GB/T 19749.1-2016Coupling capacitors and capacitor dividers -- Part 1: General rules (English PDF)
This is a limited preview
Buy now to download the full PDF (29 pages)
Need quotation for your management?
Get a formal quotation for GB/T 19749.1-2016 in 30 minutes.
Issued by
Standardization Administration of China
Level / Type
National · Recommended
Issue date
February 24, 2016
Implementation date
September 1, 2016
Scope
GB/T 19749.1-2016 (Coupling capacitors and capacitor dividers -- Part 1: General rules) is available as an English-translated PDF.
GB/T 19749.1-2016 — This section GB/T 19749 specifies the terms and definitions signs coupling capacitors and capacitive voltage divider, conditions, ratings, design requirements, test conditions, test classification, routine tests, type testing, special tests and equipment.
This section applies to the rated voltage 1000V or more, connected between the line and the ground voltage terminal permanently grounded or connected to the device for the following applications and other similar uses capacitors.
This section is based on the standard of the coupling capacitor, supplementary provisions and test GB/T 19749.2, GB/T 19749.3 and GB/T 19749.4 is given as in other parts of this standard.
Note. This section applies to the coupling capacitor of a typical example is shown in Figure A.1.
Found what you need?
Document preview — GB/T 19749.1-2016
National Standard of the People's Republic of China
- ICS
- 31.060.70
- Classification
- K 42
- Replacing
- GB/T 19749-2005
Issued by: Standardization Administration of China
Contents
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 3.1 General terms and definitions
- 3.2 Terms and definitions coupling capacitor
- Conditions 4
- 4.1 Overview
- 4.2 6 normal conditions of use
- 4.3 Special conditions
- 4.4 Grounding
- 5 8 ratings
- 5.1 Rated frequency standard value of
- 5.2 Rated voltage standard value of
- 5.3 Rated voltage factor standard values
- 6 9 design requirements
- 6.1 Insulation requirements
- 6.2 Other insulation requirements
- 6.3 Electromagnetic emission requirements - radio interference voltage (RIV)
- 6.4 Mechanical requirements
- 6.5 Sealing device
- 6.6 DC capacitor equalizing measures
- 7 Test conditions
- 8 Test Category
- 8.1 Overview
- 8.2 Routine tests
- 8.3 Type tests
- 8.4 Special tests
- 9 Routine tests
- 9.1 Tightness test
- 9.2 Electrical routine tests
- 10 Type tests
- 10.1 Impact test
- Wet 10.2 outdoor equipment test
- 10.3 Radio interference voltage test
- Polarity inversion 10.4 DC device test
- 11 Special tests - mechanical strength test
- 12 Flag device
- 12.1 Overview
- 12.2 Nameplate sign
- A typical example of FIG Appendix A (informative) device
- Annex B (informative) partial discharge test circuit and test instruments
- Annex C (normative) Radio interference voltage - measuring circuit
- References
Foreword
GB/T 19749 "coupling capacitors and capacitive voltage divider" intends divided into the following four parts.
--- Part 1. General;
--- Part 2. connected between the line and ground for power line carrier (PLC) of the single-phase AC or DC coupling capacitor;
--- Part 3. harmonic filters for AC or DC coupling capacitors;
--- Part 4. (except GB/T 20840.5 included CVT) connected between the line and ground single-phase AC or DC capacitive voltage divider and RC- divider.
This section GB/T 19749 Part 1.
This section drafted in accordance with GB/T 1.1-2009 given rules.
This Part replaces GB/T 19749-2005 "coupling capacitors and capacitive voltage divider." Compared with GB/T 19749-2005, in addition to editorial changes outside the main technical changes are as follows.
