Scope
GB/T 5590-2024 is the English-translated version of 矿用防爆低压电磁起动器.
GB/T 5590-2024 is the Chinese standard "Low voltage explosion protection electromagnetic starter for mining".
Its scope clause reads: This document specifies the classification and naming, characteristics, normal working conditions and technical requirements of explosion-proof low-voltage electromagnetic starters for mining, and describes the relevant It specifies the corresponding test methods, inspection rules, and requirements for marking, packaging, transportation and storage.
This document is applicable to the control of three-phase squirrel cage asynchronous power in coal mines with rated frequency of 50 Hz and voltage of 1 140 V or less.
The motor can be started and stopped locally or remotely, reversed and double-speed, and the mining explosion-proof low-voltage electromagnetic starter can protect the motor and related circuits at the same time.
Design, manufacture and inspection of starters (hereinafter referred to as “starters”). The provisions of this document concerning overload protection (see 7.3.10 and 8.2.12) do not apply to embedded overheating protection devices installed inside the motor. device.
Found what you need?
Document preview — GB/T 5590-2024
National Standard of the People's Republic of China
- ICS
- 29.260.20
- Classification
- K 35
- Replacing
- GB/T 5590-2008
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- 1 Scope1
- 2 Normative references1
- 3 Terms, definitions and symbols2
- 3.2 Symbols2
- 4 Classification and naming2
- 4.1 Classification2
- 4.2 Naming3
- 5 Features3
- 5.2 Category of use3
- 5.3 Control Circuit4
- 5.4 Auxiliary circuit4
- 5.5 Protection function4
- 6 Normal working conditions4
- 7 Technical Requirements5
- 7.2 Explosion-proof safety requirements5
- 8 Test methods17
- 9 Inspection Rules18
- 9.1 Inspection categories18
- 9.2 Type inspection18
- References23
1 Scope
This document specifies the classification and naming, characteristics, normal working conditions and technical requirements of explosion-proof low-voltage electromagnetic starters for mining, and describes the relevant
It specifies the corresponding test methods, inspection rules, and requirements for marking, packaging, transportation and storage.
This document is applicable to the control of three-phase squirrel cage asynchronous power in coal mines with rated frequency of 50 Hz and voltage of 1 140 V or less.
The motor can be started and stopped locally or remotely, reversed and double-speed, and the mining explosion-proof low-voltage electromagnetic starter can protect the motor and related circuits at the same time.
Design, manufacture and inspection of starters (hereinafter referred to as “starters”).
The provisions of this document concerning overload protection (see 7.3.10 and 8.2.12) do not apply to embedded overheating protection devices installed inside the motor.
device.
2 Normative references
The contents of the following documents constitute the essential clauses of this document through normative references in this document.
For referenced documents without a date, only the version corresponding to that date applies to this document; for referenced documents without a date, the latest version (including all amendments) applies.
in this document.
GB/T 191 Pictorial markings for packaging, storage and transportation
GB/T 762 standard current level
GB/T 2423.4 Environmental testing for electric and electronic products Part 2.Test methods Test Db. Cyclic damp heat (12 h + 12 h cycle)
GB/T 2423.5 Environmental testing Part 2.Test method Test Ea and guidance. Impact
GB/T 2423.10 Environmental testing Part 2.Test methods Test Fc. Vibration (sinusoidal)
GB/T 2900.18 Electrical terminology Low voltage electrical appliances
GB/T 2900.35 Electrical terminology Explosive atmospheres
GB/T 3836.1-2021 Explosive atmospheres Part 1.Equipment General requirements
GB/T 3836.2-2021 Explosive atmospheres Part 2.Equipment protected by flameproof enclosure "d"
GB/T 3836.3-2021 Explosive atmospheres Part 3.Equipment protected by increased safety "e"
GB/T 3836.4-2021 Explosive atmospheres Part 4.Equipment protected by intrinsic safety type "i"
GB/T 4205 Basic and safety rules for human-machine interface signs and symbols Operating rules
GB/T 4208-2017 Enclosure protection degree (IP code)
GB/T 10111 Generation of random numbers and their application in product quality sampling inspection
GB/T 14048.1-2023 Low-voltage switchgear and controlgear Part 1.General
GB/T 14048.4-2020 Low-voltage switchgear and controlgear Part 4﹘1.Contactors and motor starters Electromechanical contactors
Contactors and motor starters (including motor protectors)
GB/T 14048.5 Low-voltage switchgear and controlgear Part 5﹘1.Control circuit devices and switching elements Electromechanical control circuits
Road Electric
GB/Z 3836.37 | GB/T 3836.4 | GB/T 3836.8 | GB 3836.15 | […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 28 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 191Graphical symbols marking for handling and storage of packages
- GB/T 762Standard current ratings
- GB/T 2423.4Environmental testing for electric and electronic products - Part 2: Test method - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
- GB/T 2423.5Environmental testing - Part 2: Test methods - Test Ea and guidance: Shock
- GB/T 2423.10Environmental testing - Part 2: Test methods - Test Fc: Vibration (sinusoidal)
- GB/T 2900.18Electrotechnical terminology - Low voltage apparatus
Editions of GB/T 5590
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB/T 5590-2024 | Low voltage explosion protection electromagnetic starter for mining | current edition | Current |
| GB/T 5590-2008 | Low voltage explosion protection electromagnetic starter for mining | previous edition | In force |
| GB 5590-1985 | Mining type flameproof electric magnetic starters | previous edition | Obsolete |
This page sells the current edition, GB/T 5590-2024. Earlier editions are listed for reference only.
How to Download GB/T 5590-2024
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10111-2008 — Generation of random numbers and procedures applied to sampling inspection for product quality
GB/T 14048.1-2023 — Low-voltage switchgear and controlgear-Part 1: General rules
GB/T 14048.4-2020 — Low-voltage switchgear and controlgear - Part 4-1: Contactors and motor-starters - Electromechanical contactors and motor-starters(Including motor protector)
Secure payment via Stripe
Payments accepted
GB/T 5590-2024
$495.00