Valid

GB/T 35031.1-2018Customer energy management system—Part 1: Guideline (English PDF)

用户端能源管理系统 第1部分:导则

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 35031.1-2018 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

May 14, 2018

Implementation date

December 1, 2018

Scope

GB/T 35031.1-2018 is the English-translated version of 用户端能源管理系统 第1部分:导则.

GB/T 35031.1-2018 is the guideline part of the Chinese series on customer energy management systems, the systems a site uses to manage the electricity, water, gas, heat and cooling it consumes.

It describes the concept of the customer energy management system and its relationship with energy suppliers and energy service providers, sets out the interoperability architecture and gives the general security protection requirements.

Electrical energy is used as the main example, but the guidance also applies to the other energy forms. Terms such as representational state transfer (REST) and actor are defined, drawing on the smart grid customer interface documents GB/Z 32500 and GB/Z 32501.

It guides the design, development, construction, operation, maintenance and management of these systems. It was issued on 14 May 2018 and has applied since 1 December 2018.

Found what you need?

Document preview — GB/T 35031.1-2018

National Standard of the People's Republic of China

ICS
29.020
Classification
K 00

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions, abbreviations
  • 4 User Energy Management System Concept
  • 5 Client Energy Management System Interoperability Architecture
  • 6 System Security Protection General Requirements

Foreword

GB/T 35031 "Customer Energy Management System" is divided into the following parts.

--- Part 1. Guidelines;

--- Part 2. Master station function specification;

--- Part 3-1. General requirements for subsystem interface gateways;

--- Part 3-2. Subsystem interface gateway data configuration;

--- Part 4. Master station system and subsystem interface gateway information exchange specification;

--- Part 5. External data interface specification for the primary station system;

--- Part 6. Management indicator system;

--- Part 7. Functional classification and system grading;

--- Part 8. Use cases;

---Part 9. Protection and safety requirements;

--- Part 10. System inspection specifications;

--- Part 11. Operational management and maintenance specifications;

--- Part 12. Energy efficiency indicators and assessment guidelines.

This part is the first part of GB/T 35031.

This part is drafted in accordance with the rules given in GB/T 1.1-2009.

1 Scope

This part of GB/T 35031 specifies the relationship model between the customer-side energy management system and the energy supplier and energy service provider, and the client.

The overall requirements for the energy management system interoperability architecture and the security protection of the customer-side energy management system.

This section is applicable to guide the design, development, construction, operation and maintenance and management of the energy management system at the customer end.

Note: The user side uses various forms of energy including electricity, water, gas, heat, and cold. Electrical energy is the most commonly used form of energy for the user, and its information management is for users.

Other energy sources are representative. For the sake of brevity, the requirements of this part of the user-side energy management system are mainly described by electric energy sources.

But not limited to power energy management, it is also applicable to the management of other energy sources.

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this document. For undated references, the latest edition (including all amendments) applies to this document.

GB 17859-1999 Computer Information System Security Protection Level Division Guidelines

GB/T 22239-2008 Information security technology information system security level protection basic requirements

GB /Z 32500-2016 General requirements for data interface of smart grid client system

GB /Z 32501-2016 General requirements for smart grid customer communication systems

3 Terms and definitions, abbreviations

3.1 Terms and definitions

The following terms and definitions defined in GB /Z 32500-2016 and GB /Z 32501-2016 apply to this document.

3.1.1 Representational state transfer

A software architecture design and development style for web applications.

Note 1. REST is based on the HTTP protocol, and any operation on resources is implemented through the HTTP protocol. When a uniform resource identifier When a (URI) conforms to the REST architectural style, this URI is called RESTful.

Note 2. The RESTful design guidelines are.

1) Everything on the network is abstracted into resources;

2) Each resource corresponds to a unique URI;

3) operate on resources through a common connector interface;

4) The various operations on the resource do not change the URI;

5) All operations are stateless.

3.1.2 Participant

Communication and interaction entities.

Note: Participants can be people, software applications, systems, databases, or even CEMS itself.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 35031.1-2018

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 35031.1-2018

$185.00