GB/T 6113.106-2024Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-6: Radio disturbance and immunity measuring apparatus - EMC antenna calibration (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (146 pages)

Need quotation for your management?

Get a formal quotation for GB/T 6113.106-2024 in 30 minutes.

Issued by

State Administration for Market Regulation, China National Standardization Administration

Level / Type

National · Recommended

Issue date

June 29, 2024

Implementation date

January 1, 2025

Scope

GB/T 6113.106-2024 (Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-6: Radio disturbance and immunity measuring apparatus - EMC antenna calibration) is available as an English-translated PDF.

GB/T 6113.106-2024 — This document gives the antenna calibration procedure and related information when determining the antenna factor (AF) for antennas used for radiated disturbance measurements.

According to IEC Guide 107, CISPR 16-1-6 is the basic electromagnetic compatibility (EMC) standard used by IEC product committees. AF is affected by the surrounding environment and its spatial position relative to the source of the emission.

This document is concerned with antenna calibration, which aims to provide Free space AF in the boresight direction, applicable to the frequency range of 9kHz~18GHz, including antenna types. monopole antenna, loop antenna, Dipole antennas, biconical antennas, log-periodic dipole array (LPDA) antennas, composite antennas, and horn antennas.

This document also serves as a guide for the evaluation of the measurement uncertainty for each calibration method, calibration arrangement and measuring equipment used for calibration.

Found what you need?

Document preview — GB/T 6113.106-2024

National Standard of the People's Republic of China

ICS
33.100
Classification
L 06
Replacing
GB/T 6113.106-2018

Issued by: State Administration for Market Regulation, China National Standardization Administration

Contents

  • Preface
  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms, definitions and abbreviations
  • 3.1 Terms and Definitions
  • 3.2 Abbreviations
  • 4 Basic Concepts
  • 4.1 Overview
  • 4.2 Antenna coefficient principle
  • 4.3 Calibration methods for 30MHz and above
  • 4.4 Measurement uncertainty of antenna calibration results
  • 4.5 Summary of Antenna Factor Calibration Methods
  • 5 Calibration method for the frequency range 9kHz~30MHz
  • 5.1 Monopole Antenna Calibration
  • 5.2 Loop Antenna Calibration
  • 6 Calibration frequency, calibration equipment and function verification of antennas in the frequency range of 30 MHz and above
  • 6.1 Calibration frequency point
  • 6.2 Measurement equipment requirements for antenna calibration
  • 6.3 AUC Function Verification
  • 7 Basic parameters and calculation formulas common to antenna calibration methods in frequency bands above 30 MHz
  • 7.1 Summary of AF Calibration Methods
  • 7.2 Site Insertion Loss Measurement
  • 7.3 Basic formula for calculating AF from SIL and SA measurements
  • 7.4 Calculation formulas for AF and measurement uncertainty when using TAM, SSM and SAM
  • 7.5 Parameters specifying antenna phase centre and position
  • 8 Detailed description of TAM, SAM and SSM calibration methods for frequency bands 30 MHz and above
  • 8.1 Overview
  • 8.2 Considerations for using TAM to calibrate Fa
  • 8.3 Considerations for using SAM to calibrate Fa
  • 8.4 Calibration using SSM on a ground plane site (frequency range 30MHz~1GHz)
  • 9 Calibration procedures for specific antenna types at 30 MHz and above
  • 9.1 Overview
  • 9.2 Biconical and composite antennas in free space environments from 30MHz to 300MHz and from 60MHz to 1000MHz
  • Calibration of a tuned dipole antenna
  • 9.3 Calibration of biconical antennas (30 MHz to 300 MHz) using SAM and vertical polarization on a ground plane site
  • Composite Antenna
  • 9.4 Calibration of LPDA Antennas, Composite Antennas and Horn Antennas in Free Space Environments from.200MHz to 18GHz
  • 9.5 Calibration of Horn Antenna and LPDA Antenna in FAR (Frequency Range 1 GHz~18 GHz)
  • Appendix A (Informative) Basic Principles and Background Information on Antenna Calibration Methods
  • Appendix B (Normative) Calibration of Biconical and Tuned Dipole Antennas on a Ground Plane Using TAM and SAM
  • Appendix C (Informative) Principles of antenna calibration formulas in the 30MHz~1GHz frequency band and related antenna characteristics in uncertainty analysis
  • Appendix D (Informative) Background information and basic principles of antenna calibration above 1 GHz
  • Appendix E (informative) Description of measurement uncertainty assessment
  • Appendix F (Informative) Mismatch uncertainty of a two-port device connected between a transmitting port and a receiving port
  • Appendix G (Informative) Verification Method for Monopole Antenna Calibration and Uncertainty Analysis of ECSM
  • Appendix H (Informative) Helmholtz Coil Method for Calibration of Loop Antennas below 150 kHz
  • Appendix I (Normative) Measurement methods for antenna patterns above 1 GHz and their measurement uncertainty assessment
  • Appendix J (Informative) Monte Carlo Simulation of Measurement Uncertainty of TAM Calibration Loop Antenna --- Source Code Example
  • References

Foreword

This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for standardization work Part 1: Structure and drafting rules for standardization documents" Drafting is required.

