JJG 879-2015Ultraviolet Radiometers (English PDF)
This is a limited preview
Buy now to download the full PDF (19 pages)
Need quotation for your management?
Get a formal quotation for JJG 879-2015 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China Adm
Level / Type
National · Mandatory
Issue date
December 7, 2015
Implementation date
June 7, 2016
Scope
JJG 879-2015 (Ultraviolet Radiometers) is available as an English-translated PDF.
JJG 879-2015 is the Chinese standard "Ultraviolet Radiometers".
Its scope clause reads: This Regulation applies to initial verification, subsequent verification and in-use inspection for standard-level, level-1 and level-2 ultraviolet radiometers that comply with the division of ultraviolet radiation UV-A, UV-B, UV-C, UV-A1, UV-365, UV-310, UV-254 bands.
Its clauses include overview; metrology performance requirements; general technical requirements; measuring instrument control. It was issued by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China Adm on 2015-12-07 and took effect on 2016-06-07.
Found what you need?
Document preview — JJG 879-2015
National Standard of the People's Republic of China
Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China Adm
Contents
- Introduction...5
- 1 Scope...6
- 2 Overview...6
- 3 Metrology performance requirements...7
- 3.1 Spectral response and band division...7
- 3.2 Zero-value error (full scale FS)...7
- 3.3 Long-wave response error...7
- 3.4 Cosine characteristic (directional response) error...8
- 3.5 Nonlinear error...8
- 3.6 Shifting error...8
- 3.7 Fatigue error...9
- 3.8 Relative indication error...9
- 4 General technical requirements...9
- 4.1 Appearance...9
- 4.2 Optical attenuator...9
- 4.3 Spectral response range...9
- 5 Measuring instrument control...10
- 5.1 Verification conditions...10
- 5.2 Verification items...11
- 5.3 Verification methods...12
- 5.4 Processing of verification results...19
- 5.5 Verification cycle...19
1 Scope
This Regulation applies to initial verification, subsequent verification and in-use inspection for standard-level, level-1 and level-2 ultraviolet radiometers that comply with the division of ultraviolet radiation UV-A, UV-B, UV-C, UV-A1, UV-365, UV-310,
UV-254 bands.
2 Overview
The International Commission on Illumination (CIE) divides ultraviolet radiation into three bands. UV-A (315nm~400nm), UV-B (280nm~315nm) and UV-C (100nm~280nm). Since ultraviolet radiation of 100nm~200nm is strongly absorbed in the air, for the UV-C band, this Regulation only considers the wavelength range of
200nm~280nm.
3 Metrology performance requirements
3.1 Spectral response and band division
3.2 Zero-value error (full scale FS)
The zero-value error (FS) of ultraviolet radiometers shall not exceed the requirements of Table 1.
3.3 Long-wave response error
The long-wave response error of the ultraviolet radiometer shall not exceed the requirements of Table 2.
3.4 Cosine characteristic (directional response) error
The cosine characteristics (directional response) of the ultraviolet radiometer shall not exceed the requirements of Table 3.
4 General technical requirements
4.1 Appearance
4.1.1 The nameplate of the ultraviolet radiometer shall be marked with the trademark, model, product number, date of manufacture and CMC logo. The power supply used and the safety protection during operation shall be given accurate and eye-catching descriptive markings.
4.2 Optical attenuator
If the ultraviolet radiometer is equipped with a light attenuator, the light attenuator shall be intact and the attenuation rate shall be marked.
4.3 Spectral response range
The spectral response range of the ultraviolet radiometer shall comply with the provisions of 3.1.
5 Measuring instrument control
Measuring instrument control includes initial verification, subsequent verification and in-use inspection.
5.1 Verification conditions
5.1.1 Equipment for verification
5.1.1.3 Measurement device for comparison of UV radiation illuminance
The reference schematic diagram of the structure of the ultraviolet radiation illumination comparison measurement device is shown in Figure 2
5.1.2 Environmental conditions
Indoor temperature 23°C±5°C; relative humidity <=70%.
Shading measures shall be taken indoors to prevent interference from the sun, incandescent light sources and other light sources.
5.2 Verification items
See Table 8 for the verification items.
5.3.5 Shifting error
The test is performed between two different ranges of the Ultraviolet radiometer.
Ultraviolet radiometers with a single range do not perform this test.
5.3.6 Fatigue error
Install the detector and UV radiation source of the Ultraviolet radiometer on the measuring device (Figure 2). Adjust the light path according to the requirements for calibrating the Ultraviolet radiometer. Then cover the detector so that it is not exposed for 24 h.
5.5 Verification cycle
The verification cycle of UV radiation illuminance meter generally does not exceed one year.
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 19 pages — is available in the English PDF.
Referenced standards
Cited by
- GB/T 45183-2025Plastics - Instrumental determination of radiant exposure in weathering tests - General guidance and basic test method
- GB/T 19258.2-2023Ultraviolet radiation sources for germicidal purpose—Part 2: Cold cathode low pressure mercury vapor discharge lamp
- GB/T 19258.1-2022Ultraviolet radiation sources for germicidal purpose—Part 1: Low pressure mercury vapor discharge lamp
How to Download JJG 879-2015
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJG 1201-2024 — Digital Tyre Pressure Gauges
JJG 1202-2024 — Long Distance Transmissible Pressure Gauges
JJG 746-2024 — Ultrasonic Flaw Detectors
Secure payment via Stripe
Payments accepted
JJG 879-2015
$615.00