Valid

GB/T 20840.5-2013Instrument transformers -- Part 5: Additional requirements for capacitor voltage transformers (English PDF)

互感器 第5部分:电容式电压互感器的补充技术要求

Preview PDF

This is a limited preview

Buy now to download the full PDF (46 pages)

Need quotation for your management?

Get a formal quotation for GB/T 20840.5-2013 in 30 minutes.

Issued by

Standardization Administration of China

Level / Type

National · Recommended

Issue date

February 7, 2013

Implementation date

July 1, 2013

Scope

GB/T 20840.5-2013 is the English-translated version of 互感器 第5部分:电容式电压互感器的补充技术要求.

GB/T 20840.5-2013 — This section GB 20840 applies to newly manufactured single-phase line-to-ground capacitor voltage transformer, its highest voltage for equipment Um>=72.5kV, Frequency of 15Hz ~ 100Hz.

They provide low-voltage measurement, control and protection devices. Capacitor voltage transformers can be loaded wave accessory for the carrier frequency of 30kHz ~ 500kHz Power Line Carrier (PLC) system.

The basic requirements for coupling capacitors and capacitive voltage divider according to GB/T 19749. Power Line Carrier (PLC) combined transport equipment requirements According to GB/T 7329.

Measurement functions include measurements indicate that the measurement and billing. 501 Note. Appendix 5C shows the capacitor voltage transformer circuit diagram of an example of this section applies.

502 Note. If the user needs, the Um is 40.5kV capacitive voltage transformer can also be used in this section. Note 503. high frequency characteristics of the capacitor voltage transformer in Appendix 5D.

Found what you need?

Document preview — GB/T 20840.5-2013

National Standard of the People's Republic of China

ICS
29.180
Classification
K 41
Replacing
GB/T 4703-2007

Issued by: Standardization Administration of China

Contents

  • Introduction
  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 3.1 General definitions
  • 3.2 Definitions for electrical insulation and voltage ratings of
  • 3.4 Concerning the definition of accuracy
  • 3.5 For definitions of the other 7 ratings
  • 7 3.7 Symbols and names
  • 8 5 Rating
  • 8 5.2 Highest voltage for equipment
  • 5.3 Rated insulation level
  • 5.4 Rated frequency
  • 5.5 Rated output
  • Accuracy class 5.6 rated
  • 5.501 Rated voltage standard value of
  • 6 Design and construction
  • 6.1 Equipment required liquid with
  • 6.7 The mechanical strength requirements
  • 6.8 Times a truncated end impact
  • 6.9 Internal arc fault protection requirements
  • 6.13 Mark
  • 6.501 Short circuit withstand capability
  • 6.502 Ferroresonance
  • 6.503 Transient Response
  • 6.504 Annex 21 requires carriers
  • 7 Test
  • 7.1 General
  • 7.2 Type tests
  • 7.3 Routine tests
  • 36 7.4 Special tests
  • Appendix 5A (informative) of this section with IEC 61869-5. structural changes in 2011 compared to
  • Appendix 5B (informative) of this section with IEC 61869-5:2011 technical differences and their causes
  • Appendix 5C (normative) capacitor voltage transformer circuit diagram illustrating
  • High-frequency characteristics Appendix 5D (normative) capacitive voltage transformer
  • Appendix 5E (Informative Appendix) IEC 61869-5:2011 Electromagnetic unit insulation level, rated secondary voltage and for generating surplus
  • The rated voltage of the secondary winding voltage
  • Appendix 5F (Informative Appendix) under fault conditions capacitor voltage transformer another transient response

Foreword

GB 20840 "transformer" intends divided into the following sections.

--- Part 1. Common technical requirements;

--- Part 2. additional technical requirements current transformer;

--- Part 3. Supplementary technical requirements of electromagnetic voltage transformer;

--- Part 4. Combined Transformer additional technical requirements;

--- Part 5. additional technical requirements for capacitor voltage transformer;

--- Part 6. electronic transformer and low power independent of the sensor complement common technical requirements;

--- Part 7. Electronic voltage transformers supplementary technical requirements;

--- Part 8. Electronic current transformers additional technical requirements;

--- Part 9. Transformer digital interface;

--- Part 10. Supplementary independent current sensor technology low power requirements;

--- Part 11. Low-power complementary technologies independent voltage sensor requirements;

--- Part 12. Combined electronic transformer and complementary combination of technical requirements independent of the sensor;

--- Part 13. Independent merge cells.

