Valid

GB/T 39830-2021Code for seismic design of steel static storage systems (English PDF)

立体仓库钢结构货架抗震设计规范

Preview PDF

This is a limited preview

Buy now to download the full PDF (20 pages)

Need quotation for your management?

Get a formal quotation for GB/T 39830-2021 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

March 9, 2021

Implementation date

October 1, 2021

Scope

GB/T 39830-2021 is the English-translated version of 立体仓库钢结构货架抗震设计规范.

GB/T 39830-2021 is the Chinese code for the seismic design of steel static storage systems, the pallet racking of a warehouse. It gives the general provisions, the seismic design process, the seismic action and the calculation of the structure under it, the analysis methods and the structural requirements.

It applies to the design of steel storage racking against earthquake. Racking makers, warehouse owners and design institutes use it. Issued on 9 March 2021, it has applied since 1 October 2021.

Found what you need?

Document preview — GB/T 39830-2021

National Standard of the People's Republic of China

ICS
53.080
Classification
J 83

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword3
  • 1 Scope4
  • 2 Normative references4
  • 3 General provisions4
  • 4 Seismic design process5
  • 5 Seismic action and structural seismic calculation8
  • 6 Analysis methods11
  • 7 Construction requirements16
  • Bibliography20

Foreword

This Standard was drafted in accordance with the rules given in GB/T 1.1-2009.

1 Scope

This Standard specifies the design code for steel static storage systems under seismic action. The contents include general provisions, seismic design process, seismic action and structural seismic calculation, analysis methods and structural requirements.

This Standard applies to steel structure racks (hereinafter referred to as steel racks), not to racks made of other materials.

2 Normative references

The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.

GB 18306 Seismic ground motion parameters zonation map of China

GB/T 28576-2012 Calculation of industrial rack design

GB 50011-2010 Code for seismic design of buildings (2016 edition)

GB 50223 Standard for classification of seismic protection of building constructions

3 General provisions

3.1 The seismic fortification intensity shall be determined according to the basic seismic intensity (looked up in GB 18306) of the area where the steel rack is used.

3.2 The steel racks that need to withstand seismic action in areas with the seismic fortification intensity of 6 degrees and above shall be designed for earthquake resistance.

3.4 This Standard is designed according to the internal force and deformation analysis under the action of frequent earthquakes. The structure and components can be considered according to the elastic working state.

4 Seismic design process

4.1 Basic parameters of seismic fortification

4.1.1 The site is divided into five categories. I0, I1, II, III, and IV, which shall be determined through site survey.

4.1.4 According to the amax calculated by 4.1.2, look up Table 3 to determine the maximum value of the horizontal seismic influence coefficient alphamax.

4.1.5 The damping ratio eta of steel rack structures should refer to the damping ratio of steel structures in 8.2.2 of GB 50011-2010. When the height is not more than 50 m, it can be taken as 0.04; when the height is greater than 50 m, it can be taken as 0.03.

4.1.6 The natural vibration period T of steel racks can be calculated according to theory or determined according to empirical formula (2).

4.1.7 For the calculation of the seismic influence coefficient alpha, it shall be determined according to 5.1.5 in GB 50011-2010.

4.3 Structural seismic calculation

The structural seismic calculation shall be carried out according to the analysis model of 4.2 and the seismic analysis method specified in 6.1. The horizontal seismic action shall be determined by 5.2. For the structure shown in Figure 1, the vertical seismic action shall be calculated.

4.4 Determination of load and load combination

The various permanent loads and variable loads for seismic design shall be determined according to 5.5. The load combination shall be determined according to 5.6.1. Data such as the internal force of members, the reaction force of upright foot and the node displacement shall be calculated according to the load combination.

5 Seismic action and structural seismic calculation

5.1 Description of seismic action

The seismic action is generally described by response spectrum, which shall follow the design response spectrum of GB 50011-2010, and be represented in the form of seismic influence coefficient curve alpha, see 5.1.5 in GB 50011-2010.

5.5 Loads considered simultaneously with seismic action

5.5.1 Permanent load PDL

Permanent loads of steel racks include.

5.5.3 Wind load PWL

For static storage system such as rack-clad building, the wind load shall be considered, and the combined action shall be considered according to the relevant provisions of GB 50011-2010.

5.6 Design and check of bearing capacity limit state

5.6.1 Load combination

When calculating the horizontal seismic action, take the most unfavorable load combination, and determine the design value Pmax in the following two cases.

5.6.2 Gravity second order analysis

The seismic analysis shall consider the influence of the gravity second order, and refer to the relevant requirements in 5.1.6 of GB 50017-2017.

5.6.3 Sectional seismic check

Under the load combination specified in 5.6.1, the design value of internal force combination of structural member Pmax shall meet the following requirements.

5.6.4 Steel rack spacing

The steel racks shall have enough spacing to prevent collisions in earthquakes. The spacing shall not be less than 3 times the maximum deformation of the racks under the action of frequent earthquakes, including the following two typical cases.

5.6.5 Seismic deformation check

The seismic analysis results of steel racks shall meet the requirements of inter-level displacement. The inter-level displacement can be calculated according to formula (8).

6 Analysis methods

6.1 Selection of seismic analysis methods

6.1.1 Bottom shear method

The bottom shear method is generally used for steel racks with a height of no more than 40 m, of which the structural rule is mainly shear deformation, and the distribution of mass and stiffness along the height is relatively uniform.

6.2 Structural modeling

6.2.1 Load distribution

The seismic analysis shall consider the most unfavorable load distribution. At least the following load distribution forms shall be considered.

6.2.2 Position of the center of gravity of unit cargo

6.2.2.1 The unit cargo can be regarded as a substructure of the steel rack structure. If the unit cargo is larger in size, it shall consider the influence of the position of its center of gravity on the steel rack structure.

6.2.2.2 In the Z direction, it shall consider the height of center of gravity of the load unit relative to the beam (may be called vertical eccentricity).

6.2.2.3 The vertical eccentricity of unit cargo in the X direction may not be considered, except for the case where the rack has only one row.

6.2.3 Specific modeling requirements

6.2.3.1 In the X direction, the restraint form of beam-upright joints and upright foot joints shall be handled according to 5.2.5 in GB/T 28576-2012, and the stiffness value of beam-upright joints and upright foot should be obtained through the test according to 7.5 and 7.6 of GB/T 39681-2020.

6.2.3.3 When the steel rack adopts flexible cross bracing, the cross bracing shall be set as a tension-only member in the analysis model.

6.2.3.4 It shall add plane connectors between the back bracing and the rack to improve the lateral resistance of the structure, see Figure 8 Structure 1.

7 Construction requirements

7.1 Horizontal lateral force resistance structure

7.1.1 In the Z direction, the main lateral force resistance structure is the upright frame.

The upright frame structure should use the K-shaped, D-shaped, Z-shaped support and X-shaped support without cross bar, as shown in Figure 6.

7.1.2 In the X direction, there are three types of lateral force resistance structures.

7.2 Other constructions

7.2.1 The upright is generally fixed on the ground through the upright foot connector.

The upright and the upright foot connector can be fixed by welding or by bolts. When using bolts to fix, if it is fixed through long holes (the direction of the force is the direction of the long holes) or oversized holes, it shall have anti-slip design, such as high-strength friction bolt connection, to avoid displacement of the upright foot.

7.2.2 When members such as flat steel, round steel and cable are used as bracings, it shall be ensured that these bracings are always in a tensioned state under gravity.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 20 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 39830-2021

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
20 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 39830-2021

$285.00