GB/T 31983.11-2015Narrow band power line communication over low-voltage mains—Part 11: 3 kHz to 500 kHz frequency bands and classifications, limits of output level and electromagnetic disturbances (English PDF)

低压窄带电力线通信 第11部分:3 kHz~500 kHz频带划分、输出电平和电磁骚扰限值

Preview PDF

This is a limited preview

Buy now to download the full PDF (30 pages)

Need quotation for your management?

Get a formal quotation for GB/T 31983.11-2015 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

September 11, 2015

Implementation date

April 1, 2016

Scope

GB/T 31983.11-2015 is the English-translated version of 低压窄带电力线通信 第11部分:3 kHz~500 kHz频带划分、输出电平和电磁骚扰限值.

GB/T 31983.11-2015 is the Chinese standard "Narrow band power line communication over low-voltage mains - Part 11: 3 kHz to 500 kHz frequency bands and classifications, limits of output level and electromagnetic disturbances".

Its scope clause reads: This Part of GB/T 31983 specifies the frequency band classification for different applications, the output level limit in the available frequency band, the conducted and radiated disturbance limit; and gives the measurement method.

This Part does not specify signal modulation methods, coding methods or functional characteristics, nor does it include environmental requirements and tests.

This Part is applicable to electrical equipment that uses signals in the frequency range of 3kHz ~ 500kHz for information transmission on low-voltage power distribution systems or on user-side power devices.

Its clauses include terms and definitions; classification and application of frequency band; output level; limits of electromagnetic disturbance; test conditions; safety warning.

It was issued by the General Administration of Quality Supervision, Inspection and Quarantine on SEPTEMBER 11, 2015 and took effect on APRIL 01, 2016.

Found what you need?

Document preview — GB/T 31983.11-2015

National Standard of the People's Republic of China

ICS
17.220.20
Classification
N 22

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword3
  • 1 Scope5
  • 2 Normative References5
  • 3 Terms and Definitions6
  • 4 Classification and Application of Frequency Band7
  • 4.1 Overview7
  • 4.2 3kHz~95kHz frequency band7
  • 4.3 95kHz~150kHz frequency band7
  • 4.4 150kHz~500kHz frequency band8
  • 5 Output Level8
  • 5.1 General requirements8
  • 5.2 Output signal measurement10
  • 5.3 Maximum output level11
  • 5.4 Output level identification21
  • 6 Limits of Electromagnetic Disturbance21
  • 6.1 Overview21
  • 6.2 Conducted disturbance limit22
  • 6.3 Limit of radiated disturbance field strength23
  • 6.4 Disturbance power limit23
  • 6.5 Other requirements to limit disturbance24
  • 7 Test Conditions24
  • 8 Safety Warning25
  • Appendix A (Normative) Attenuation Characteristics of Measuring Instruments above 150kHz27
  • Appendix B (Normative) Measurement Method (3kHz~30MHz) - Artificial Mains Network29
  • Appendix C (Informative) Design of Artificial Mains Network Used to Indicate the Signal Transmission Performance30

1 Scope

This Part of GB/T 31983 specifies the frequency band classification for different applications, the output level limit in the available frequency band, the conducted and radiated disturbance limit; and gives the measurement method.

This Part does not specify signal modulation methods, coding methods or functional characteristics, nor does it include environmental requirements and tests.

This Part is applicable to electrical equipment that uses signals in the frequency range of 3kHz ~ 500kHz for information transmission on low-voltage power distribution systems or on user-side power devices.

2 Normative References

The following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document; for the undated documents, only the latest version (including all the amendments) are applicable to this document.

GB/T 4365 Electrotechnical Terminology - Electromagnetic Compatibility

GB/T 6113.101-2008 Specification for Radio Disturbance and Immunity Measuring Apparatus and Methods - Part 1-1: Radio Disturbance and Immunity Measuring Apparatus - Measuring Apparatus

GB/T 6113.102-2008 Specification for Radio Disturbance and Immunity Measuring Apparatus and Methods - Part 1-2: Radio Disturbance and Immunity Measuring Apparatus - Ancillary Equipment - Conducted Disturbance

GB/T 6113.104-2008 Specification for Radio Disturbance and Immunity Measuring Apparatus and Methods - Part 1-4: Radio Disturbance and Immunity Measuring Permanently installed AC power network system consisting of wires or cables, but does not include flexible cables that users can connect or disconnect.

3 Terms and Definitions

3.9 Sensitive equipment

A device that is subject to interference may cause adverse effects and cause injury.

