GB/T 37139-2018Requirements for EMC measurement methods for DC powered equipment (English PDF)
直流供电设备的EMC测量方法要求
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 37139-2018 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
December 28, 2018
Implementation date
July 1, 2019
Scope
GB/T 37139-2018 is the English-translated version of 直流供电设备的EMC测量方法要求.
GB/T 37139-2018 sets the electromagnetic compatibility requirements that measurement methods must meet for equipment powered through a DC power port.
It covers equipment rating, measurement conditions, the product documentation to be supplied, applicability, emission and immunity requirements, measurement uncertainty, compliance of emission measurements and the performance criteria for immunity tests, and it states the test requirements and methods for each port considered.
It applies to equipment with a DC power port as defined in clause 3.1.5 and a rated voltage not above 1500 V DC, where no product or product family EMC standard exists.
It relies on the GB/T 6113 series for disturbance measurement and on the GB/T 17626 series for immunity tests. It was issued on 28 December 2018 and has applied since 1 July 2019.
Found what you need?
Document preview — GB/T 37139-2018
National Standard of the People's Republic of China
- ICS
- 33.100
- Classification
- L 06
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Terms and definitions, abbreviations
- 4 Equipment rating
- 5 Measurement conditions
- 6 Product Documentation
- 7 Applicability
- 8 Launch and immunity requirements
- 9 Measurement uncertainty
- 10 Standard compliance for emission measurements
- 11 immunity test performance criterion
- Reference
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
1 Scope
This standard specifies the electromagnetic compatibility (EMC) requirements for DC power supply equipment, including equipment grading, measurement conditions, product documentation, and Requirements for usability, emission and immunity requirements, measurement uncertainty, standard compliance for emission measurements, and immunity test performance criteria.
This standard applies to DC power supply equipment that meets the following conditions.
a) a DC power port with the definition of 3.1.5;
b) The rated voltage does not exceed 1500VDC.
This standard applies if there is no relevant product or product class electromagnetic compatibility standard.
This standard specifies the test requirements and corresponding measurement/test methods for each port considered.
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only the dated version applies to this document. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 4365-2003 Electrotechnical terminology electromagnetic compatibility
GB/T 6113.101-2016 Specification for equipment and methods of measurement of radio disturbance and immunity - Part 1-1. Radio disturbance and immunity Disturbance measuring device measuring device
GB/T 6113.102-2008 - Radio disturbance and immunity measuring equipment and measuring methods - Part 1-2. Radio disturbance And disturbance immunity measuring equipment auxiliary equipment conduction disturbance
GB/T 6113.104-2016 Radio disturbance and immunity measuring equipment and measuring methods - Part 1-4. Radio disturbances Antenna and test site for radiation disturbance measurement of immunity measuring equipment
GB/T 6113.201-2017 Equipment and methods of measurement of radio disturbance and immunity - Part 2-1. Harassment and immunity test Measurement method
GB/T 6113.203-2016 - Equipment and methods of measurement of radio disturbance and immunity - Part 2-3. Harassment and immunity test Radiation disturbance measurement
GB/T 6113.402 Radio disturbance and immunity measuring equipment and methods of measurement - Part 4-2. Uncertainty, statistics And limit modeling to measure the uncertainty of equipment and facilities
GB/T 17626.2 Electromagnetic compatibility test and measurement technology Electrostatic discharge immunity test
GB/T 17626.3 Electromagnetic compatibility test and measurement technology RF electromagnetic field radiation immunity test
GB/T 17626.4 Electromagnetic compatibility test and measurement technology Electrical fast transient burst immunity test
GB/T 17626.5 Electromagnetic compatibility test and measurement technology Surge (impact) immunity test
GB/T 17626.6 Electromagnetic compatibility test and measurement technology Conducted disturbance immunity of RF field induction
GB/T 17626.8 Electromagnetic compatibility test and measurement technology power frequency magnetic field immunity test
IEC TR61000-1-6 Electromagnetic compatibility - Part 1-6: Overview Guide to measurement uncertainty assessment
CISPR11 Limits and methods of measurement of radio frequency disturbance characteristics for industrial, scientific and medical equipment
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 4365-2003Electrotechnical terminology-Electromagnetic compatibility
- GB/T 6113.101-2016Specification for radio disturbance and immunity measuring apparatus and methods—Part 1-1: Radio disturbance and immunity measuring apparatus—Measuring apparatus
- GB/T 6113.102-2008Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-2: Radio disturbance and immunity measuring apparatus - Coupling devices for conducted disturbance measurements
- GB/T 6113.104-2016Specification for radio disturbance and immunity measuring apparatus and methods—Part 1-4:Radio disturbance and immunity measuring apparatus—Antennas and test sites for radiated disturbance measurements
- GB/T 6113.201-2017Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurements
- GB/T 6113.203-2016Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements
CISPR11
Similar standards
How to Download GB/T 37139-2018
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 17626.2-2018 — Electromagnetic compatibility -- Testing and measurement techniques -- Electrostatic discharge immunity test
GB/T 17626.20-2014 — Electromagnetic compatibility -- Testing and measurement techniques -- Emission and immunity testing in transverse electromagnetic (TEM) waveguide
GB/T 17626.21-2014 — Electromagnetic compatibility -- Testing and measurement techniques -- Reverberation chamber test methods
Secure payment via Stripe
Payments accepted
GB/T 37139-2018
$235.00