GB/T (Z)6113 "Specification for Radio Disturbance and Immunity Measuring Equipment and Measurement Methods" is the basic standard for electromagnetic compatibility.

This document is Part 1-6 of GB/T (Z) 6113.GB/T (Z) 6113 has been published in the following parts.

Part 1: Radio disturbance and immunity measuring equipment

--- Part 1-1.Radio disturbance and immunity measuring equipment - measuring equipment;

--- Part 1-2.Coupling devices for conducting disturbance measurements of radio disturbance and immunity measuring equipment;

--- Part 1-3.Radio disturbance and immunity measuring equipment auxiliary equipment disturbance power;

--- Part 1-4.Antennas and test sites for radiated disturbance measurements of radio disturbance and immunity measuring equipment;

--- Part 1-5.Radio disturbance and immunity measurement equipment 5MHz~18GHz antenna calibration site and reference test site;

--- Part 1-6.Calibration of EMC antennas for radio disturbance and immunity measuring equipment.

Part 2: Methods of measurement of radio disturbances and immunity

--- Part 2-1.Radio disturbance and immunity measurement methods - Conducted disturbance measurement;

--- Part 2-2.Radio disturbance and immunity measurement methods Disturbance power measurement;

--- Part 2-3.Radio disturbance and immunity measurement methods Radiated disturbance measurement;

--- Part 2-4.Radio disturbance and immunity measurement methods Immunity measurement;

--- Part 2-5.Field measurements of disturbance emissions from large equipment.

Part 3: Technical report on radio disturbance and immunity measurements

--- Part 3: Radio disturbance and immunity measurement technical report.

Part 4: Modelling of uncertainty, statistics and limits

--- Part 4-1.Uncertainty, statistics and limit modelling for standardized EMC test uncertainties;

--- Part 4-2.Uncertainty, statistics and limit modelling of uncertainty for measurement equipment and facilities;

--- Part 4-3.Uncertainty, statistics and limit modelling Statistical considerations for determining EMC conformity of batch products;

--- Part 4-4.Uncertainty, statistics and limit modelling Statistics of complaints and limit calculation models for protecting radio services;

--- Part 4-5.Uncertainty, statistics and limit modelling Conditions for use of alternative test methods.

This document replaces GB/T 6113.106-2018 "Radio disturbance and immunity measuring equipment and measurement methods specification Part 1-6.

Compared with GB/T 6113.106-2018, in addition to structural adjustments and edits, this part in addition to the changes in performance, the main technical changes are as follows.

--- Added two abbreviations such as CPM (see 3.2);

--- Changed the content outlined in the loop antenna calibration (see 5.2.1, 5.2.1 of the 2018 edition);

--- Added "three-antenna method" (see 5.2.3);

--- Added "current probe method" (see 5.2.4);

--- Added "Standard Antenna Method" (see 5.2.5);

--- Added "Measurement method of antenna radiation pattern above 1 GHz and its measurement uncertainty assessment" (see Appendix I).

This document is equivalent to CISPR16-1-6.2022 "Radio disturbance and immunity measurement equipment and measurement methods specification 1-6 Part 1: EMC antenna calibration of radio disturbance and immunity measuring equipment.

The following minimal editorial changes were made to this document.

--- As CISPR16-1-6.2022 incorporates the amendment sheet, the formulas, figures and tables are numbered in sequence starting from 5.2.3.

---Corrected the following errors in CISPR16-1-6.2022.

- The uncertainty source in Table 11, "Difference in distance between STA and AUC measurements", corresponds to the standard uncertainty correction.

0.02;

- The contents of paragraphs 2 and 3 in 9.5.1.4 are repeated, and paragraph 2 is deleted;

- Fa(h,p) in B.4.2.2 and B.4.3.2 is corrected to Fa(h,H);

- Z in Figure C.1 is corrected to Z0;

- Figure D.3 shows the measurement data for the case of 1.5m to 2.5m spacing, but the measurement data for 3m is given in the text.

