GB/T 24121-2009Textile products - Determination of the remains of broken sewing needle (English PDF)
纺织制品 断针类残留物的检测方法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 24121-2009 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
June 15, 2009
Implementation date
February 1, 2010
Scope
GB/T 24121-2009 is the English-translated version of 纺织制品 断针类残留物的检测方法.
GB/T 24121-2009 is the Chinese standard "Textile products - Determination of the remains of broken sewing needle". Its scope clause reads: This standard specifies the method using a metal detector needle machine needle in the textiles category or ferromagnetic metal residues.
This standard applies to through the production and processing of textile products. Raw materials, semi-finished products and other products may refer to use. Principle 2 Principle of electromagnetic induction, so that the textile products in the category needle or ferromagnetic metal residues occur sensors so as to be detected. Its clauses include testing equipment; sample preparation.
Found what you need?
Document preview — GB/T 24121-2009
National Standard of the People's Republic of China
- ICS
- 59.080.01
- Classification
- W 04
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- 1 Scope
- 3 Testing Equipment
- 3.1 Testing Equipment
- 3.2 Operating Environment
- 3.3 calibration requirements
- 4 Sample Preparation
1 Scope
This standard specifies the method using a metal detector needle machine needle in the textiles category or ferromagnetic metal residues.
This standard applies to through the production and processing of textile products. Raw materials, semi-finished products and other products may refer to use.
Principle 2
Principle of electromagnetic induction, so that the textile products in the category needle or ferromagnetic metal residues occur sensors so as to be detected.
3 Testing Equipment
3.1 Testing Equipment
According to detect the nature of the subject and the type of textile products related standards and form selection with appropriate sensitivity detection equipment.
3.1.1 transport metal needle machine
used textiles production and processing enterprises, textile products detected in needles left behind iron, iron and other ferromagnetic
Substances can also be used to detect the detection mechanism for textile products in categories needle or ferromagnetic metal residues. Common detection sensitivity (standard iron
Ball test card, also known as the standard needle test block) have. 0.8mm, 1.0mm, 1.2mm, 1.5mm, 2.0mm, 2.5mm and 3.0mm.
3.1.2 Desktop metal detector
for small pieces, thin pieces, bedding and other textile products in categories needle or ferromagnetic metal residues detection
Measurement. Common detection sensitivity (standard iron ball test card, also known as the standard needle test block) have. 1.0mm, 1.2mm, 1.5mm and
2.0mm.
3.1.3 hand-held metal detector
for the detection of small pieces, thin pieces of broken needles and other textile products in class or ferromagnetic metal residues may also be
Other auxiliary needle machine accurate detection of defective needle class or ferromagnetic metal residues. Common detection sensitivity (standard iron ball test card,
Also known as the standard needle test block) have. 0.8mm, 1.0mm and 1.2mm.
3.2 Operating Environment
3.2.1
Detection equipment should stay away from magnetic sources (such as large transformers, high voltage power lines, electric fans, motors, etc.) and local oscillator.
3.2.2
testing equipment around 1m or less without any ferromagnetic metal objects.
3.3 calibration requirements
3.3.1
each calibration, should be turned off, wipe testing equipment.
3.3.2
testing equipment to normal operation after startup, calibration.
3.3.3
testing equipment officially detection, calibration should be performed for the first time every time.
3.3.4
Detection equipment should be calibrated at least once a continuous work within 2h.
3.3.5
concludes, response testing equipment for the last calibration.
3.3.6
shall designate a person calibration and testing, staff shall not carry watches, cell phones, keys, metal buckle with a magnetic leader belts
Items.
3.3.7
Calibration with iron ball test card selected according to the detection sensitivity of the device or intended size thereof.
3.3.8
Calibration transport metal needle machine using 9 test method (see Appendix A) for calibration. Desktop can refer to the use of metal detectors.
3.3.9
hand-held metal detector after each boot, and issued a tweet appeared luminescent signal, the power to meet the requirements, or need to replace the
Source; standard iron ball test card placed in hand-held metal detector square meter surface of the effective height, can trigger the alarm sound, then meet
Testing requirements; otherwise requires inspection, repair and testing equipment, iron ball until the standard tests until the alarm card declined.
4 Sample Preparation
Samples were organized into easy to shape detection. If the height of the folded samples above the detection equipment gantry height, width greater than the effective
GB/T 24218.15-2018 | GB/T 24218.17-2017 | GB/T 24218.16-2017 | GB/T 24118-2009 | GB/T 24117-2009 | GB/T 24115-2009 | […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Similar standards
How to Download GB/T 24121-2009
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 10004-2026 — Plastic/Plastic laminated films and pouches for packaging
GB/T 10007-2026 — Rigid cellular plastics - Determination of shear properties
Secure payment via Stripe
Payments accepted
GB/T 24121-2009
$115.00