Scope
GB/T 19258.2-2023 is the English-translated version of 杀菌用紫外辐射源 第2部分:冷阴极低气压汞蒸气放电灯.
GB/T 19258.2-2023 is Part 2 of the Chinese series on ultraviolet radiation sources for germicidal use and deals with the cold cathode low pressure mercury vapour discharge lamp.
It sets the product classification and model designation, the technical requirements, the test methods, the inspection rules and the rules for marking, packaging, storage and transport.
It applies to ozone and ozone-free lamps made of quartz glass or other ultraviolet-transmitting glass whose radiation peaks at 253.7 nm, in double-ended, single-ended, self-ballasted and wire-terminal forms.
Six normative annexes give the measurement of lamp and electrical parameters, of starting characteristics, of ultraviolet radiation flux and irradiance, the static method for ozone production and the life test.
It cites GB/T 2900.65, GB/T 19258.1-2022, JJG 879-2015 and HJ 590-2010. It replaces GB/T 28795-2012, was issued on 7 September 2023 and has applied since 1 April 2024.
Found what you need?
Document preview — GB/T 19258.2-2023
National Standard of the People's Republic of China
- ICS
- 29.140.30
- Classification
- K 71
- Replacing
- GB/T 28795-2012
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Preface
- Introduction
- 1 Scope
- 2 Normative reference documents
- 3 Terms and Definitions
- 4 Product classification, marking and model designation
- 5 Technical requirements
- 6 Test method
- 7 Inspection Rules
- 8 Logo, instructions, packaging, certificate, storage and transportation
- Appendix A (normative) Measurement methods of lamp and electrical parameters
- Appendix B (normative) Measurement method of lamp starting characteristics
- Appendix C (normative) Test method for ultraviolet radiation flux
- Appendix D (normative) Measurement method of ultraviolet radiation illuminance
- Appendix E (normative) Test method for ozone production (static method)
- Appendix F (normative) Life test method
- Reference
Foreword
This document complies with the provisions of GB/T 1.1-2020 "Standardization Work Guidelines Part 1: Structure and Drafting Rules of Standardization Documents" Drafting.
This document is Part 2 of GB/T 19258 "Ultraviolet radiation sources for sterilization". GB/T 19258 has released the following parts.
---Part 1: Low pressure mercury vapor discharge lamp;
---Part 2: Cold cathode low pressure mercury vapor discharge lamps.
This document replaces GB/T 28795-2012 "Cold Cathode Ultraviolet Germicidal Lamps". Compared with GB/T 28795-2012, except for structural adjustments in addition to editorial changes, the main technical changes are as follows.
---Added the definition of UV radiation illumination maintenance rate (see 3.18);
---The shape of the lamp has been changed, and the lead or lead terminal type cold cathode low-pressure mercury vapor discharge, which is more popular on the market, has been added Ultraviolet germicidal lamps, and stipulates its relevant technical requirements (see 4.1, Chapter 5, GB/T 28795-2012 4.1, 4.3, Chapter Chapter 5);
---Changed the rules for writing lamp models (see 4.2, 4.2 of GB/T 28795-2012);
---Added and modified the starting characteristics requirements and test methods of lamps (see 5.3 and Appendix B);
---Changed the regulations on the measurement distance of ultraviolet radiation illumination (see 6.6, 6.6 of GB/T 28795-2012);
---Changed the regulations on marking and packaging (see Chapter 8, Chapter 8 of GB/T 28795-2012);
---Changed the measurement method of lamp electrical parameters (see Appendix A, Appendix C of GB/T 28795-2012);
---An ultraviolet distributed radiometer is added, and the irradiance integration method is used to measure the ultraviolet radiation flux of the ultraviolet germicidal lamp under test (see attachment Record C);
--- Added provisions for the cosine characteristics and nonlinear error requirements of UV probes, and changed the test conditions for measuring UV radiation illumination (see Appendix D, Appendix A of GB/T 28795-2012);
---Changed the test method for ozone production (see Appendix E, Appendix F of GB/T 28795-2012);
---Changed the test method for lamp life (see Appendix F, Appendix E of GB/T 28795-2012).
Introduction
After pathogenic microorganisms absorb ultraviolet radiation energy with wavelengths between 200nm and 280nm, their genetic material (nucleic acid) undergoes mutations, leading to the disinfection method that causes cells to no longer divide and reproduce and achieve the purpose of inactivating pathogenic microorganisms is called ultraviolet disinfection. UV radiation source as UV killer the core component of sterilization products is used to achieve the purpose of sterilization and disinfection. GB/T 19258 "Ultraviolet radiation source for sterilization" aims to standardize the The safety requirements and performance requirements of ultraviolet radiation sources are planned to be composed of 5 parts.
---Part 1: Low-pressure mercury vapor discharge lamps. The purpose is to standardize the production of low-pressure mercury vapor discharge hot cathode ultraviolet germicidal lamps. Product classification, technical requirements, test methods, inspection rules and markings, packaging, transportation and storage.
