuously transposed conductors of polyvinyl acetal enamelled copper wires".
Its scope clause reads: This Part of JB/T 6758 specifies the general requirements for paper-insulated continuous transposed conductors of polyvinyl acetal enamelled copper wires.
The enamelled rectangular wire can be Grade-120 polyvinyl acetal enamelled rectangular copper wire, or self-adhesive polyvinyl acetal enamelled rectangular copper wire coated with thermosetting epoxy resin on its outside; the copper conductor can be either conventional soft copper wire, or semi-hard copper wire.
This Part shall be used in conjunction with JB/T 6758.1. The paper-insulated continuous transposed conductors of polyvinyl acetal enamelled copper wires are applicable to the winding coils for oil-immersed type transformers or electrical appliances. Its clauses include terms and definitions, code and product; lapping.
Found what you need?
Document preview — JB/T 6758.2-2007
National Standard of the People's Republic of China
- Replacing
- JB/T 6758-1993
Issued by: Ministry of Industry and Information Technology of the People's Republic of China
Contents
- Foreword3
- 1 Scope5
- 2 Normative References5
- 3 Terms and Definitions, Code and Product Presentation5
- 4 Models6
- 5 Specifications6
- 6 Technical Requirements, Test Methods and Inspection Rules6
- 6.1 Size6
- 6.2 Technical requirements and test methods7
- 6.3 Inspection rules7
1 Scope
This Part of JB/T 6758 specifies the general requirements for paper-insulated continuous transposed conductors of polyvinyl acetal enamelled copper wires. The enamelled rectangular wire can be Grade-120 polyvinyl acetal enamelled rectangular copper wire, or self-adhesive polyvinyl acetal enamelled rectangular copper wire coated with thermosetting epoxy resin on its outside; the copper conductor can be either conventional soft copper wire, or semi-hard copper wire. This Part shall be used in conjunction with JB/T 6758.1.
The paper-insulated continuous transposed conductors of polyvinyl acetal enamelled copper wires are applicable to the winding coils for oil-immersed type transformers or electrical appliances.
2 Normative References
The provisions in following documents become the provisions of this Part through reference in this Part of JB/T 6758. For dated references, the subsequent amendments (excluding corrigendum) or revisions do not apply to this Standard, however, parties who reach an agreement based on this Standard are encouraged to study if the latest versions of these documents are applicable. For undated references, the latest edition of the referenced document applies.
GB/T 4074.2 Test Methods for Winding Wires – Part 2: Determination of
Dimensions (GB/T 4074.2-1999, idt IEC 60851-2:1996)
JB/T 6758.1-2007 Continuously Transposed Conductors – Part 1: General
Requirements
3 Terms and Definitions, Code and Product
1.4 Shape size of continuously
transposed conductor
6.1 in this Part
5.2.2 in JB/T
6758.1-2007
2
Continuously transposed conductor core of enamelled rectangular wire
T, S2.1 Transposition pitch 4.2.4 in JB/T 6758.1-2007
5.2.3 in JB/T
6758.1-2007
2.2
The number and shape of continuously transposed conductor core
6.1 in this Part; 4.2.1 and 4.2.6 in JB/T
6758.1-2007
Normal vision
3 Lapping
3.1 Lapping mass 4.3.3 in JB/T 6758.1-2007 T, S Normal vision
3.2 Gap width, gap overlap 4.3.6 in JB/T 6758.1-2007 T, S
5.2.4 in JB/T
6758.1-20073.3
Overlap lapping, semi-overlap lapping, overlap width, lapping pitch
4.3.5 in JB/T 6758.1-2007 T, S
3.4 Lapping direction 4.3.7 in JB/T 6758.1-2007 T, S Normal vision
4 Welding 4.5 in JB/T 6758.1-2007 T, S
Normal vision, micrometer or steel ruler with precision of 0.01mm
5 Withstand DC Voltage Test 4.6 in JB/T 6758.1-2007 T, R
5.3 in JB/T 6758.1-
2007
6 Conductor channel test 4.7 in JB/T 6758.1-2007 T, R
5.4 in JB/T 6758.1-
2007
7.1 Bonding strength test ---
4.8.1 in JB/T
6758.1-2007
T, S
5.5.1 in JB/T
6758.1-2007
7.2 Bonding bend test ---
4.8.2 in JB/T
6758.1-2007
5.5.2 in JB/T
6758.1-2007
8
Prescribed non-proportional elongation strength Rp0.2
---
4.1.1 in JB/T
6758.1-2007
--- T, S
5.6 in in JB/T
6758.1-2007
9 Delivery length 4.9 in JB/T 6758.1-2007 T, R
5.7 in JB/T 6758.1-
2007
10 Package, label Clause 7 in JB/T 6758.1-2007 T, R Normal vision
__________ END __________ […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Similar standards
Editions of JB/T 6758.2
| Edition | Title | Revision | Status |
|---|---|---|---|
| JB/T 6758.2-2007 | Continuously transposed conductors - Part 2: Paper-insulated continuously transposed conductors of polyvinyl acetal enamelled copper wires | current edition | Current |
| JB/T 6758-1993 | Continuously transposed conductors - Part 2: Paper-insulated continuously transposed conductors of polyvinyl acetal enamelled copper wires | previous edition | Superseded |
This page sells the current edition, JB/T 6758.2-2007. Earlier editions are listed for reference only.
How to Download JB/T 6758.2-2007
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JB/T 6758.3-2007 — Continuously transposed conductors - Part 3: Paperless netting-bound polyvinyl acetal enamelled continuously transposed conductors
JB/T 6758.1-2007 — Continuously transposed conductors - Part 1: General requirements
JB/T 6758.4-2007 — Continuously transposed conductors - Part 4: Heat resistant continuously transposed conductors of enamelled copper wires
JB/T 6758.2-2007
$75.00