GB/T 19258.1-2022Ultraviolet radiation sources for germicidal purpose—Part 1: Low pressure mercury vapor discharge lamp (English PDF)
杀菌用紫外辐射源 第1部分:低气压汞蒸气放电灯
This is a limited preview
Buy now to download the full PDF (38 pages)
Need quotation for your management?
Get a formal quotation for GB/T 19258.1-2022 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
October 14, 2022
Implementation date
May 1, 2023
Scope
GB/T 19258.1-2022 is the English-translated version of 杀菌用紫外辐射源 第1部分:低气压汞蒸气放电灯.
GB/T 19258.1-2022 is Part 1 of the Chinese standard on ultraviolet radiation sources for germicidal purposes, the low pressure mercury vapour discharge lamp.
It specifies the product classification, marking and model naming, the technical requirements, the test methods, the inspection rules and the rules for marking, packaging, storage and transport.
It applies to double-capped, single-capped and self-ballasted lamps made of quartz or other ultraviolet-transmitting glass, with or without ozone, whose ultraviolet radiation peaks at 253.7 nm and whose nominal power is below 58 W, and it excludes cold cathode ultraviolet lamps.
Five annexes give the test methods for ultraviolet radiation flux and electrical parameters, for ultraviolet radiation luminance, for ozone output by the static and the dynamic method, and for lamp life.
It replaces GB/T 19258-2012, was issued on 14 October 2022 and has applied since 1 May 2023.
Found what you need?
Document preview — GB/T 19258.1-2022
National Standard of the People's Republic of China
- ICS
- 29.140.30
- Classification
- K 71
- Replacing
- GB/T 19258-2012
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword3
- Introduction5
- 1 Scope6
- 2 Normative references6
- 3 Terms and definitions7
- 4 Product classification, marking and model naming10
- 5 Technical requirements10
- 6 Test methods14
- 7 Inspection rules15
- 8 Marking, packaging, storage and transportation16
- Annex A (normative) Test methods for ultraviolet radiation flux and electrical parameters19
- Annex B (normative) Measurement method of ultraviolet radiation luminance23
- Annex C (normative) Test method for ozone output (static method)29
- Annex D (informative) Test method for ozone output (dynamic method)33
- Annex E (normative) Life test method36
- Bibliography38
1 Scope
This document specifies the product classification, technical requirements, test methods, inspection rules and marking, packaging, transportation and storage of low-pressure mercury vapor discharge ultraviolet germicidal lamps (hereinafter referred to as "lamps").
This document applies to double-capped, single-capped or self-ballasted lamps made of quartz glass or other ultraviolet-transmitting glass, with or without ozone and with an ultraviolet radiation peak wavelength of 253.7 nm.
This document applies to lamps with a nominal power of less than 58 W, excluding cold cathode ultraviolet lamps.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
GB/T 1406.1 Types and dimensions of lamp caps - Part 1: Screw caps
GB/T 1406.2 Types and dimensions of lamp caps - Part 2: Pin lamp caps
GB/T 1406.5 Types and dimensions of lamp caps - Part 5: Bayonet caps
GB/T 2797 Technical specification for lamp caps
GB/T 2828.1 Sampling procedures for inspection by attributes - Part 1: Sampling schemes indexed by acceptance quality limit (AQL) for lot-by-lot inspection
GB/T 2829 Sampling procedures and tables for periodic inspection by attributes (apply to inspection of process stability)
GB/T 2900.65-2004 Electrotechnical terminology - Lighting
GB/T 10682 Double-capped fluorescent lamps - Performance specifications
GB 16843 Single-capped fluorescent lamps - Safety specifications
GB 16844 Self-ballasted lamps for general lighting services - Safety requirements
GB/T 17262 Single-capped fluorescent lamps - Performance specification
GB/T 17263 Self-ballasted lamps for general lighting service - Performance requirements
GB 18774 Double-capped fluorescent lamps - Safety specifications
JJG 879-2015 Ultraviolet radiometers
HJ 590 Ambient air - Determination of ozone - Ultraviolet photometric method
3 Terms and definitions
For the purpose of this document, the terms and definitions defined in GB/T 2900.65-2004 and the following apply.
