Scope
GB/T 16886.12-2023 is the English-translated version of 医疗器械生物学评价 第12部分:样品制备与参照材料.
GB/T 16886.12-2023 — This Document specifies requirements and gives guidance on the procedures in the preparation of samples and the selection of reference materials for medical device testing primarily in biological test systems primarily in accordance with one or more parts of the ISO 10993 series. Specifically, this document addresses the following.
Found what you need?
Document preview — GB/T 16886.12-2023
National Standard of the People's Republic of China
- ICS
- 11.100.20
Issued by: State Administration for Market Regulation
Contents
- Foreword...3
- Introduction...5
- 1 Scope...8
- 2 Normative References...8
- 3 Terms and Definitions...8
- 4 General Requirements...11
- 5 Reference Materials (RMs)...12
- 5.1 General...12
- 5.2 Certification of RMs for biological safety testing...12
- 6 Use of RMs as Experimental Controls...13
- 7 Test Sample Selection...13
- 8 Test Sample and RM Preparation...14
- 9 Selection of Representative Portions from a Medical Device...14
- 10 Preparation of Extracts of Samples...15
- 10.1 General...15
- 10.2 Containers for extraction...15
- 10.3 Extraction conditions and methods...15
- 10.4 Extraction conditions for materials that polymerize in situ...20
- 11 Records...20
- Annex A (Informative) Experimental Controls...22
Foreword
This Document was drafted as per the rules specified in GB/T 1.1-2020 Directives for
Standardization – Part 1.Rules for the Structure and Drafting of Standardizing Documents.
This Document is Part 12 of GB/T (Z) 16886 Biological Evaluation of Medical Devices. GB/T
(Z) 16886 consists of the following parts.
--- Part 1.Evaluation and testing within a risk management process;
--- Part 2.Animal welfare requirements;
--- Part 3.Tests for genotoxicity, carcinogenicity and reproductive toxicity;
--- Part 4.Selection of tests for interactions with blood;
--- Part 5.Tests for in vitro cytotoxicity;
--- Part 6.Tests for local effects after implantation;
--- Part 7.Ethylene oxide sterilization residuals;
--- Part 9.Framework for identification and quantification of potential degradation products;
--- Part 10.Tests for irritation and skin sensitization;
--- Part 11.Tests for systemic toxicity;
--- Part 12.Sample preparation and reference materials;
--- Part 13.Identification and quantification of degradation products from polymeric
medical devices;
--- Part 14.Identification and quantification of degradation products from ceramics;
--- Part 15.Identification and quantification of degradation products from metals and alloys;
--- Part 16.Toxicokinetic study design for degradation products and leachable;
--- Part 17.Establishment of allowable limits for leachable substances;
--- Part 18.Chemical characterization of medical device materials within a risk management
process;
--- Part 19.Physio-chemical, morphological and topographical characterization of materials;
--- Part 20.Principles and methods for immunotoxicology testing of medical devices;
--- Part 22.Nanomaterials guide;
--- Part 23.Tests for irritation.
This Document replaced GB/T 16886.12-2017 Biological Evaluation of Medical Devices - Part
12 Sample Preparation and Reference Materials. Compared with GB/T 16886.12-2017, the
major technical changes of this Documents are as follows besides the structural adjustments
and editorial modifications.
a) Change the "Scope" to cover only the extraction of biological evaluation tests (see Clause
1 of this Edition; Clause 1 of the 2017 Edition);
b) Delete the terms and definitions of "accelerated extraction" and "simulated use
extraction" (see 3.1 and 3.14 of the 2017 Edition); and change the definitions of "strict
extraction", "extreme extraction", "extractables" and "leachable" (see 3.3, 3.4, 3.7 and
3.9 of this Edition; 3.4, 3.5, 3.8 and 3.10 of the 2017 Edition);
c) Change the list items of extraction conditions (see 10.3.1 of this Edition; 10.3.1 of the
2017 Edition).
This Document equivalently adopts ISO 10993-12.2021 Biological Evaluation of Medical
Devices – Part 12.Sample Preparation and Reference Materials.
Please note some contents of this Document may involve patents. The issuing agency of this
Document shall not assume the responsibility to identify these patents.
This Document was proposed by National Medical Products Administration.
