GB/T 26216.2-2019 is the English-translated version of 高压直流输电系统直流电流测量装置 第2部分:电磁式直流电流测量装置.
GB/T 26216.2-2019 sets the requirements for electromagnetic DC current measuring devices used in HVDC transmission systems of ±1100 kV and below. As Part 2 of GB/T 26216, it covers the normal and special service conditions, the ratings, the design and construction, the tests and the markings.
The ratings it fixes are the rated primary DC current, the overload current, the short-time current rating, the rated primary voltage, the maximum continuous operating voltage, the insulation level, the accuracy class of the whole device and the rated value of the analogue output, while the design clauses deal with electrical shielding, corrosion protection, the analogue voltage output and SF6-filled and oil-filled equipment.
The tests are grouped into type, routine, field and special tests. It replaces GB/T 26216.2-2010, was issued on 10 December 2019 and has applied since 1 July 2020.
Found what you need?
Document preview — GB/T 26216.2-2019
National Standard of the People's Republic of China
- ICS
- 29.180
- Classification
- K 41
- Replacing
- GB/T 26216.2-2010
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Normal and special conditions of use
- 5 Rating
- 5.1 Rated primary DC current (Ir)
- 5.2 Overload current
- 5.3 Short-time current rating
- 5.4 Rated primary voltage (Udr)
- 5.5 Maximum continuous operating voltage (Udm)
- 5.6 Insulation level
- 5.7 Accuracy level of the entire current measuring device
- 5.8 Rated value of analog output
- 6 Design and structure
- 6.1 General requirements
- 6.2 Electrical shielding
- 6.3 Corrosion protection
- 6.4 Design requirements for analog voltage output
- 6.5 Charge SF6 device
- 6.6 Oil-filled equipment
- 7 Test
- 7.1 Test classification
- 7.2 General conditions of the test
- 7.3 Type test
- 7.4 Routine test
- 7.5 Field test
- 7.6 Special tests
- 8 signs
- 8.1 Terminal Markings
- 8.2 Nameplate logo
Foreword
GB/T 26216 "DC Current Measurement Device for HVDC Transmission System" is divided into two parts.
--- Part 1. Electronic DC current measuring device;
--- Part 2. Electromagnetic DC current measuring device.
This part is the second part of GB/T 26216.
This section is drafted in accordance with the rules given in GB/T 1.1-2009.
This section replaces GB/T 26216.2-2010 "DC current measurement devices for high-voltage DC transmission systems. Part 2. Electromagnetic DC". Compared with GB/T 26216.2-2010, the main technical changes are as follows.
--- Amend "800" to "1100", "± 800kV and below voltage level DC transmission system DC pole bus, double twelve pulsation switching Electromagnetic DC current measuring device for the midpoint (if applicable) busbar and neutral busbar of the flow valve group. "To" ± 1100kV and Electromagnetic DC current measurement devices for DC voltage transmission systems of the following voltage levels, typically arranged at neutral busbars and ground terminals Line etc. "(See Chapter 1, Chapter 1 of the 2010 edition);
--- Change the rated primary DC current value "600A, 3000A, 3125A, 4000A, 4500A." To "500A, 630A, 800A, 1000A, 1250A, 1600A, 2000A, 2500A, 3150A, 4000A, 5000A, 6300A." (see 5.1, 5.1 of the 2010 version);
--- Modify the title of the "overload DC current" to "overload current" (see 5.2, 5.2 of the 2010 version);
--- Modify "Rated Voltage" to "Rated Primary Voltage", where the values "408kV, 515kV, 680kV, 816kV" are modified "400kV, 500kV, 660kV, 800kV", and increase the value "1100kV" (see 5.4, 2010 version 5.4);
--- Increased the "maximum continuous operating voltage" see (5.5);
--- In Table 1, "rated voltage" was modified to "maximum continuous operating voltage" and the corresponding voltage value was modified. DC withstand voltage value in the table "1200" was changed to "1224" and "1122" and its corresponding value were added (see 5.6, 5.5 of the 2010 version);
--- Respecified the current error value in Table 2 (see 5.7, 5.8 of the 2010 version);
--- Deleted the "rated value of digital output" (see 5.9 in the 2010 version);
--- Removed the "nameplate logo" (see 6.4 of the 2010 version);
--- Deleted the "design requirements for digital output" (see 6.5 of the 2010 version);
--- "150 x 10^-6" was modified to "250", and "(including gas density relay, pressure indicator and temperature indicator)" was deleted (see 6.5, 6.7 of the 2010 version);
--- Deleted the "test group" and moved part of it into the type test project (see 7.3.2.1, 7.3.2 of the 2010 version);
--- Added "accuracy test, current step response test, frequency response test, dry heat test, high current test, Effect of high-frequency current on the interlock circuit, electromagnetic compatibility test "(see 7.3.2.1, 7.3.3 of the 2010 edition);
--- The content of the temperature rise test is modified to "The temperature rise test is carried out in accordance with 7.2.2 regulations and criteria of GB/T 20840.2-2014." (See 7.3.2.3, 7.3.3.2 of the 2010 version);
--- Modify "Ud < 200" to "Udm < 300" and "Ud>=200" to "Udm>=300" (see 7.3.2.4, 7.3.3.3 of the 2010 version);
--- Modify "positive DC voltage" to "negative DC voltage" (see 7.3.2.6, 7.3.3.5 of the 2010 version);
--- Deleted the "step response" and used its content as the criterion for the current step response test (see 7.3.2.12, 2010 version 5.7);
--- Deleted the "frequency response" and used its content as the criterion for the frequency response test (see 7.3.2.13, 2010 version 5.6);
--- Deleted the "test of electronic equipment" (see 7.3.4 of the 2010 version);
--- Deleted the "complementary type test of digital output" (see 7.3.4.8 of the 2010 version);
--- Modify "250 x 10^-6" to "250" and "66kV" to "60kV" (see 7.5.8, 7.5.7 of the 2010 version);
--- "Leak point for qualitative leak detection, quantitative leak detection if in doubt, annual leakage rate should be less than 0.5%." Amended to "SF6 gas absolute The method for checking the tightness of the edge DC current measuring device is performed in accordance with the regulations and criteria of GB/T 11023." (See 7.5.9, 2010 version 7.5.8);
--- Added "flags" (see Chapter 8);
--- Removed the Appendix A of the 2010 edition.