3.1 Ultraviolet germicidal lamp
A low-pressure mercury vapor discharge lamp made of quartz glass or other ultraviolet-transmitting glass, producing ultraviolet radiation mainly with a wavelength of 253.7 nm by discharge.
3.2 Ozone concentration
The mass of ozone produced per unit volume when the lamp is ignited under specified conditions.
3.3 Ozone output efficacy
The ratio of the amount of ozone produced per unit time to the power consumed by the lamp when the lamp is ignited under specified conditions.
3.4 Nominal value
The approximate value used to name or identify the lamp.
3.5 Rated value
The numerical value of a certain characteristic of the lamp under specified conditions.
3.6 Initial readings
The starting characteristics of the lamp measured before aging and the ultraviolet radiation, electrical characteristics and ozone characteristics measured after aging for 100 h.
4 Product classification, marking and model naming
4.1 Classification and marking
According to the shape, lamps can be divided into three categories: double-capped lamps (indicated by "S"), single-capped lamps (indicated by "D") and self-ballasted lamps (indicated by "Z"); according to whether it contains ozone, it can be divided into two types: ozone (indicated by "Y") and ozone-free (indicated by "W").
4.2 Model naming method
The model naming method of lamps is as follows:
Example 1: ZW15S26W indicates a 15 W double-capped ozone-free ultraviolet germicidal lamp with a tube diameter of 26 mm.
5 Technical requirements
5.1 General requirements
The design, structure and performance of lamps shall ensure reliable performance in normal use and not cause danger to users and the surrounding environment. Generally, the qualification is checked by conducting all the specified tests.
5.3 Glass tube
The glass tube of lamps shall be transparent and clean and shall not have defects that affect the transmission of ultraviolet rays.
5.4 Lamp holder
The finished lamp shall be equipped with a lamp cap that meets the corresponding light source performance standards.
The types and dimensions of pin, screw and bayonet lamp caps shall comply with the provisions of GB/T 1406.2, GB/T 1406.1 and GB/T 1406.5, respectively. Lamp caps of other specifications shall comply with the provisions of GB/T 2797.
5.5 Anti-ultraviolet radiation
The insulating materials used for lamp caps and lamp housings shall be resistant to ultraviolet radiation, anti-ultraviolet aging and embrittlement. After completing the test in 6.9, the sample shall not have any changes that weaken its safety, the anti-electric shock performance of the insulating material shall not be reduced, the lamp cap and the lamp cap pins shall not be loose, and the insulating material shall not be cracked, bulged or shrunken.
5.6 Lamp dimensions
The dimensions of double-capped lamps, single-capped lamps and self-ballasted lamps shall comply with the provisions of the corresponding model lamps in GB/T 10682, GB/T 17262 and GB/T 17263, respectively.
5.7 Starting characteristics
Lamps shall have good starting characteristics, and the starting characteristics of double-capped lamps, single-capped lamps and self-ballasted lamps shall comply with the provisions of the corresponding power lamps in GB/T 10682, GB/T 17262 and GB/T 17263, respectively.
5.8 Initial electrical parameters
The initial voltage value of double-capped lamps and single-capped lamps shall comply with the provisions of the corresponding power lamps in GB/T 10682 and GB/T 17262, respectively.
5.9 Ultraviolet radiation efficiency
The initial value of the ultraviolet radiation efficiency of double-capped lamps, single-capped lamps and self-ballasted lamps shall not be lower than the value specified in Table 1.
5.10 Ultraviolet radiation flux
The ultraviolet radiation flux can be nominally stated by the manufacturer and the seller, and the actual measured value shall not be less than 90 % of the nominal value.
5.11 Ultraviolet radiation luminance
The initial value of the ultraviolet radiation luminance of double-capped lamps and single-capped lamps shall not be less than 93 % of the values specified in Table 2 and Table 3, respectively.
5.12 Ozone concentration/ozone output efficacy
Ozone-free lamps are evaluated by ozone concentration, and ozone lamps are evaluated by initial ozone output efficacy.
The ozone concentration of ozone-free lamps is expressed as the average mass concentration per unit time, and the average maximum allowable concentration for 1 h is 0.1 mg/m³.
6 Test methods
6.1 Glass tube
Inspect by visual method.