This Document shall be under the jurisdiction of National Technical Committee on Biological
Evaluation on Medical Device of Standardization Administration of China (SAC/TC 248).
Drafting organizations of this Document. Shandong Medical Device and Drug Packaging
Inspection Institute; and Sichuan University.
Chief drafting staffs of this Document. Liang Jie, Sun Xiaoxia, Sun Lingxiao, Yuan Tun, and
Qu Qiujin.
The historical editions replaced by this Standard are as follows.
--- GB/T 16886.12-2000 was first-time published in 2000; first-time revised in 2005; and
second-time revised in 2017.
--- It is third-time revised hereby.
1 Scope
This Document specifies requirements and gives guidance on the procedures in the preparation
of samples and the selection of reference materials for medical device testing primarily in
biological test systems primarily in accordance with one or more parts of the ISO 10993 series.
Specifically, this document addresses the following.
2 Normative References
There are no normative references in this Document.
3 Terms and Definitions
For the purposes of this Document, the following terms and definitions apply.
ISO and IEC maintain terminological databases for use in standardization at the following
addresses.
Substance that can be released from a medical device or material using either extraction
solvents or extraction conditions, or both, that are expected to be at least as aggressive as the
conditions of clinical use.
4 General Requirements
When identifying hazards and estimating risk in relation to medical devices, hazards that arise
from changes in the manufacturing process, or insufficient control of the manufacturing process,
shall be considered in the design and preparation of test samples, as described in ISO 14971.
5 Reference Materials (RMs)
Certification of a RM is a procedure that establishes the numerical or qualitative value of the
biological response of the material under the specified test conditions. This process serves to
validate the testing of the material for that particular response and results in the issuance of a
certificate.
6 Use of RMs as Experimental Controls
RMs or CRMs shall be used in biological tests as control materials to demonstrate the suitability
of a procedure to yield a reproducible response, i.e., positive or negative, or both. Any material
used in this way shall be characterized with each biological test procedure for which the use of
the material is desired.
7 Test Sample Selection
Testing shall be performed on the final product, representative samples from the final product,
materials processed in the same manner as the final product (see ISO 10993-1), or on
appropriate extracts of any of these. The choice of test sample shall be justified.
8 Test Sample and RM Preparation
Test samples and RMs shall be handled with care to prevent contamination. Any residue from
the manufacturing processes, intentional or unintentional additives or contaminants, shall be
considered integral to the medical device, medical device portion or component, or
representative sample.
9 Selection of Representative Portions from a Medical Device
When different materials are present in a single medical device, the potential for synergies
and interactions shall be considered in the choice of test sample.
10 Preparation of Extracts of Samples
The extraction shall be performed in clean, chemically inert, closed containers with minimum
dead space.
In the case of products that polymerize in situ, the samples to be tested shall represent the
intended clinical conditions of use in order to provide information on the potential toxicity of
the reacting components in the polymer during the curing process.
11 Records
Records of the sample and its preparation shall include, but not be limited to.
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 22 pages — is available in the English PDF.
Referenced standards
Cited by
- YY/T 1670.2-2025Neurotoxicity evaluation of medical devices - Part 2: Tests for neuro-cytotoxicity
- YY 0603-2024Cardiopulmonary bypass systems - Hard-shell cardiotomy/venous reservoirs (with or without filter) and soft venous reservoir bags
- YY/T 1535-2024Medical devices for human assisted reproductive technology - Human sperm viability assay (HSVA)
- GB 19083-2023Protective face masks for medical use
- YY/T 0127.19-2023Biological evaluation of medical devices used in dentistry - Part 19: Subacute and subchronic systemic toxicity test: implantation route
- YY/T 0606.15-2023Tissue engineered medical products - Standard practice for evaluation of immune response to matrices and scaffolds: lymphocyte proliferation test
How to Download GB/T 16886.12-2023
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 16886.1-2022 — Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management process
GB/T 16886.10-2024 — Biological evaluation of medical devices - Part 10: Tests for skin sensitization
GB/T 16886.11-2021 — Biological evaluation of medical devices - Part 11: Tests for systemic toxicity
Secure payment via Stripe
Payments accepted
GB/T 16886.12-2023
$300.00