GB/T 38252-2019Test method of fire-resistant integrity for building windows and doors (English PDF)

建筑门窗耐火完整性试验方法

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 38252-2019 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

December 10, 2019

Implementation date

November 1, 2020

Scope

GB/T 38252-2019 is the English-translated version of 建筑门窗耐火完整性试验方法.

GB/T 38252-2019 is the Chinese standard "Test method of fire-resistant integrity for building windows and doors".

Its scope clause reads: This standard specifies the terms and definitions, classification, test devices, test pieces and installation, test conditions, test procedures, test results and judgment, and test reports of test method of fire-resistant integrity for building windows and doors.

This standard is applicable to building windows and doors with fire-resistant integrity requirements, but not to fireproof windows and doors. Its clauses include terms and definitions; classification; test device.

Found what you need?

Document preview — GB/T 38252-2019

National Standard of the People's Republic of China

ICS
91.060.50
Classification
P 32

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword i
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Classification
  • 5 Test device
  • 6 Test pieces and installation
  • 7 Test conditions
  • 8 Test procedure
  • 9 Test results and judgment
  • 10 Test report
  • Annex A (Informative) Standard test piece specification of fire-resistant integrity test for building windows and doors

1 Scope

This standard specifies the terms and definitions, classification, test devices, test pieces and installation, test conditions, test procedures, test results and judgment, and test reports of test method of fire-resistant integrity for building windows and doors.

This standard is applicable to building windows and doors with fire-resistant integrity requirements, but not to fireproof windows and doors.

2 Normative references

The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced documents (including any amendment) applies.

GB/T 5823 Terminology for building windows and doors

GB/T 5907.1 Fire protection vocabulary - Part 1: General Terms

GB/T 9978.1-2008 Fire-resistance tests - Elements of building construction - Part 1: General requirements

GB/T 26784-2011 Fire resistance test for elements of building construction - Alternative and additional procedures

GB/T 31433-2015 General specification for building curtain walls, windows and doors

3 Terms and definitions

For the purposes of this standard, the following terms and definitions given in GB/T 5823 and GB/T 5907.1 and the following apply.

3.1

fire-resistant integrity of windows and doors ability of building windows and doors, with a certain side of exposed to fire, to prevent the penetration of flame and hot gas or to prevent flame from appearing on the unexposed side within a certain period of time under the test conditions specified in this standard

3.2 outside fire curve

standard curve for simulating time-temperature relationship of fire in outdoor space

3.3 inside fire curve

standard curve for simulating time-temperature relationship of fire in indoor space

3.4 fire-resistant time

fire resistance limit of test piece to maintain integrity in the fire integrity test of windows and doors

4 Classification

4.1 Classification index

The fire-resistant integrity of building windows and doors is expressed by E, and the fire-resistant time is taken as the classification index; the fire-resistant time is expressed by t in min.

4.2 Classification requirements

The fire-resistant integrity of building windows and doors shall be classified by indoor and outdoor exposed side, with indoor side indicated by "i" and outdoor side indicated by "o". See Table 1 for classification and index values.

Table 1 Classification table of fire-resistant integrity

Classification Code

Exposed side Indoor side E30(i) E60(i)

Outdoor side E30(o) E60(o)

Fire-resistant time (t)/min 30 <= t < 60 t >= 60

5 Test device

5.1 Test furnace

The test furnace shall meet the requirements of 5.2 of GB/T 9978.1-2008 and the following:

a) The clearance dimension of the installation opening of the test piece shall not be less than 3000 mm × 3000 mm; when the dimension of the test piece is smaller than the installation opening, the test piece shall be installed in the support frame and firmly installed in the opening;

b) It shall be able to set and control the temperature in the furnace to meet the requirements of 7.1;

c) It shall be able to control and monitor the pressure of hot flue gas in the furnace to meet the requirements of 7.2.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 38252-2019

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 38252-2019

$185.00