6.2 Lamp cap
Inspect by corresponding gauge.
6.3 Anti-ultraviolet radiation
For the anti-ultraviolet aging of insulating materials, after testing according to 6.9, use visual method and special gauges for inspection.
6.4 Lamp dimensions
Use general measuring tools or special gauges with an accuracy of not less than 0.05 mm for inspection.
6.5 Starting characteristics and initial electrical parameters
Single-capped lamps are tested according to the method specified in GB/T 17262.
Self-ballasted lamps are tested according to the method specified in GB/T 17263.
Double-capped lamps are tested according to the method specified in GB/T 10682.
6.6 Ultraviolet radiation efficiency, ultraviolet radiation flux
Test according to the method specified in Annex A.
6.7 Ultraviolet radiation luminance
Test according to the method specified in Annex B.
6.8 Ozone concentration/ozone output efficacy
Test according to the method specified in Annex C.
For ultraviolet lamps with ozone output used in dynamic airflow environments, refer to Annex D for testing.
7 Inspection rules
7.1 Inspection classification
Inspection is divided into factory-exit inspection and type inspection.
7.2 Factory-exit inspection
The samples for factory-exit inspection shall be uniformly taken from the same type of lamps produced daily (from each batch). Factory-exit inspection shall be carried out in accordance with GB/T 2828.1, and its inspection items, sampling plan, inspection level and acceptance quality level shall comply with the provisions of Table 4.
7.3 Type inspection
Type inspection shall be carried out at least once a year. The samples for type inspection shall be uniformly taken from the lamps that have passed the factory-exit inspection.
8 Marking, packaging, storage and transportation
8.1 Marking
The marking content on lamps shall comply with the requirements of Table 6 and shall be clear and firm.
8.2 Packaging
The minimum sales package shall contain a product certificate. If the minimum sales package contains multiple lamps, the number of lamps shall be indicated.
8.3 Storage
Lamps shall be stored in a ventilated room with a relative humidity not exceeding 85 %, and there shall be no corrosive gases in the air.
8.4 Transportation
Lamps shall be protected from rain, snow and strong mechanical vibration during transportation. […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 38 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 1406.1Types and dimensions of lamp caps - Part 1: Screw caps
- GB/T 1406.2Types and dimentions of lamp caps - Part 2: Pin lamp caps
- GB/T 1406.5Types and dimensions of lamp caps - Part 5: Bayonet caps
- GB/T 2828.1Sampling procedures for inspection by attributes - Part 1: Sampling schemes indexed by acceptance quality limit (AQL) for lot-by-lot inspection
- GB/T 2829Sampling procedures and tables for periodic inspection by attributes
- GB/T 2900.65-2004Electrotechnical terminology - Lighting
GB/T 2797 · GB 16843 · GB 16844 · GB 18774
Cited by
- GB/T 47306-2026Design specification for engineering measures for epidemic prevention on livestock and poultry farms
- GB/T 21866-2025Test method for antiviral activity and antimicrobial of paints film
- GB/T 45515-2025Quality grading of consumer products - Lighting products
- GB/T 46321-2025Assessment of fungal growth resistance of adhesive
- GB/T 13477.25-2024Test method for building sealants - Part 25: Determination of resistance to mold
- GB/T 44755-2024Low pressure high output ultraviolet (UV) lamp
Similar standards
Editions of GB/T 19258.1
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB/T 19258.1-2022 | Ultraviolet radiation sources for germicidal purpose—Part 1: Low pressure mercury vapor discharge lamp | current edition | Current |
| GB/T 19258-2012 | Ultraviolet radiation sources for germicidal purpose—Part 1: Low pressure mercury vapor discharge lamp | previous edition | Superseded |
This page sells the current edition, GB/T 19258.1-2022. Earlier editions are listed for reference only.
How to Download GB/T 19258.1-2022
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10682-2010 — Double-capped fluorescent lamps -- Performance specifications
GB/T 1406.1-2008 — Types and dimensions of lamp caps - Part 1: Screw caps
GB/T 1406.1-2026 — Types and dimensions of lamp caps - Part 1: Screw caps
Secure payment via Stripe
Payments accepted
GB/T 19258.1-2022
$420.00