Valid

GB/T 38802-2020Management specification for water-saving of swimming places (English PDF)

游泳场所节水管理规范

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 38802-2020 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

June 2, 2020

Implementation date

October 1, 2020

Scope

GB/T 38802-2020 is the English-translated version of 游泳场所节水管理规范.

GB/T 38802-2020 is the Chinese standard "Management specification for water-saving of swimming places". Its scope clause reads: This standard specifies the relevant terms and definitions, basic requirements, equipment and facilities requirements and quota management requirements for water saving in swimming places.

This standard applies to various swimming places such as artificial swimming places and water amusement facilities. Its clauses include terms and definitions; basic requirements; equipment and facilities requirements; quota management requirements.

Found what you need?

Document preview — GB/T 38802-2020

National Standard of the People's Republic of China

ICS
03.100.50
Classification
P 01

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Basic requirements
  • 5 Equipment and facilities requirements
  • 6 Quota management requirements

1 Scope

This standard specifies the relevant terms and definitions, basic requirements, equipment and facilities requirements and quota management requirements for water saving in swimming places.

This standard applies to various swimming places such as artificial swimming places and water amusement facilities.

2 Normative references

The following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this article

Pieces. For undated references, the latest version (including all amendments) applies to this document.

GB 5749 Sanitary Standard for Drinking Water

GB/T 12452 General Rules of Water Balance Test for Enterprises

GB 24789 General Rules for the Provision and Management of Water Measuring Instruments for Water Use Units

GB 25501 faucet water efficiency limit value and its water efficiency grade

GB 25502 Water efficiency limit value and water efficiency grade of toilet

GB 28377 Urinal water efficiency limit value and water efficiency grade

GB 28378 Water efficiency limit value and water efficiency grade of shower

GB 30717 Water efficiency limit value and water efficiency grade of squatting toilet

GB/T 31436 Water-saving sanitary ware

CJJ122 Technical Specification for Swimming Pool Water Supply and Drainage Engineering

CJ/T 164 Water-saving domestic water appliance

CJ/T 244 Swimming Pool Water Quality Standard

3 Terms and definitions

CJJ122 and the following terms and definitions apply to this document.

3.1 Swimmingplace

Indoor and outdoor water surfaces (domains) and facilities and equipment that can satisfy people for swimming, fitness, training, competitions, entertainment and other activities.

3.2 Watersupplementrate

The proportion of the total amount of water added to the swimming pool in a unit time to the original pool water.

3.3 Watercirculationandfiltrationsystem

The used swimming pool water is pumped out of the pool according to the specified flow and flow rate, and the pool water is clarified by filtration and purification and disinfected.

After treatment, it reaches the relevant water quality standards and then returns to the reuse system in the swimming pool.

4 Basic requirements

4.1

Water conservation management system should be established and perfected, water conservation management post responsibility system should be implemented, and management personnel should be assigned.

4.2

The sanitation of swimming places should meet the requirements of relevant national regulations.

4.3

The water quality of the swimming pool’s initial water filling, water change and replenishment during operation shall meet the requirements of GB 5749, and the water quality of the pool shall meet the requirements of GB 5749.

CJ/T 244 requirements.

4.4

Water measuring instruments shall be equipped in accordance with the requirements of GB 24789 and normal operation shall be ensured. There should be a complete water supply and drainage network diagram and water meter

The measuring device is equipped with network charts.

4.5

The annual water use plan should be strictly implemented, and the original water use records and statistical accounts should be fully standardized.

4.6

The inspection and maintenance of water facilities should be strengthened to prevent running and dripping. The level should be carried out at least once in 5 years in accordance with the requirements of GB/T 12452.

Balance test.

4.7

Water-saving signs should be posted in conspicuous positions.

4.8

The staff shall be trained on water conservation regularly.

5 Equipment and facilities requirements

5.1

The swimming pool water purification should adopt the circulating water purification treatment mode according to local conditions, and encourage the use of circulating purification systems with advanced water-saving technologies.

5.2

On the basis of ensuring the humidity of swimming places, the recycling of condensed water is encouraged. When the swimming pool is not open, it should be used to prevent the pool water surface

Evaporation and insulation measures.

5.3

The swimming pool should use water-saving sewage suction equipment to clean up the sediment, and the discharged sewage should be recycled.

5.4

Water-saving flushing equipment should be used when cleaning the pool bank.

5.5

Swimming pool overflow water should be recycled.

5.6

The backwash drainage of the filter equipment should be recycled and reused.

5.7

Central air-conditioning cooling water should be recycled, and the recycling rate should not be less than 98%.

5.8

Water-using appliances should comply with GB 25501, GB 25502, GB 28377, GB 30717, GB 28378, GB/T 31436, CJ/T 164, etc.

Water saving requirements.

5.9

The shower should adopt an intelligent control switch.

6 Quota management requirements

6.1 Water quota

The water quota for swimming places should meet the requirements of Table 1.

6.2 Calculation method

6.2.1 Daily water replenishment rate of swimming pool

The percentage of daily water replenishment in the swimming pool to the volume of the swimming pool is calculated according to formula (1).

6.2.2 Single shower water consumption per person

In unit time, the water consumption of a single shower, calculated according to the number of showers in the swimming place and the number of sessions, is calculated according to formula (2).

6.2.3 Water consumption per audience per audience

Within the bit time, (3) calculate.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 38802-2020

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 38802-2020

$70.00