GB/T 19812.3-2017Plastic equipment for water saving irrigation—Part 3: Drip pipe and drip tape inlaid with emitters inside (English PDF)
塑料节水灌溉器材 第3部分:内镶式滴灌管及滴灌带
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 19812.3-2017 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
November 1, 2017
Implementation date
May 1, 2018
Scope
GB/T 19812.3-2017 is the English-translated version of 塑料节水灌溉器材 第3部分:内镶式滴灌管及滴灌带.
GB/T 19812.3-2017 is Part 3 of the Chinese national series on plastic water-saving irrigation equipment and covers drip pipe and drip tape with emitters inlaid inside.
It applies to non-pressure-compensating pipe and tape made mainly from polyolefin, carrying water at no more than 45 °C. The standard sets out terms, marking, materials and requirements such as flow uniformity, the relation between flow and inlet pressure, resistance to sediment clogging, pressure resistance, burst pressure, tensile performance, artificial ageing and carbon black content.
It also gives the sample conditioning, the test methods, the inspection rules and the packaging, transport and storage. Manufacturers and test laboratories use it.
It replaces GB/T 19812.3-2008, was issued on 1 November 2017 and has applied since 1 May 2018.
Found what you need?
Document preview — GB/T 19812.3-2017
National Standard of the People's Republic of China
- ICS
- 23.040.20
- Classification
- G 33
- Replacing
- GB/T 19812.3-2008
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
Foreword
GB/T 19812 "plastic water-saving irrigation equipment" is divided into five parts.
--- Part 1. Single-wing labyrinth drip tape;
--- Part 2. Pressure compensated dripper and drip irrigation pipe;
--- Part 3. Inlaid drip irrigation and drip tape;
--- Part 4. Polyethylene (PE) branch pipe;
--- Part 5. Buried drip pipe.
This section GB/T 19812 Part 3.
This section drafted in accordance with GB/T 1.1-2009 given rules.
This Part replaces GB/T 19812.3-2008 "plastic water-saving irrigation equipment inlaid drip irrigation pipe, with" and GB/T 19812.3-2008 compared to the main technical changes other than editorial changes are as follows.
--- The standard name was changed to "plastic water-saving irrigation equipment Part 3. Inlaid drip irrigation and drip tape";
--- Removed the "paragraph" in the last paragraph "This section does not apply to the use of buried irrigation pipe, with" (see Chapter 1, 2008 edition 1 chapter);
--- Normative references added GB/T 2918-1998, GB/T 8804.3-2003, GB/T 16422.2-2014, GB/T 19278-2003, GB/T 19466.6-2009, SL571-2013 (see Chapter 2);
--- Removed the term "flow index", adding "rated working pressure" "nominal wall thickness" "nominal diameter" of the definition (see Chapter 3, 2008 edition Chapter 3);
--- "Marking" chapter added "wall thickness" of the marking requirements "Specifications. Pipe diameter (mm) × nominal wall thickness (mm) × Drip hole spacing (mm) "(see Chapter 4, 2008 Edition, Chapter 5);
--- "Material" chapter, an increase of "manufacture of drip irrigation pipe, drip irrigation tape used should be polyethylene" "should not use medical waste and have Recycled materials from toxic and hazardous chemical packaging "" Made according to this section Polyethylene drip irrigation tubes or polyethylene drip tapes Used raw materials can be added to recover from the field according to this part of the production of polyethylene drip tape made of recycled material, the performance should be Fu For the requirements of this part, see Appendix A "and other requirements (see Chapter 5, 2008 edition Chapter 6);
--- Deleted two kinds of pressure rating of "250kPa" and "320kPa" (see 6.3.1, 2008 edition 7.2.1) in the specification of drip irrigation pipe;
--- Remove the "drip irrigation with nominal wall thickness and its limit deviation" requirements "0.50mm" "0.60mm" two specifications (see 6.3.2.2, 2008 edition 7.2.2.2);
--- Modify "C" value and "Cv" value in "Flow Uniformity" requirement, "C" is changed to "Average flow q relative to rated flow qn (C) should be within ± 7%. "" Cv "should be amended to read" not to exceed 7% "(see 6.4, 2008 version 7.3);
--- Modify "the relationship between flow and inlet pressure" in the "Rq", revised to "the average flow curve of the flow rate relative to The deviation (Rq value) of the flow rate obtained from the plant curve should be within ± 7%. "(See 6.5, 2008 edition 7.4);
--- Increase the "anti-sediment blocking performance requirements" (see 6.6);
--- Modify the "pressure resistance" at 23 °C and change to "non-reusing drip tape should be able to withstand 1.5 times the rated working pressure;" "Reusable Drip pipe, drip tape should be able to withstand 2 times the rated working pressure "" Flow rate deviation should be within ± 7%. " (See 6.7.1, 2008 edition 7.5.1);
--- Modify the "water pressure at 45 °C", the test temperature is modified to "(45 ± 2) °C"; the maintenance time is changed to "and maintain 1h"; flow The amount of deviation is revised to read "Flow rate deviation should be within ± 7%" (see 7.6.2, 2008 version 7.5.2);
--- Increased non-multiplex drip tape "burst pressure" requirements and test methods (see 6.8,8.8);
--- Modify the "pull-pull performance" in the load, revised to "should be able to withstand the required load" (see 6.9, 2008 version 7.6);
--- Increasing the reuse of drip irrigation, drip irrigation with "artificial aging performance" requirements (see 6.10);
--- Modify the "carbon black content" index value, revised to "(2.25 ± 0.50)%" (see 6.1.8.2008 edition 7.9);
--- Increase the sample conditioning requirements, "Unless otherwise specified, the sample at an ambient temperature of (23 ± 2) °C under the conditions adjusted to Less 24h. "(See 7.2);
--- Modify the "flow and the relationship between the inlet pressure" test method (see 8.5, 2008 8.5);
--- Increase "anti-sediment clogging performance" test method (see 8.6);
--- pull-resistant performance test method to increase Table 7, the test load is loaded by the nominal wall thickness of the product were classified (See 8.9);
--- Increasing the "artificial aging performance" test method (see 8.10);
--- Modify the "batch" program, revised to "each batch of 5,000 volumes"; seven days production was revised to "less than 5,000 volumes" (see 9.1, 2008 Edition 9.1);
--- Added "batch number N and sample size n" in Sampling Plan (see 9.2.2);
--- Modify the "type test" period, revised to "two years" (see 9.3, 2008 version 9.3);
--- Increasing the "type test" decision rules (see 9.4.2);
--- Added an informative appendix "Polyethylene recycling materials performance" (see Appendix A).