This is Part 5 GB 20840's.

This section drafted in accordance with GB/T 1.1-2009 given rules.

This Part replaces GB/T 4703-2007 "capacitor voltage transformers." this section needs with GB 20840.1-2010 "transformers - Part 1. General technical requirements" supporting the use of. This section follows the GB 20840.1 of the preparation of the structure, is a supplement corresponding provisions of GB 20840.1, modification or replacement. When the terms of GB 20840.1 in the present Section not to mention timely, as long as reasonable, those terms would apply to this section. When specified in this section, "add", "modification" or "replacement" when, it means that the relevant provisions of GB 20840.1 in this section is adapted accordingly.

For Zhang, bars, graphs, tables, notes and appendix in GB 20840.1-2010 based on additions, this section uses the following forms of ID.

--- Chapter, bar, graphs, tables, and note the number 501 from the beginning;

--- Appendix No. 5A, 5B and the like.

This section uses redrafted law revision using IEC 61869-5:2011 "Transformers Part 5. Capacitor voltage transformers supplementary skills requirement".

This part of IEC 61869-5:2011, compared with more adjustment in the structure, are listed in Appendix 5A of this section with IEC 61869-5.

Chapter, article, figure, table number 2011 of the control list.

Technical differences exist compared to 2011, the terms of these differences have been involved through gaps in its outer margin. This part of IEC 61869-5 A single vertical line at position (|) have been identified in Appendix 5B are given a list of corresponding technical differences and their causes.

This section also made the following editorial changes.

--- Increasing the "Introduction";

--- Remove the IEC 61869-5:2011 5.3.5,7.2.3.3.1 and 7.3.8 of the section heading and the contents 7.2.3.3.1 Variable 7.2.3.3 for the contents of;

--- The IEC 61869-5:2011 is 5.3.501 and 7.3.1.504.1 (This section 7.3.2.504.1) public expression by text Formula to formula expressed by the symbol, and symbols are explained for each formula;

--- The IEC 61869-5. 7.3.1.502 2011's (This section 7.3.2.502) and 7.3.2.2 (This section 7.3.3.2) with Formula written expression changed in narrative form;

--- Increase the informative appendix 5E, the IEC 61869-5. Electromagnetic unit insulation level has not been adopted in 2011, rated secondary voltage and for generating a residual voltage of the secondary winding voltage rating listed in the Appendix.

Please note that some of the content of this document may involve patents. Release mechanism of the present document does not assume responsibility for the identification of these patents.

This part is proposed by the China Electrical Equipment Industrial Association.

This part of the National Standardization Technical Committee transformers (SAC/TC222) centralized.

This section is drafted. Shenyang Transformer Research Institute Co., Ltd., State Grid Electric Power Research Institute, Tohoku Electric Power Research Institute shares Parts Limited, Xi'an Electric Power Capacitor Co., Ltd., Guilin Power Capacitor Co., Ltd., TBEA Kangjia (Shenyang) Transformer Co., Ltd., Shanghai MWB Transformer Co., Ltd., Nissin Electric (Wuxi) Co., Ltd., Dalian first transformer limited liability any company, Zhongshan City, Thailand Electric Co., Ltd., Dalian Northern Transformer Group Co., Ltd. Dalian transformer.

Introduction

IEC/TC38 standard system has been realigned, before the upcoming IEC 60044 series of standards is now readjusted IEC 61869 series of standards. In order to better use of international standards, the National Standardization Technical Committee transformers (SAC/TC222) The study Decided to our current system of national standards Transformer also press IEC/TC38 new standard system be realigned before the upcoming the individual transformers to national standards IEC 60044 series of standards by the corresponding relationship between IEC 61869 series of standards correspond to re Develop, constitute a "common technical requirements" general part and each "Supplementary technical requirements" section dedicated supporting new Transformers series Country standard.

New national standards for transformers intended to form the overall situation is as follows.

