Valid

GB/T 33647-2017Determination of silicon content in motor gasoline—Inductively coupled plasma optical emission spectrometry (ICP-OES) (English PDF)

车用汽油中硅含量的测定 电感耦合等离子体发射光谱法

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 33647-2017 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

May 12, 2017

Implementation date

December 1, 2017

Scope

GB/T 33647-2017 is the English-translated version of 车用汽油中硅含量的测定 电感耦合等离子体发射光谱法.

GB/T 33647-2017 determines the silicon content of motor gasoline by inductively coupled plasma optical emission spectrometry.

It covers silicon from 1.0 mg/kg to 50.0 mg/kg in gasoline whose oxygen-containing compounds do not exceed 15 % by volume: gasoline with methyl tert-butyl ether, M15 methanol gasoline and E10 ethanol gasoline; a richer sample may be diluted with isooctane, but that route has no established precision.

Sulfur, lead, iron, manganese, phosphorus and chlorine in the gasoline do not interfere with the silicon result.

It sets out the apparatus, the reagents - isooctane, an organosilicon standard such as hexamethyldisiloxane, argon and oxygen of at least 99.995 % purity and 10 % nitric acid - the calibration, the procedure, the calculation, the quality control and the test report. It was issued on 12 May 2017 and has applied since 1 December 2017.

Found what you need?

Document preview — GB/T 33647-2017

National Standard of the People's Republic of China

ICS
75.160.20
Classification
E 30

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword3
  • Introduction4
  • 1 Scope5
  • 2 Normative References5
  • 3 Method Summary6
  • 4 Interference6
  • 5 Apparatus6
  • 6 Reagents and Materials7
  • 7 Sampling8
  • 8 Preparation of Standard Solution and Specimen Solution8
  • 9 Apparatus Preparation8
  • 10 Calibration9
  • 11 Test Procedures9
  • 12 Result Calculation10
  • 13 Quality Control10
  • 14 Precision10
  • 15 Test Report11
  • Bibliography12

Foreword

This Standard was drafted as per the rules specified in GB/T 1.1-2009.

1 Scope

This Standard specifies the test method of adopting the inductively coupled plasma optical emission spectrometry (ICP-OES) to determine the silicon content in motor gasoline.

This Standard is applicable to determine the silicon content of 1.0mg/kg ~ 50.0mg/kg in the motor gasoline (the volume fraction of oxygen-containing compounds shall not exceed 15%), such as motor gasoline containing methyl tert-butyl ether, motor methanol gasoline (M15) and motor ethanol gasoline (E10). For the motor gasoline sample with silicon content higher than 50.0mg/kg, it can be diluted by the isooctane with higher proportion, then determine according to this Standard method; but its precision has not been statistics yet.

When testing according to this Standard, some elements in the motor gasoline like sulfur, lead, iron, manganese, phosphorus and chlorine shall not interfere the determination results of the silicon content.

2 Normative References

The following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document; for the undated documents, only the latest version (including all the amendments) are applicable to this document.

GB/T 4756 Method for Manual Sampling of Petroleum Liquids

GB/T 17476 Standard Test Method for Determination of Additive Elements, Wear Metals, and Contaminants in Used Lubricating Oils and Determination of Selected Elements in Base Oils by Inductively Coupled Plasma Optical Emission Spectrometry

5 Apparatus

5.3 Peristaltic pump (recommended)

In order to provide stable sample injection operation, it is recommended to use peristaltic pump for sample injection, the pump speed range is of 0.5mL/min ~ 3mL/min.

5.4 Sample injection tube of peristaltic pump

The use of sample injection tube of peristaltic pump shall ensure when contact with the organic solvent (diluent) for at least 6h, it is exempted from swelling, dissolving, deforming, hardening, and the like appearance changes; it is recommended to use synthetic rubber tube.

5.5 Specimen container

30mL ~ 120mL plastic bottle or glass bottle with threaded cap.

5.6 Balance

Accurate to 0.0001g.

6 Reagents and Materials

6.1 Isooctane. analytically pure.

6.2 Silicon organic standard material. prepare or purchase the silicon organic standard solution with concentration no less than 500mg/kg; for instance, dilute the hexamethyldisiloxane with purity greater than 99% with isooctane, then prepare the 1000mg/kg silicon organic standard solution.

NOTE: for the motor gasoline sample with silicon content greater than 100mg/kg, it is more suitable to use hexamethyldisiloxane as standard material; while the base oil-based silicon organic standard solution may result in higher test results.

6.3 Argon, oxygen. purity no less than 99.995% (volume fraction).

6.4 10% (mass fraction) nitric acid solution.

6.5 Quality control (QC) sample. select the motor gasoline with the similar silicon content as to-be-tested motor gasoline as the quality control sample, it can also be obtained by diluting the proper amount of silicon organic standard material with isooctane. The quality control sample is recommended to seal in the glass bottle with threaded cap, and store in the dark at less than 10°C environment.

11 Test Procedures

11.2 The blank solution and specimen solution shall be measured for three repeated times. The average blank response value shall be subtracted from the signal response value of each specimen solution before determining the average response value of silicon in the specimen solution.

12 Result Calculation

The silicon content X [in (mg/kg)] in the motor gasoline sample shall be calculated by Formula (1).

Where:

Ic - average response value of silicon in specimen solution;

Ibk - average response value of blank solution;

S - standard curve slope (kg/mg);

Kg - mass dilution factor, namely, sample mass/ total mass of sample plus dilution solvent (g/g).

13 Quality Control

13.1 Determine the quality control sample's average value and control limit before use the quality control sample.

13.2 It is recommended to use quality control sample to check once every day when the sample is measured. When measuring large quantities of samples, increase the inspection frequency of quality control sample.

13.3 If the obtained results exceed the control limit, in order to ensure the accuracy of the test results, re-calibrate the instrument and re-measure the sample.

14 Precision

14.1 Overview

According to the method in GB/T 6683, the precision of this Standard was obtained through the test results of 5 motor gasoline samples with silicon content of 1.0mg/kg ~ 50.0mg/kg in 12 collaborative laboratories. The instruments used in the collaborative laboratories are equipped with oxygenating device and atomization chamber cooling […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 33647-2017

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 33647-2017

$105.00