1 Scope
This section GB/T 19812 specifies the terms and definitions, markings, materials, requirements, samples and tests of inlaid drip irrigation and drip irrigation tape Conditions, test methods, inspection rules and packaging signs, packaging, transportation, storage.
This section applies to the main material using polyolefin as the main raw material inlay non-pressure compensation drip irrigation pipe and drip tape (hereinafter referred to as "drops Irrigation "or" drip tape "), the transmission medium temperature does not exceed 45 °C.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version applies to this document. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 2828.1-2012 Sampling procedures for inspection - Part 1 - Batch-by-lot inspection by acceptance quality limit (AQL) plan
GB/T 2918-1998 plastic sample conditioning and testing of the standard environment
GB/T 8804.3-2003 Determination of tensile properties of thermoplastic pipe - Part 3 Polyolefin pipes
Plastics piping systems - Determination of dimensions of plastic parts
GB/T 13021-1991 Polyethylene pipe and fittings - Determination of carbon black content (TG method)
GB/T 15819-2006 Irrigation polyethylene (PE) pipe by the plug-in pipe caused by environmental stress cracking resistance test side Law and technical requirements
GB/T 16422.2-2014 Plastics - Laboratory exposure test methods - Part 2: Xenon arc lamps
Technical specifications and test methods for drippers and drip irrigation pipes for agricultural irrigation equipment GB/T 17187-2009
GB/T 18251-2000 Polyolefin pipes, fittings and mixed materials Determination of pigment or carbon black dispersion
Thermoplastics pipes, fittings and valves - Generic terminology and their definitions GB/T 19278-2003
GB/T 19466.6-2009 plastic differential scanning calorimetry (DSC) Part 6: Oxidation induction time (isothermal OIT) and oxygen Induction of temperature (dynamic OIT) determination
Standard Test Method for Hydraulic Basic Parameters of Water Saving Irrigation Equipment
3 Terms and definitions
GB/T 17187-2009, GB/T 19278-2003 defined and the following terms and definitions apply to this document.
3.1 Drip pipe inlaid with emitters inside
Drip at a certain distance or continuous set in the tube, and in the drip processing holes, drip form of water tube.
3.2 Drip tape inlaid with emitters inside
Drip at a certain distance or continuous set in the band, and in the drip processing holes, dripping water in the form of belt.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 2828.1-2012Sampling procedures for inspection by attributes - Part 1: Sampling schemes indexed by acceptance quality limit (AQL) for lot-by-lot inspection
- GB/T 2918-1998Plastics -- Standard atmospheres for conditioning and testing
- GB/T 8804.3-2003Thermoplastic pipes -- Determination of tensile properties -- Part 3: Polyolefin pipes
- GB/T 13021-1991Polyolefin pipes and fittings - Determination of carbon black content - Test method of calcination and pyrolysis
- GB/T 15819-2006Polyethylene (PE) pipes for irrigation laterals -- Test method and specification of susceptibility to environmental stress cracking induced by insert-type fittings
- GB/T 16422.2-2014Plastics - Methods of exposure to laboratory light sources - Part 2: Xenon-arc lamps
Similar standards
Editions of GB/T 19812.3
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB/T 19812.3-2017 | Plastic equipment for water saving irrigation—Part 3: Drip pipe and drip tape inlaid with emitters inside | current edition | Current |
| GB/T 19812.3-2008 | Plastic equipment for water saving irrigation—Part 3: Drip pipe and drip tape inlaid with emitters inside | previous edition | Superseded |
This page sells the current edition, GB/T 19812.3-2017. Earlier editions are listed for reference only.
How to Download GB/T 19812.3-2017
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 15819-2006 — Polyethylene (PE) pipes for irrigation laterals -- Test method and specification of susceptibility to environmental stress cracking induced by insert-type fittings
GB/T 17187-2009 — Agricultural irrigation equipment -- Emitters and emitting pipe -- Specification and test methods
GB/T 19466.6-2009 — Plastics -- Differential scanning calorimetry (DSC) -- Part 6: Determination of oxidation induction time (isothermal OIT) and oxidation induction temperature (dynamic OIT)
Secure payment via Stripe