General part of the standard number and name Special section Standard Dedicated part of the standard name corresponding Original Standard GB 20840.1 General technical requirements GB 20840.6 Electronic Transformers and low power alone Supplementary pass legislation sensor Technical Requirements Supplementary technical requirements GB 20840.2 current transformer GB 1208 GB 16847 Complementary technology GB 20840.3 Electromagnetic Voltage Transformer requirements GB 1207 GB 20840.4 Combined Transformer supplementary technical requirements of GB 17201 GB/T 20840.5 additional technical requirements for capacitor voltage transformers GB/T 4703 GB 20840.7 additional technical requirements for electronic voltage transformer GB/T 20840.7 Supplementary technical requirements GB 20840.8 electronic current transformer GB 20840.9 Transformer Digital Interface Supplementary technical requirements GB 20840.10 low power independent current sensor GB/T 20840.8 GB 20840.11 complementary technologies independent low power voltage sensor requirements GB/T 20840.7 GB 20840.12 Complement combination electronic transformer and combinations of independent sensors Charge technical requirements GB 20840.13 merge independent unit -Transformers - Part 5. Capacitor Voltage Transformer Additional technical requirements

1 Scope

This section GB 20840 applies to newly manufactured single-phase line-to-ground capacitor voltage transformer, its highest voltage for equipment Um>=72.5kV, Frequency of 15Hz ~ 100Hz. They provide low-voltage measurement, control and protection devices.

Capacitor voltage transformers can be loaded wave accessory for the carrier frequency of 30kHz ~ 500kHz Power Line Carrier (PLC) system.

The basic requirements for coupling capacitors and capacitive voltage divider according to GB/T 19749. Power Line Carrier (PLC) combined transport equipment requirements According to GB/T 7329.

Measurement functions include measurements indicate that the measurement and billing.

501 Note. Appendix 5C shows the capacitor voltage transformer circuit diagram of an example of this section applies.

502 Note. If the user needs, the Um is 40.5kV capacitive voltage transformer can also be used in this section.

Note 503. high frequency characteristics of the capacitor voltage transformer in Appendix 5D.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. Who does not note date reference documents, the latest edition (including any amendments) applies to this document.

Chapter 2 GB 20840.1-2010 content with the following additions apply.

GB/T 156 standard voltage (GB/T 156-2007, IEC 60038:2002, IEC StandardVoltages, MOD) GB 311.1 insulation coordination - Part 1. Definitions, principles and rules (GB 311.1-2012, IEC 60071-1:2006, MOD) GB/T 2900.15 Electrotechnical terminology transformers,, regulators and reactors (GB/T 2900.15-1997, IEC 60050 (421).1990; IEC 60050 (321). 1986, NEQ) GB/T 2900.16 Electrotechnical terminology - Power capacitors (GB/T 2900.16-1996, IEC 60050 (436).1990, NEQ) GB/T 2900.50 Electrotechnical terminology Generation, transmission and distribution of generic terms (GB/T 2900.50-2008, IEC 60050 (601). 1985, MOD) GB/T 2900.57 Electrotechnical terminology Generation, transmission and distribution operations (GB/T 2900.57-2008, IEC 60050 (604).

1987, MOD)

GB/T 5585.1 electrician with copper, aluminum and its alloy bus - Part 1. Copper and copper alloy bus GB/T 7329 Power Line Carrier binding device (GB/T 7329-2008, IEC 60481. 1974, NEQ) Transformer oil quality GB/T 7595 running GB/T 19749 coupling capacitors and capacitive voltage divider (GB/T 19749-2005, IEC 60358:1990, MOD) GB 20840.1-2010 transformers - Part 1. General Requirements (IEC 61869-1:2007, MOD)

3 Terms and Definitions

GB 20840.1-2010, GB/T 2900.50 and GB/T 2900.57 and as defined in the following terms and definitions are appropriate additions Used in this document.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 46 pages — is available in the English PDF.

Referenced standards

Normative references

IEC 60038 · IEC 60071 · GB/T 2900.15 · GB/T 2900.15-1997 · IEC 60050 · GB/T 2900.57 · GB/T 2900.57-2008 · GB/T 7329 · GB/T 7329-2008 · IEC 60481 · IEC 60358 · IEC 61869

How to Download GB/T 20840.5-2013

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
46 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 20840.5-2013

$725.00