4 Classification and Application of Frequency Band

4.2 3kHz~95kHz frequency band This frequency band is suitable for monitoring and controlling electrical equipment on low-voltage power distribution networks. The main equipment includes various smart metering instruments and monitoring and control terminals or devices.

NOTE: A typical application example of this frequency band is the collection of electricity consumption information of the Advanced Metering Infrastructure (AMI).

4.3 95kHz~150kHz frequency band This frequency band is suitable for:

a) Monitor and control low-voltage electrical equipment in residential, commercial or industrial premises;

b) Monitor and control electrical equipment installed or connected to the low-voltage power distribution network outside the site.

NOTE 1: Typical application examples of a) may be intelligent buildings, intelligent homes and home energy management.

NOTE 2: Typical application examples of b) may be street lamp control, energy metering, and electric vehicle charging and discharging.

The equipment used in this frequency band is divided into Class-122 and Class-134 equipment. According to the specified measurement method, the maximum output level of Class-122 equipment is 122dB(µV); and the maximum output level of Class- In order to prevent damage to the equipment under test or test instrument, it shall be ensured that the power supply voltage applied to the equipment under test meets the power supply voltage range requirements specified by the equipment manufacturer.

Generally, differential mode signaling shall be used. The common-mode signaling on the fixed mains network can only be used in commercial or industrial premises and work under the conditions described in Clause 7.

If the common mode signal sent from the fixed power outlet to the fixed mains network is lower than the out-of-band disturbance limit specified in Clause 6, the common-mode signaling is allowed on a flexible cable.

4.1 Overview

In order to ensure the coexistence between different applications and prevent mutual interference, this Part establishes various applications by classifying the frequency bands.

NOTE: If it causes interference to radio communication services, additional provisions may be adopted.

5 Output Level

5.1 General requirements

5.1.2 Single-phase equipment measurement circuit

To measure the output level in the frequency range of 3kHz~9kHz, an artificial mains network (AMN, Artificial Mains Network) that meets the impedance characteristics described in Figure 2 shall be used.

To measure the output level in the frequency range of 9kHz~150kHz, a single-phase artificial mains network complying with 4.2 of GB/T 6113.102-2008 shall be used.

To measure the output level in the frequency range of 150kHz~500kHz, a single-phase artificial mains network complying with 4.3 of GB/T 6113.102-2008 shall be used.

NOTE: If the impedance (modulus and phase angle) of the single-phase artificial mains network complying with 4.2 of GB/T 6113.102-2008 in the frequency range of 150kHz ~ 500kHz meets the impedance requirements of 4.3 in GB/T 6113.102-2008; then the former single-phase artificial mains network is also suitable for the measurement of the frequency range of 150kHz~500kHz. Pay attention to the NOTE of 4.2 in GB/T 6113.102-2008.

5.1.3 Three-phase equipment measurement circuit

To measure the output level in the frequency range of 3kHz~9kHz, a three-phase artificial mains network that meets the impedance characteristics described in Figure 2 shall be used.

To measure the output level in the frequency range of 9kHz~150kHz, a three-phase artificial mains network conforming to 4.2 of GB/T 6113.102-2008 shall be used.

To measure the output level in the frequency range of 150kHz~500kHz, a three-phase artificial mains network conforming to 4.3 of GB/T 6113.102-2008 shall be used.

NOTE 1: The NOTE of 5.1.2 also apply.

If the user manual of the equipment clearly indicates that the three-phase equipment can connect all phase terminals to the same phase line as a single-phase equipment, the difference in load conditions between three-phase and single-phase may cause

a) The signal bandwidth < 5kHz. The output level measured on any phase line shall not exceed 128dB(µV) at 9kHz, and shall not exceed 114dB(µV) at 95kHz. It decreases linearly with the logarithm of the frequency between 9kHz and 95kHz.

b) The signal bandwidth is >=5kHz. The output level measured on any phase line shall not exceed 128dB(µV). In addition, when using a 200Hz bandwidth peak detector to measure, any part of the signal spectrum shall not exceed 114dB(µV).

NOTE: NOTE 3 of 5.1.3 also applies.

Measurement shall be made according to 5.2.2; the equipment connection is shown in Figure 7.

The output level shall be limited according to the type of used equipment as follows:

NOTE: NOTE 3 of 5.1.3 also applies.

Measurement shall be made according to 5.2.2; the equipment connection is shown in Figure 7.

