GB/T 6113.102-2018Specification for radio disturbance and immunity measuring apparatus and methods -- Part 1-2: Radio disturbance and immunity measuring apparatus -- Coupling devices for conducted disturbance measurements (English PDF)
无线电骚扰和抗扰度测量设备和测量方法规范 第1-2部分:无线电骚扰和抗扰度测量设备 传导骚扰测量的耦合装置
This is a limited preview
Buy now to download the full PDF
Need quotation for your management?
Get a formal quotation for GB/T 6113.102-2018 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
July 13, 2018
Implementation date
February 1, 2019
Scope
GB/T 6113.102-2018 is the English-translated version of 无线电骚扰和抗扰度测量设备和测量方法规范 第1-2部分:无线电骚扰和抗扰度测量设备 传导骚扰测量的耦合装置.
GB/T 6113.102-2018 — This part of the GB/T 6113 series specifies the characteristics and performance of equipment for the measurement of radio disturbance voltages and currents in the frequency range 9 kHz ~ 1 GHz.
Found what you need?
Document preview — GB/T 6113.102-2018
National Standard of the People's Republic of China
Issued by: SAMR; SAC
Contents
- FOREWORD...4
- 1 Scope...7
- 2 Normative references...7
- 3 Terms, definitions and abbreviations...8
- 3.1 Terms and definitions...8
- 3.2 Abbreviations...11
- 4 Artificial mains networks...12
- 4.1 General...12
- 4.2 AMN impedance...12
- 4.3 50 ohm/50 µH + 5 ohm artificial mains V-network (V-AMN) (applicable to 9 kHz ~150
- kHz)...13
FOREWORD
GB/T6113 "Specification for radio disturbance and immunity measuring apparatus and
methods", a basic standard of electromagnetic compatibility, consists of the following
four parts.
Part 1.Radio disturbance and immunity measuring apparatus
-- Part 1-1.Radio disturbance and immunity measuring apparatus - Measuring
equipment;
-- Part 1-2.Radio disturbance and immunity measuring apparatus - Coupling devices
for conducted disturbance measurements;
-- Part 1-3.Radio disturbance and immunity measuring apparatus - Ancillary
equipment - Disturbances power;
-- Part 1-4.Radio disturbance and immunity measuring apparatus - Radiated
disturbance measuring antenna and test site;
-- Part 1-5.Radio disturbance and immunity measuring apparatus - Antenna
calibration sites and reference test sites for 30 MHz to 1000 MHz
-- Part 1-6.Radio disturbance and immunity measuring apparatus - EMC antenna
calibration.
Part 2.Methods of measurement of disturbances and immunity
-- Part 2-1.Methods of measurement of disturbances and immunity - Conducted
disturbance measurements;
-- Part 2-2.Methods of measurement of disturbances and immunity - Measurement
of disturbance power;
-- Part 2-3.Methods of measurement of disturbances and immunity - Radiated
disturbance measurements
-- Part 2-4.Methods of measurement of disturbances and immunity - Immunity
measurements;
-- Part 2-5.In situ measurements of disturbing emissions produced by physically
large equipment
Part 3.CISPR technical reports
-- Part 3.CISPR technical reports.
Part 4.Uncertainties, statistics and limit modelling
-- Part 4-1.Uncertainties, statistics and limit modelling - Uncertainties in
standardized EMC tests;
-- Part 4-2.Uncertainties, statistics and limit modelling - Measurement
instrumentation uncertainty;
-- Part 4-3.Uncertainties, statistics and limit modelling - Statistical considerations
in the determination of EMC compliance of mass-produced products;
-- Part 4-4.Uncertainties, statistics and limit modelling - Statistics of complaints and
a model for the calculation of limits;
-- Part 4-5.Uncertainties, statistics and limit modelling - Conditions for the use of
alternative test methods.
This Part is Part 1-2 of GB/T 6113.
This Part was drafted in accordance with the rules given in GB/T 1.1-2009.
This Part replaces GB/T 6113.102-2008 "Specification for radio disturbance and
immunity measuring apparatus and methods - Part 1-2.Radio disturbance and
immunity measuring apparatus - Ancillary equipment - Conducted disturbances".
Compared with GB/T 6113.102-2008, the main technical changes are as follows.
-- Modify the standard's name;
-- Add a "Note" to the scope according to the principle of equivalence;
-- Add 7 terms and definitions (see Clause 3);
-- Add abbreviations (see 3.2);
-- Add longitudinal conversion loss requirements for AAN (or Y-network) for
common-mode voltage measurement of category 6 (or better), category 5 (or
better), and category 3 (or better) unscreened balanced pair cables (see 7.2);
-- Add CDNE for the measurement of disturbance voltage in the frequency range of
30 MHz ~ 300 MHz (see Clause 9);
-- Add Example CDNE set-up diagrams (see Annex J).
This Part uses the translation method to equivalently adopt CISPR 16-1-2.2014
"Specification for radio disturbance and immunity measuring apparatus and methods -
Part 1-2.Radio disturbance and immunity measuring apparatus - Coupling devices for
conducted disturbance measurements".
The documents of our country that have a consistent correspondence with the
international documents that are referenced in this Part are as follows.
-- GB/T 4365-2003 Electrotechnical terminology - Electromagnetic compatibility
(IEC 60050(161).1990, IDT);
-- GB/T 6113.201-2017 Specification for radio disturbance and immunity measuring
apparatus and methods - Part 2-1.Methods of measurement of disturbances and
immunity - Conducted disturbance measurements (CISPR 16-2-1.2010, IDT);
-- GB/T 17626.6-2008, Electromagnetic compatibility - Testing and measurement
techniques - Immunity to conducted disturbances induced by radio-frequency
fields (IEC 61000-4-6.2006, IDT).