1 Scope
This part of GB/T 26216 specifies the specifications of electromagnetic DC current measuring devices for DC power transmission of voltage levels of ± 1100kV and below. Normal and special use conditions, ratings, design and construction, tests, etc.
This section applies to electromagnetic DC current measurement devices installed in DC power transmission systems with voltage levels of ± 1100kV and below. Typical The layout location is neutral bus, ground electrode lead, etc.
2 Normative references
The following documents are essential for the application of this document. For dated references, only the dated version applies to this document. For undated references, the latest version (including all amendments) applies to this document.
GB/T 311.1-2012 Insulation coordination Part 1: Definitions, principles and rules
GB/T 2423.2 Environmental tests for electric and electronic products. Part 2. Test methods Test B. High temperature
GB/T 2424.25 Environmental testing for electric and electronic products-Part 3: Test guidelines-Earthquake test methods
GB/T 2900.50 Electrical terminology General terminology for power generation, transmission and distribution
GB/T 2900.57 Electrical terminology for power generation, transmission and distribution operation
GB/T 2900.95 Electrical terminology transformers, voltage regulators and reactors
GB/T 7354 High Voltage Test Technology Partial Discharge Measurement
GB/T 11023 Sulfur hexafluoride gas seal test method for high voltage switchgear
GB/T 16927.1 High voltage test technology-Part 1: General definition and test requirements
GB/T 20840.1-2010 transformers Part 1: General technical requirements
GB/T 20840.2-2014 Transformers Part 2: Supplementary technical requirements for current transformers
GB/T 20840.8-2007 Current transformers Part 8: Electronic current transformers
GB/T 22071.1 Test Guide for Transformers Part 1: Current Transformers
GB/T 22707 Artificial pollution test for high-voltage insulators for DC systems
GB 50150-2016 electrical equipment installation engineering electrical equipment handover test standard
3 Terms and definitions
GB/T 2900.50, GB/T 2900.57, GB/T 2900.95 and GB/T 20840.1-2010 and the following terms and definitions The meaning applies to this document.
3.1 DC current measuring device
A device that provides a signal corresponding to the DC current of the primary circuit. The output signal is provided to measuring instruments, meters and protection or control equipment.
3.2 Electromagnetic DC current measuring device
The primary sensor uses the electromagnetic induction principle to provide a signal corresponding to a DC current, and the signal is directly sent to the […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 2423.2Environmental testing for electric and electronic products - Part 2: Test methods - Tests B: Dry heat
- GB/T 2424.25Environmental testing - Part 3: Test guidance - Seismic test methods
- GB/T 2900.50Electrotechnical terminology -- Generation, transmission and distribution of electricity -- General
- GB/T 2900.57Electrotechnical terminology -- Generation, transmission and distribution of electricity -- Operation
- GB/T 2900.95Electrotechnical terminology -- Transformers, voltage regulators and reactors
- GB/T 7354High-voltage test techniques -- Partial discharge measurements
GB/T 311.1-2012 · GB/T 20840.2-2014
Similar standards
Editions of GB/T 26216.2
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB/T 26216.2-2019 | DC current measuring device for HVDC transmission system—Part 2: Electromagnetic DC current measuring device | current edition | Current |
| GB/T 26216.2-2010 | DC current measuring device for HVDC transmission system—Part 2: Electromagnetic DC current measuring device | previous edition | Superseded |
This page sells the current edition, GB/T 26216.2-2019. Earlier editions are listed for reference only.
How to Download GB/T 26216.2-2019
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 50150-2016 — Electric equipment installation engineering-standard for hand-over test of electric equipment
GB/T 11023-2018 — Test method of SF6 gas tightness for high - voltage switchgear
GB/T 16927.1-2011 — High-voltage test techniques -- Part 1: General definitions and test requirements