GB/T 24841-2018Technical specification for capacitor voltage transformers of 1000kV AC system (English PDF)
1000kV交流系统用电容式电压互感器技术规范
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 24841-2018 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
July 13, 2018
Implementation date
February 1, 2019
Scope
GB/T 24841-2018 is the English-translated version of 1000kV交流系统用电容式电压互感器技术规范.
GB/T 24841-2018 is the Chinese technical specification for capacitor voltage transformers used in 1000 kV AC systems. It covers the conditions of use, the technical parameters and performance requirements, the structural requirements, the tests, and life expectancy, packaging, transport and storage.
It applies to transformers in AC systems with a nominal voltage of 1000 kV and a frequency of 50 Hz, and serves their selection, manufacture, testing and acceptance.
Its terms distinguish stacked and non-stacked structures, in which the capacitor divider and the electromagnetic unit are integrated or separate and connected through an outlet bushing, and also define breaking load and operating variation.
Informative annexes deal with special conditions of use and with transformers that also serve as post insulators. It was issued on 13 July 2018 and has applied since 1 February 2019.
Found what you need?
Document preview — GB/T 24841-2018
National Standard of the People's Republic of China
- ICS
- 29.180
- Classification
- K 41
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 4 Conditions of use
- 5 Technical parameters and performance requirements
- 6 Structural requirements
- 7 Test
- 8 Life expectancy, packaging, transportation and storage
- Appendix A (informative) Special conditions of use
- Appendix B (informative) Special requirements for capacitive voltage transformers for 1000kV AC systems used as post insulators
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard replaces GB /Z 24841-2009 "Technical Specifications for Capacitor Voltage Transformers for 1000kV AC Systems". Compared with GB /Z 24841-2009, the main technical changes except editorial changes are as follows.
--- Some of the referenced documents have been added and revised in the normative references (see Chapter 2, Chapter 2 of the 2009 edition);
--- Definition of damage load added to terms and definitions (see Chapter 3);
--- Revised the technical parameters in the rated output (see 5.1.6, 5.1.6 of the 2009 edition);
--- Revised the technical parameters in the accuracy class (see 5.1.7, 5.1.7 of the 2009 edition);
--- Revised the technical parameters in the temperature coefficient of the capacitor divider capacitor (see 5.1.10, 5.1.10 of the 2009 edition);
--- Revised some of the technical parameters in ferromagnetic resonance (see 5.2.1, 5.2.1 of 2009 edition);
--- Added and revised some of the technical parameters of the external insulation requirements (see 5.2.10, 5.2.10 of the 2009 edition);
--- Revised the number and parameters of the pressure equalizing ring in the pressure equalization device (see 6.3, 6.3 of the 2009 edition);
--- Increased the test items in the type test (see 7.2);
--- Revised the formula for calculating the altitude correction factor (see A.1, 2009 edition of A.1);
--- Revised the temperature range in ambient temperature (see A.2, 2009 edition of A.2);
--- Added special requirements for capacitive voltage transformers that double as post insulators (see Appendix B).
1 Scope
This standard specifies the use conditions, technical parameters and performance requirements, and structural requirements of capacitive voltage transformers for 1000kV AC systems. Requirements, tests, life expectancy, packaging, transportation and storage.
This standard is applicable to 1000kV capacitive voltage transformers used in AC systems with a nominal voltage of 1000kV and a frequency of 50Hz. Selection, manufacturing, testing and acceptance.
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this document. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 2900.16 Electrotechnical terminology power capacitor
GB/T 2900.50 Electrotechnical terminology General term for power generation, transmission and distribution
GB/T 2900.57 Electrotechnical terminology for power generation, transmission and distribution operation
GB/T 2900.94 Electrotechnical terminology transformer
GB/T 13540 high-voltage switchgear and control equipment for seismic requirements
GB/T 19749.1 Coupling capacitors and capacitor dividers - Part 1. General
GB/T 20840.1 Transformers - Part 1. General technical requirements
GB/T 20840.5 Transformers - Part 5. Supplementary technical requirements for capacitive voltage transformers
3 Terms and definitions
GB/T 2900.16, GB/T 2900.50, GB/T 2900.57, GB/T 2900.94, GB/T 20840.1, GB/T 20840.5 And the following terms and definitions apply to this document.
3.1 Stacked structure
The capacitive voltage divider and the electromagnetic unit are structurally integrated, and the piezoelectric divider and the electromagnetic unit are electrically connected internally.
3.2 Non-stacked structure
The capacitive voltage divider and the electromagnetic unit are structurally separated, and the capacitive voltage divider and the electromagnetic unit are externally electrically connected through the outlet bushing.
3.3 Breaking load
Vertically acting on the longitudinal axis of the porcelain sleeve or composite jacket transformer, resulting in mechanical damage to the transformer casing.
3.4 Running variation
The error is affected by the operating environment and can be caused by operating conditions such as ambient temperature, proximity effects, contamination, and the like.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 2900.16Electrotechnical terminology - Power capacitors
- GB/T 2900.50Electrotechnical terminology -- Generation, transmission and distribution of electricity -- General
- GB/T 2900.57Electrotechnical terminology -- Generation, transmission and distribution of electricity -- Operation
- GB/T 2900.94Electrotechnical terminology -- Instrument transformers
- GB/T 13540Seismic qualification for high voltage switchgear and controlgear
- GB/T 19749.1Coupling capacitors and capacitor dividers -- Part 1: General rules
Similar standards
How to Download GB/T 24841-2018
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 13540-2009 — Seismic qualification for high voltage switchgear and controlgear
GB/T 19749.1-2016 — Coupling capacitors and capacitor dividers -- Part 1: General rules
GB/T 20840.1-2010 — Instrument transformers-Part 1:General requirements
Secure payment via Stripe
Payments accepted
GB/T 24841-2018
$205.00