NOTE: NOTE 3 of 5.1.3 also applies.

5.3 Maximum output level

5.3.2.3 95kHz~150kHz frequency band The artificial mains network conforming to the impedance characteristics of Figure 1a) of 4.2 in GB/T 6113.102-2008 shall be used for measurement, see 5.3.1.2 for the description of the artificial mains network.

a) Class-122 equipment. The output level measured on any phase line shall not exceed 116dB(µV).

b) Class-134 equipment. The output level measured on any phase line shall not exceed 128dB(µV).

5.3.2.4 150kHz~500kHz frequency band The artificial mains network conforming to the impedance characteristics of Figure 1b) of 4.3 in GB/T 6113.102-2008 shall be used for measurement, see 5.3.1.4 for the description of the artificial power supply network.

The output level measured on any phase line shall not exceed 128dB(µV). In addition, when using a 200Hz bandwidth peak detector to measure, any part of the signal spectrum shall not exceed 114dB(µV).

5.3.3 Three-phase equipment transmits simultaneously between phase lines

(no neutral line)

The output level shall be limited by the following signal bandwidth:

a) The signal bandwidth < 5kHz. The output level measured on any phase line shall not exceed 134dB(µV) at 9kHz, and shall not exceed 120dB(µV) at 95kHz; It decreases linearly with the logarithm of the frequency between 9kHz and 95kHz.

b) The signal bandwidth is >=5kHz. The output level measured on any phase line shall not exceed 134dB(µV). In addition, when using a 200Hz bandwidth peak detector to measure, any part of the signal spectrum shall not exceed 120dB(µV).

5.3.3.3 95kHz~150kHz frequency band The artificial mains network conforming to the impedance characteristics of Figure 1a) of 4.2 in GB/T 6113.102-2008 shall be used for measurement, see 5.3.1.2 for the description of the artificial power supply network.

Measurement shall be made according to 5.2.2; the equipment connection is shown in Figure 8.

The output level shall be limited according to the type of used equipment as follows:

a) Class-122 equipment. The output level measured on any phase line shall not exceed 122dB(µV).

b) Class-134 equipment. The output level measured on any phase line shall not exceed 134dB(µV).

5.3.3.4 150kHz~500kHz frequency band The artificial mains network conforming to the impedance characteristics of Figure 1b) of 4.3 in GB/T 6113.102-2008 shall be used for measurement, see 5.3.1.4 for the description of the artificial mains network.

Measurement shall be made according to 5.2.2; the equipment connection is shown in Figure 8.

The output level measured on any phase line shall not exceed 134dB(µV). In addition, when using a 200Hz bandwidth peak detector to measure, any part of the signal spectrum shall not exceed 120dB(µV).

5.3.4 Three-phase equipment transmits on single-phase

The measurement shall be made on the phase line or the neutral line. The limits specified in 5.3.1 for the relevant frequency range is applicable to this measurement.

5.3.5 Summary of maximum output level

Appendix B (Normative) Measurement Method (3kHz~30MHz) - Artificial Mains Network

B.1 Overview

In order to measure the terminal voltage generated by the signal transmission equipment, a V-shaped artificial mains network is required to provide a specified impedance to the terminal of the device under test within the radio frequency range; and an additional inductor is required to isolate the test circuit from the useless radio frequency signal on the power supply.

This Appendix gives the relevant information of the artificial mains network, all other requirements are given in GB/T 6113.102-2008.

B.2 Impedance

B.2.1 3kHz~9kHz frequency range For the frequency range of 3kHz~9kHz, the correction network of 4.2 and Figure 4 in GB/T 6113.102-2008 shall be used, as shown in Figure 3.

The impedance of the 0.47µF capacitor C3 (see Figure 3) is not negligible. Unless otherwise specified, the reading of the measuring device needs to be corrected due to the voltage dividing caused by this impedance.

B.2.2 9kHz~30MHz frequency range The impedance of the V-shaped artificial mains network shall satisfy the 50 ohm/50µH+5 ohm and 50 ohm/50µH specified in 4.2 Figure 1a) and 4.3 Figure 1b) of GB/T 6113.102-2008.

NOTE 1: Pay attention to the NOTE of 4.2 in GB/T 6113.102-2008.

NOTE 2: Pay attention to the consideration of correction factors in the detailed description of Table A.1 in Appendix A.2 of GB/T 6113.102-2008. […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 30 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 31983.11-2015

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
30 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 31983.11-2015

$325.00