This Part shall be under the jurisdiction of National Technical Committee 79 on Radio
Jamming of Standardization Administration of China (SAC/TC 79).
The drafting organizations of this Part. China Electronics Standardization Institute, The
Fifth Institute of Electronics, Ministry of Industry and Information Technology, Suzhou
3ctest Electronic Co., LTD, China National Accreditation Service for Conformity
Assessment, National Institute of Metrology, China, Southeast University, Beijing
Radio Measurement and Testing Institute, China Automotive Engineering Research
Institute Co., Ltd, Shaanxi Hitech Electronic Co., Ltd., Nanjing Rongxiang Testing
Equipment Co., Ltd., China Quality Certification Center, Shanghai Electrical Apparatus
Research Institute Group Company Limited, Beijing Zunguan Technology Co., Ltd.,
Dalian Product Quality Inspection Institute, Shanghai Electric Power Transportation
and Distribution Testing Centre Co., Ltd., Beijing Daze Technology Co., Ltd.
The drafters of this Part. Cui Qiang, Zhu Liwen, Liu Jia, Hou Xinwei, Ye Chang, Xie
Ming, Zhou Zhongyuan, Yao Lijun, Lai Zhida, Guo Enquan, Zhang Xia, Jin Dong, Cai
Huaqiang, Hu Xiaojun, Ye Qiongyu, Wang Zheng, Chen Yan, Xu Dan, Guo Liping, Li
Lijia.
The previous version of the standard which is replaced by this Part is.
-- GB/T 6113.102-2008.
Specification for radio disturbance and immunity measuring
apparatus and methods - Part 1-2.Radio disturbance and
immunity measuring apparatus - Coupling devices for
conducted disturbance measurements
1 Scope
This part of the GB/T 6113 series specifies the characteristics and performance of
equipment for the measurement of radio disturbance voltages and currents in the
frequency range 9 kHz ~ 1 GHz.
2 Normative references
The following referenced documents are indispensable for the application of this
document. For dated references, only the edition cited applies. For undated references,
the latest edition of the referenced document (including any amendments) applies.
3 Terms, definitions and abbreviations
radio-frequency disturbance voltage appearing between the two wires in a two-wire
circuit, such as a single-phase mains supply, sometimes called the differential mode
4 Artificial mains networks
The network shall have an impedance of magnitude (150 +/- 20) ohm with a phase angle
not exceeding 20°, both between the equipment terminals and between the two
equipment terminals joined together and the reference ground.
For the measurement of the symmetric voltage, a screened and balanced transformer is
5 Current and voltage probes
The current probe shall be constructed so as to enable the measurement of the current
without disconnecting the lead under measurement.
6 Coupling units for conducted current immunity measurement
The insertion loss VG/VB of two identical coupling units measured according to the
setup of Figure 9 should be within 9.6 dB and 12.6 dB in the frequency range 30 MHz
~ 150 MHz; VG is the reading of the receiver when the generator and receiver are
directly connected together; VB is the reading obtained from the measuring receiver
after inserting the coupling unit.
7 Coupling devices for measuring signal lines
AANs are used to measure (or inject) asymmetric (common mode) voltages on
unshielded symmetric signal (e.g., telecommunication) lines while rejecting the
symmetric (differential mode) signal.
8 The artificial hand and series RC element
The artificial hand consists of a (strip of) metal foil of specified dimensions, which is
placed on or wrapped around that part of the equipment normally touched by the user's
hand, in a specific configuration, described as follows.
The lead length between the RC element and the metal foil shall be 1 m. If the test set-
up requires a longer lead length, the total inductance of the lead shall be less than 1.4
µH if the frequency of measurement is near 30 MHz.
9 CDNE for measurement of disturbance voltage in frequency range 30 MHz ~ 300 MHz
The CDNE allows measurement of the asymmetric disturbance voltage Vdis generated
by the EUT on the connected cable(s).
The CDNE is contained in a metallic case. The centre of the CDNE EUT port is 30 mm
0 mm above the RGP. This height allows for a typical impedance of 150 ohm for the
connected cable.
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.
Referenced standards
Cited by
- GB/T 7260.2-2026Uninterruptible power systems (UPS) - Part 2: Electromagnetic compatibility (EMC) requirements
- GB/T 18655-2025Vehicles, boats and internal combustion engines - Radio disturbance characteristics - Limits and methods of measurement for the protection of on-board receivers
- GB/T 6113.203-2025Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements
- GB 4343.1-2024Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission
- GB/T 6113.106-2024Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-6: Radio disturbance and immunity measuring apparatus - EMC antenna calibration
- GB/T 7256.2-2023Lighting fixtures for civil airport—Part 2: Sequence flashing light and runway threshold identification light
How to Download GB/T 6113.102-2018
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 6113.101-2021 — Specification for radio disturbance and immunity measuring apparatus and methods—Part 1-1: Radio disturbance and immunity measuring apparatus—Measuring apparatus
GB/T 6113.102-2025 — Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-2: Radio disturbance and immunity measuring apparatus - Coupling devices for conducted disturbance measurements
GB/T 6113.103-2021 — Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-3: Radio disturbance and immunity measuring apparatus - Ancillary equipment - Disturbances power
Secure payment via Stripe
Payments accepted
GB/T 6113.102-2018
$830.00