--- Revised Normative contents of the file (see Chapter 2, 2005 edition 1.2);
--- The terms and definitions are divided into "general terms and definitions" and "coupling capacitors Terms and definitions" (see 3.1 and 3.2);
--- Added "equipment," "frequency standard reference range" and other terms and definitions 20 (see Chapter 3);
--- Deleted "Capacitive Voltage Transformer" and other terms and definitions 14 (see the 2005 edition 1.3);
--- Added "other conditions within the user equipment" (see 4.2.4);
--- Increased requirements DC device (see 3.1.6, etc.);
--- Added "System Grounding" (see 4.4);
--- Remove the "acceptance test" (see 2005 2.2.3);
--- Increasing the "special test" (see 8.4);
--- Added "DC resistance measurement device" "radio interference voltage test" "test DC polarity inversion device" [see 8.2e) and 8.3h) and 8.3i)];
--- Modify the routine tests and type tests, the test flow provisions (see Chapter 9, 2, Chapter 2, 2005 edition of Chapter 10 and FIG.);
--- Added "partial discharge test circuit and detection equipment" (see Appendix B);
--- Added "Radio interference voltage - measurement loop" (see Appendix C).
This section uses redrafted law revision using IEC 60358-1:2012 "coupling capacitors and capacitor dividers - Part 1. General" (in English). This part of IEC 60358-1:2012 and its main technical differences for the following reasons.
--- On normative references, this part has been adjusted technical differences, in order to adapt our technical conditions, adjust the focus reflected in Chapter 2, "Normative references", the specific adjustments are as follows.
- Added references GB/T 26218.1-2010;
- Added references GB/T 26218.2-2010;
- Added references GB/T 26218.3-2011.
--- Taking into account international standards and voltage levels of different voltage levels according to GB 311.1-2012 given the appropriate content has also been modified.
--- Altitude correction reference GB 311.1-2012, according to the actual situation has been modified.
This part of IEC 60358-1:2012 clause above main difference has been involved through a single vertical line (-) blank space at the outside edges of the pages marked.
This section incorporates IEC 60358-1:2013 errata content, terms concerning these corrections have been through a vertical wire (||) its outer margin positions were marked 2012/cor.1.
For ease of use, this section also made the following editorial changes.
--- According to the rules GB/T 1.1-2009 given some written format and layout has been modified;
--- "This part" instead of IEC 60358-1:2012 in the "standard" word;
"." --- With a decimal point instead of the original IEC standard as a decimal comma ",";
--- Remove the IEC 60358-1:2012 Foreword.
Please note that some of the content of this section may involve patents. This part of the release mechanism does not assume the responsibility to identify these patents.
This part is proposed by the China Electrical Equipment Industrial Association.
This part of the National Standardization Technical Committee Power capacitor (SAC/TC45) centralized.
This section is drafted. Xi'an High Voltage Apparatus Research Institute Co., Ltd., Xi'an Electric Power Capacitor Co., Ltd., Guilin Power Capacitor Co., Ltd., Nissin Electric (Wuxi) Co., Ltd., Hefei Warwick Automation Co., Ltd., Zibo Leybold Power Capacitor Co., Ltd., Anhui Electric Power Research Institute, New Northeast Electric Group Power Capacitor Co., Ltd., Shanghai MWB Transformer Co., Ltd., Dandong Xintai Electric Co., Ltd., Xiamen Farah Electronics Co., Ltd., and Shenzhen City power Technology Co., Ltd.
This part drafters. HE tide, Zhao Xin, room sworn, Jia Hua, Wang Xiangfang, Mok Wah Ming, Sun Min, Jiang Jun Xiang, Ma Feng, Liu Jing, Tian Enwen, Huxue Bin, Ge Jinping, PAN Hong-mei, Yu Li Ying, Tanyan Min, Huang Shun Tat, Lu Tao, Zhang Chu Yan, Zhang Jinbo, Wang Yu Jing.
This part of the standard replaces the previous editions are.
--- GB/T 19749-2005.
Coupling capacitors and capacitive voltage divider Part 1. General
1 Scope
This section GB/T 19749 specifies the terms and definitions signs coupling capacitors and capacitive voltage divider, conditions, ratings, design requirements, test conditions, test classification, routine tests, type testing, special tests and equipment.
This section applies to the rated voltage 1000V or more, connected between the line and the ground voltage terminal permanently grounded or connected to the device for the following applications and other similar uses capacitors.
