GB/T 8801-2007Test method for unplasticized polyvinyl chloride(PVC-U)fittings by falling (English PDF)
硬聚氯乙烯(PVC-U)管件坠落试验方法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 8801-2007 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
December 5, 2007
Implementation date
September 1, 2008
Scope
GB/T 8801-2007 is the English-translated version of 硬聚氯乙烯(PVC-U)管件坠落试验方法.
GB/T 8801-2007 is the Chinese national drop test for unplasticized polyvinyl chloride (PVC-U) fittings. A fitting is conditioned at (0 ± 1) °C, then dropped freely within 10 s onto a flat concrete floor and examined for damage.
The standard fixes the apparatus - a stopwatch reading 0.1 s, an ice-water bath or cryogenic box at (0 ± 1) °C - and the samples: complete injection-moulded fittings, any elastic seal removed, at least five per specification.
Its foreword gives the drop heights by nominal diameter: (2.00 ± 0.05) m up to 75 mm, (1.00 ± 0.05) m above 75 mm and below 200 mm, and (0.50 ± 0.05) m at 200 mm and above.
It applies to PVC-U fittings. It replaces GB 8801-1988, was issued on 5 December 2007 and has applied since 1 September 2008.
Found what you need?
Document preview — GB/T 8801-2007
National Standard of the People's Republic of China
- ICS
- 83.140.30
- Classification
- G 33
- Replacing
- GB 8801-1988
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword3
- 1 Scope4
- 2 Principle4
- 3 Instruments and apparatuses4
- 4 Test sample and its preparation4
- 5 Test conditions4
- 6 Test steps5
- 7 Result judgment5
- 8 Test report6
Foreword
This Standard closely combines domestic plastic product developments, and refers to technical contents of relevant domestic standards, to amend GB/T 8801-1988 "Test method for unplasticized PVC fittings by falling".
This Standard replaces GB/T 8801-1988 "Test method for unplasticized PVC fittings by falling". Compared with the latter, the main change is the division of the requirements for the falling height:
-- Fittings, whose nominal diameter is less than or equal to 75 mm, fall from (2.00 ± 0.05) m above the ground;
-- Fittings, whose nominal diameter is greater than 75 mm and less than 200 mm, fall from (1.00 ± 0.05) m above the ground;
-- Fittings, whose nominal diameter is equal to or greater than 200 mm, fall from (0.50 ± 0.05) m above the ground.
1 Scope
This Standard specifies the test method for unplasticized polyvinyl chloride (PVC-U) fittings by falling.
This Standard applies to various uses of unplasticized polyvinyl chloride (PVC- U) fittings.
2 Principle
In this method, pretreat the fitting at (0 ± 1) °C for a prescribed period of time; let it freely fall from a prescribed height to a flat concrete floor within 10 s; observe the damage of the fitting.
3 Instruments and apparatuses
3.1 Stopwatch: the division value is 0.1 s.
3.3 Constant-temperature water bath (ice water mixture inside) or cryogenic box: the temperature is (0 ± 1) °C.
3.2 Thermometer: the division value is 1 °C
4 Test sample and its preparation
4.1 The test sample is a complete fitting of injection molding. If the fitting is equipped with an elastic seal, it shall be removed before testing. If the fitting consists of more than one injection-molded parts, these parts shall be tested separately from each other.
4.2 The number of test samples shall be in accordance with the product standards. For the same batch of products of the same specification, at least take 5 test samples. The test samples shall be free of mechanical damage. […]
5 Test conditions
5.1 Falling height
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Cited by
- GB/T 45232-2025Polypropylene(PP) piping systems for drainage and sewerage inside buildings
- GB/T 45355-2025Polyethylene(PE) piping systems for non-pressure buried drainage and sewerage
- GB/T 45356-2025Polypropylene(PP) piping systems for non-pressure buried drainage and sewerage
- GB/T 44574-2024Plastic check valves for anti-pollution for discharge piping systems inside buildings
- GB/T 44579-2024Water distribution and collection devices of thermoplastics materials
- GB/T 10002.2-2023Unplasticized poly (vinyl chloride) (PVC-U) fittings for water supply
Similar standards
Editions of GB/T 8801
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB/T 8801-2007 | Test method for unplasticized polyvinyl chloride(PVC-U)fittings by falling | current edition | Current |
| GB 8801-1988 | Test method for unplasticized polyvinyl chloride(PVC-U)fittings by falling | previous edition | Superseded |
This page sells the current edition, GB/T 8801-2007. Earlier editions are listed for reference only.
How to Download GB/T 8801-2007
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 10004-2026 — Plastic/Plastic laminated films and pouches for packaging
GB/T 10007-2026 — Rigid cellular plastics - Determination of shear properties
Secure payment via Stripe
Payments accepted
GB/T 8801-2007
$85.00