To ensure accuracy, 3m was corrected to 2.5m.

Introduction

To standardize electromagnetic compatibility measurements, consider measurement uncertainties and provide background information related to measurements, as well as to provide electromagnetic compatibility product classification GB/T (Z) 6113 lays the technical foundation for the formulation and revision of the standard. It specifies the radio disturbance and immunity measurement equipment, measurement methods, measurement uncertainty, the first part is the specification of radio disturbance and immunity measurement equipment.

Part 2 is the specification of radio disturbance and immunity measurement methods; Part 3 is the radio disturbance and immunity measurement technical report;

Part 4 is about modelling of uncertainties, statistics and limits.

Part 1 is divided into 6 parts.

--- Part 1-1.Measuring equipment. The purpose is to specify the measuring equipment for measuring radio disturbance and the special equipment for measuring intermittent disturbance.

performance and characteristic requirements of the equipment.

--- Part 1-2.Coupling device for conducting disturbance measurement. The purpose is to specify auxiliary Characteristics and performance requirements of the equipment.

--- Part 1-3.Auxiliary equipment disturbance power. The purpose is to specify the characteristics and calibration of the absorbing clamp used for measuring radio disturbance power.

Standard method requirements.

--- Part 1-4.Antennas and test sites for radiated disturbance measurements. The purpose is to specify antennas and test sites for radiated disturbance measurements characteristics and performance requirements.

--- Part 1-5.5MHz~18GHz antenna calibration site and reference test site. The purpose is to specify the antenna calibration site and refer to the test site requirements.

--- Part 1-6.EMC antenna calibration. The purpose is to specify the calibration procedure and related Require.

Radio disturbance and immunity measuring equipment and Measurement method specifications Part 1-6.Radio disturbance and immunity Measuring equipment EMC antenna calibration

1 Scope

This document gives the antenna calibration procedure and related information when determining the antenna factor (AF) for antennas used for radiated disturbance measurements.

According to IEC Guide 107, CISPR 16-1-6 is the basic electromagnetic compatibility (EMC) standard used by IEC product committees.

AF is affected by the surrounding environment and its spatial position relative to the source of the emission. This document is concerned with antenna calibration, which aims to provide Free space AF in the boresight direction, applicable to the frequency range of 9kHz~18GHz, including antenna types. monopole antenna, loop antenna, Dipole antennas, biconical antennas, log-periodic dipole array (LPDA) antennas, composite antennas, and horn antennas.

This document also serves as a guide for the evaluation of the measurement uncertainty for each calibration method, calibration arrangement and measuring equipment used for calibration.

2 Normative references

The contents of the following documents constitute the essential clauses of this document through normative references in this document.

For referenced documents without a date, only the version corresponding to that date applies to this document; for referenced documents without a date, the latest version (including all amendments) applies to this document.

GB/T 6113.104-2021 Specification for radio disturbance and immunity measuring equipment and methods Part 1-4.Radio disturbance and immunity Interference measurement equipment Radiated disturbance measurement antenna and test site (CISPR16-1-4.2019, IDT) GB/T 6113.105-2018 Specification for radio disturbance and immunity measuring equipment and measurement methods Part 1-5.Radio disturbance and immunity measurement equipment 5MHz~18GHz antenna calibration site and reference test site (CISPR16-1-5.2014, IDT) Note. GB/T 4365-2003 Electrical terminology Electromagnetic compatibility [IEC 60050(161).1990, IDT] CISPR16-1-2 Specification for radio disturbance and immunity measuring equipment and measurement methods Part 1-2.Radio disturbance and immunity Note. GB/T 6113.102-2018 Specification for radio disturbance and immunity measuring equipment and methods Part 1-2.Radio disturbance and immunity measuring equipment Coupling device for measuring conducted disturbances of measuring equipment (CISPR16-1-2.2014, IDT) ISO/IEC Guide 98-3.2008 Uncertainty in measurement Part 3: Guide to the expression of uncertainty in measurement (GUM.1995)

1995)]

Note. GB/T 27418-2017 Evaluation and expression of measurement uncertainty (ISO/IEC Guide 98-3..2008, MOD)

3 Terms, definitions and abbreviations

3.1 Terms and Definitions

For the purposes of this document, the terms and definitions defined in IEC 60050-161 and the following apply.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 146 pages — is available in the English PDF.

Referenced standards

How to Download GB/T 6113.106-2024

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
146 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 6113.106-2024

$2,450.00