This section is based on the standard of the coupling capacitor, supplementary provisions and test GB/T 19749.2, GB/T 19749.3 and GB/T 19749.4 is given as in other parts of this standard.
Note. This section applies to the coupling capacitor of a typical example is shown in Figure A.1.
2 Normative references
The following documents for the application of this document is essential. For cited documents with dates, only the dated edition applies to this document. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 156 standard voltage (GB/T 156-2007, IEC 60038:2002, MOD) GB 311.1-2012 insulation coordination - Part 1. Definitions, principles and rules (IEC 60071-1:2006, MOD) GB/T 311.3-2007 insulation coordination - Part 3. HVDC converter station insulation coordination procedures (IEC/T S 60071-5.2002, MOD) GB/T 2423.23 Environmental testing Part 2. Test methods - Test Q. Sealing (GB/T 2423.23-2013, IEC 60068-2-17:1994, IDT) GB/T 4796 Classification of environmental conditions for electric and electronic products - Part 1. Environmental parameters and their severities (GB/T 4796-2008, IEC 60721-1:2002, IDT) GB/T 4797 series of electric and electronic natural environmental conditions [IEC 60721-2 (all parts), MOD] GB/T 4798 series of electric and electronic applications of environmental conditions [IEC 60721-3 (all parts), MOD] GB/T 7354 partial discharge measurements (GB/T 7354-2003, IEC 60270:2000, IDT) GB/T 16927.1 High-voltage test techniques - Part 1. General definitions and test requirements (GB/T 16927.1-2011, IEC 60060-1:2010, MOD) GB/T 26218.1-2010 under filthy conditions using high voltage insulator selection and sizing - Part 1. Definitions, information and general principles (IEC 60815-1:2008, MOD) GB/T 26218.2-2010 under filthy conditions using high voltage insulator selection and sizing Part 2. AC system with porcelain and glass insulators (IEC 60815-2:2008, MOD) GB/T 26218.3-2011 under filthy conditions using high voltage insulator selection and sizing Part 3. composite insulators for ac systems (IEC/T S60815-3.2008, MOD) CISPR/T R18-2 radio disturbance characteristics of overhead power lines and high voltage equipment - Part 2. Measuring methods and limits determination procedures
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 29 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 156Standard voltages
- GB/T 156-2007Standard voltages
- GB 311.1-2012Insulation co-ordination -- Part 1: Definitions, principles and rules
- GB/T 311.3-2007Insulation co-ordination -- Part 3: Procedures for high-voltage direct current (HVDC) converter stations
- GB/T 2423.23Environmental testing - Part 2: Test methods - Test Q: Sealing
- GB/T 2423.23-2013Environmental testing - Part 2: Test methods - Test Q: Sealing
IEC 60038 · IEC 60071 · IEC 60068 · GB/T 4796 · GB/T 4796-2008 · IEC 60721 · GB/T 4797 · GB/T 4798 · IEC 60270 · IEC 60060 · GB/T 26218.1-2010 · IEC 60815 · GB/T 26218.2-2010
Cited by
- GB/T 42558.1-2023Seismic techniques of electrical equipment in converter station on plateau—Part 1:Directives for seismic test and evaluation
- GB/T 19749.2-2022Coupling capacitors and capacitor dividers - Part 2: DC or AC single-phase coupling capacitor connected between line and ground for power line carrier-frequency (PLC) application
- GB/T 19749.3-2022Coupling capacitors and capacitor dividers - Part 3: AC or DC coupling capacitor for harmonic-filters applications
- GB/T 20840.15-2022Instrument transformers - Part 15: Additional requirements for voltage transformers for DC applications
- GB/T 24841-2018Technical specification for capacitor voltage transformers of 1000kV AC system
How to Download GB/T 19749.1-2016
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 311.1-2012 — Insulation co-ordination -- Part 1: Definitions, principles and rules
GB/T 156-2017 — Standard voltages
GB/T 15601-2013 — Metallic envelope gaskets for pipe flanges
Secure payment via Stripe
Payments accepted
GB/T 19749.1-2016
$465.00