Scope

GB/T 26218.3-2011 is the English-translated version of 污秽条件下使用的高压绝缘子的选择和尺寸确定 第3部分:交流系统用复合绝缘子.

GB/T 26218.3-2011 — This section GB/T 26218 gives the specific characteristics of the insulator substantially in some filthy environment judging guidelines and principles.

This section applies to high voltage AC system under filthy conditions determined by the size and selection of composite insulators. Of this section to CIGRE33.13TF01 [1] [2] as a base, we want in-depth study under filthy conditions insulator Performance Division Research staff can put the file as a useful supplement.

This section does not involve the impact of snow and ice contamination insulator. Although CIGRE [3] which has been studied, but little information available, experience the difference Do not larger.

The purpose of this section is. --- Through on-site contamination degree (SPS) is determined with reference to a unified specific creepage distance (RUSCD); --- Select the appropriate umbrella; --- Unified reference creepage distance (RUSCD) for altitude changes, insulator shape, size, installation location correction.

Found what you need?

Document preview — GB/T 26218.3-2011

National Standard of the People's Republic of China

ICS
29.080.10
Classification
K 48

Issued by: Standardization Administration of China

Contents

  • Preface
  • 1 Scope and purpose
  • 2 Normative references
  • 3 Terms, Definitions and Abbreviations
  • 3.1 Terms and definitions
  • 3.2 Abbreviations
  • 4 Principle
  • 5 Material
  • General Information 5.1 silicone rubber umbrella cover material
  • 5.2 Creepage distance is reduced
  • 6 Site pollution degree determination
  • 7 Reference Unified creepage distance is determined (RUSCD)
  • Generally recommended eight pairs of composite insulators umbrella
  • 9 Umbrella check parameters
  • 9.1 Overview
  • 9.2 Alternating umbrellas and umbrella extend
  • 9.3 Umbrella extended pitch ratio
  • 9.4 Minimum distance between the umbrella
  • 9.5 Creepage distance and spacing
  • 9.6 Umbrella inclination
  • 9.7 Creepage factor
  • 10 Reference Unified creepage distance (RUSCD) amendment
  • 10.1 Fixed Reference Unified creepage distance (RUSCD) Calculation
  • 10.2 Altitude correction Ka
  • 10.3 Insulator diameter correction Kad
  • The minimum creepage distance of 11 finalized
  • 12 Experimental verification
  • Appendix A (informative) of this section with IEC/T S60815-3.2008 technical differences and their causes
  • Annex B (informative) contamination cause deterioration of composite insulators information
  • References

Foreword

GB/T 26218 "under filthy conditions Insulators selection and sizing" is divided into five sections.

--- Part 1. Definitions, information and general principles;

--- Part 2. AC system with porcelain and glass insulators;

--- Part 3. composite insulators for ac systems;

--- Part 4. DC system with porcelain and glass insulators;

--- Part 5. DC system with composite insulators.

This section GB/T 26218 Part 3.

This section drafted in accordance with the rules of GB/T 1.1-2009 and GB/T 20000.2-2009 given.

This section uses redrafted Law Amendment uses IEC/T S60815-3.2008 under "filthy conditions and selection Insulators Sizing Part 3. Polymer insulators for ac systems "(in English).

Given our outdoor insulators under filthy conditions of use are basically silicone rubber composite insulators as the umbrella cover, and epoxy resin, EPDM and other materials as the number of insulators umbrella cover very few and the lack of operating experience, this part of IEC/T S60818-3.2008 name Name and scope have been modified only for dimethyl siloxane based silicone rubber umbrella sets of silicone rubber composite insulators, and deleted IEC/T S60815-3 in relation to non-silicone rubber insulators.

This part of IEC/T S60815-3.2008 technical differences exist compared to the terms of these differences has been involved through its outer margin Vertical single line blank position (|) have been marked, the list given in Appendix A corresponding technical differences and their causes.

This section and IEC/T S60815-3. compared to 2008, reg number changes as follows.

--- 5.2.1 and 5.2.2 of the merger rewritten as 5.2;

--- The suspension of paragraph 10 of Chapter rewrite 10.1, the original title of a strip extended;

--- Number remaining clauses are identical.

Please note that some of the content of this document may involve patents. Release mechanism of the present document does not assume responsibility for the identification of these patents.

This part is proposed by the China Electrical Equipment Industrial Association.

The insulators in part by the National Standardization Technical Committee (SAC/TC80) centralized.

This section drafted by. China Electric Power Research Institute, Xi'an High Voltage Apparatus Research Institute Co., Ltd., State Grid Electric Power Research Institute, National Insulator arrester Quality Supervision and Inspection Center, Tsinghua University, Chongqing University, China Southern Power Grid Company EHV company, State Grid Corporation, China Power Engineering Consulting Group, East China Electric Power Design Institute, China Power Engineering Consulting Group, Central South Electric Power Design Institute, Dalian Insulator Group shares have Ltd., Guangzhou McLean Power Co., Ltd. Xiangfan State Grid composite insulator, Nantong Shenma Power Technology Co., Secretary, Suzhou Cichang Limited.

1 Scope and purpose

This section GB/T 26218 gives the specific characteristics of the insulator substantially in some filthy environment judging guidelines and principles.

This section applies to high voltage AC system under filthy conditions determined by the size and selection of composite insulators.

Of this section to CIGRE33.13TF01 [1] [2] as a base, we want in-depth study under filthy conditions insulator Performance Division Research staff can put the file as a useful supplement.

This section does not involve the impact of snow and ice contamination insulator. Although CIGRE [3] which has been studied, but little information available, experience the difference Do not larger.

The purpose of this section is.

--- Through on-site contamination degree (SPS) is determined with reference to a unified specific creepage distance (RUSCD);

--- Select the appropriate umbrella;

--- Unified reference creepage distance (RUSCD) for altitude changes, insulator shape, size, installation location correction.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.

GB/T 2900.8-2009 Electrotechnical terminology insulator (IEC 60050-471:2007, IDT) GB/T 24622-2009 insulator surface wettability measurement guidelines (IEC/T S62073.2003, IDT) GB/T 26218.1-2010 filthy conditions under high pressure insulator selection and sizing - Part 1. Definitions, information and general Principles (IEC/T S60815-1.2008, MOD)

3 Terms, definitions and abbreviations

3.1 Terms and Definitions

GB/T 2900.8-2009 and GB/T 26218.1-2010 and as defined in the following terms and definitions apply to this document.

3.1.1

Reference Unified creepage distance (RUSCD) referenceunifiedspecificcreepagedistance; RUSCD According to the part size, shape, location, etc. installation unified creepage distance initial value before correction, usually in mm/kV representation.

3.2 Acronyms

The following abbreviations apply to this document.

Creepage factor CF creepagefactor ESDD equivalentsaltdepositdensity ESDD HTM hydrophobicitytransfermaterial hydrophobic material migration

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 14 pages — is available in the English PDF.

Referenced standards

How to Download GB/T 26218.3-2011

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
14 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 26218.3-2011

$195.00