---Part 2: Cold cathode low pressure mercury vapor discharge lamps. The purpose is to standardize low-pressure mercury vapor discharge cold cathode ultraviolet sterilization Product classification, technical requirements, test methods, inspection rules and markings, packaging, transportation and storage of lamps.
---Part 3: UV excimer lamp. The purpose is to standardize the product classification and technology of 222nm ultraviolet KrCl excimer lamps Requirements, test methods, inspection rules and markings, packaging, transportation and storage.
---Part 4: UV germicidal lamp based on photocatalysis. The purpose is to standardize products that utilize ultraviolet radiation sources for photocatalytic sterilization Classification, technical requirements, test methods, inspection rules and markings, packaging, transportation and storage.
---Part 5: UV LED radiation source for sterilization. The purpose is to standardize the product classification and technology of UV LED radiation sources for sterilization Requirements, test methods, inspection rules and markings, packaging, transportation and storage.
1 Scope
This document specifies the ultraviolet radiation source cold cathode low pressure mercury vapor discharge lamp for sterilization, that is, cold cathode ultraviolet germicidal lamp (hereinafter referred to as "Lamp") product classification, technical requirements, test methods, inspection rules and markings, packaging, transportation and storage.
This document applies to ozone or ozone-free products produced using quartz glass or other ultraviolet-transparent glass. The peak wavelength of ultraviolet radiation is 253.7nm double-ended, single-ended, self-ballasted, wire or wire terminal lamps.
2 Normative reference documents
The contents of the following documents constitute essential provisions of this document through normative references in the text. Among them, the dated quotations for undated referenced documents, only the version corresponding to that date applies to this document; for undated referenced documents, the latest version (including all amendments) applies to this document.
GB/T 2828.1-2012 Enumeration sampling inspection procedures Part 1: Batch-by-batch inspection sampling retrieved by acceptance quality limit (AQL) plan
GB/T 2829-2002 Periodic inspection counting sampling procedures and tables (applicable to inspection of process stability)
GB/T 2900.65 Electrical terminology lighting
GB 16843 Safety requirements for single-ended fluorescent lamps
GB 16844 Safety requirements for self-ballasted lamps for general lighting
GB/T 17263 Performance requirements for self-ballasted fluorescent lamps for general lighting
GB 18774 Safety requirements for double-ended fluorescent lamps
GB/T 19149 General requirements and requirements for tubular discharge lamp transformers (neon lamp transformers) with no-load output voltage exceeding 1000V security requirements
GB/T 19258.1-2022 Ultraviolet radiation sources for sterilization Part 1: Low-pressure mercury vapor discharge lamps
JJG879-2015 UV radiation meter
HJ590-2010 Determination of ambient air ozone by ultraviolet photometry
3 Terms and definitions
The terms and definitions defined in GB/T 2900.65 and the following apply to this document.
3.1 Cold cathode ultraviolet germicidal lamp
A cold cathode glow discharge low-pressure mercury vapor discharge lamp using quartz glass or other transparent purple glass. The discharge produces a wavelength of ultraviolet radiation mainly at 253.7nm.
Note: Its ultraviolet radiation can kill bacteria and viruses. Effective sterilization and disinfection require a certain ultraviolet dose. The ultraviolet dose refers to the amount of radiation received per unit area of ultraviolet energy.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 20 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 2828.1-2012Sampling procedures for inspection by attributes - Part 1: Sampling schemes indexed by acceptance quality limit (AQL) for lot-by-lot inspection
- GB/T 2829-2002Sampling procedures and tables for periodic inspection by attributes
- GB/T 2900.65Electrotechnical terminology - Lighting
- GB/T 17263Self-ballasted lamps for general lighting service - Performance specifications
- GB/T 19149Transformers for tubular discharge lamps having a no-load output voltage exceeding 1 000 V(generally called neon-transformers)-General and safety requirements
- GB/T 19258.1-2022Ultraviolet radiation sources for germicidal purpose—Part 1: Low pressure mercury vapor discharge lamp
GB 16843 · GB 16844 · GB 18774
Similar standards
Editions of GB/T 19258.2
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB/T 19258.2-2023 | Ultraviolet radiation sources for germicidal purpose—Part 2: Cold cathode low pressure mercury vapor discharge lamp | current edition | Current |
| GB/T 28795-2012 | Ultraviolet radiation sources for germicidal purpose—Part 2: Cold cathode low pressure mercury vapor discharge lamp | previous edition | Superseded |
This page sells the current edition, GB/T 19258.2-2023. Earlier editions are listed for reference only.
How to Download GB/T 19258.2-2023
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 17263-2025 — Self-ballasted lamps for general lighting service - Performance specifications
GB/T 19149-2003 — Transformers for tubular discharge lamps having a no-load output voltage exceeding 1 000 V(generally called neon-transformers)-General and safety requirements
GB/T 19258.1-2022 — Ultraviolet radiation sources for germicidal purpose—Part 1: Low pressure mercury vapor discharge lamp
Secure payment via Stripe
Payments accepted
GB/T 19258.2-2023
$385.00