YY/T 0127.4-2009Biological evaluation of medical devices used in dentistry - Part 2: Test method - Bone implant test (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (17 pages)

Need quotation for your management?

Get a formal quotation for YY/T 0127.4-2009 in 30 minutes.

Issued by

The State Food and Drug Administration

Level / Type

National · Recommended

Issue date

December 30, 2009

Implementation date

June 1, 2011

Scope

YY/T 0127.4-2009 (Biological evaluation of medical devices used in dentistry - Part 2: Test method - Bone implant test) is available as an English-translated PDF.

YY/T 0127.4-2009 — This Standard specifies the test method of bone implantation of dental medical devices. This Standard shall be used to evaluate the biological reactions of bone tissue of which the dental bone issue is planned to contact with dental medical devices in long-term.

Found what you need?

Document preview — YY/T 0127.4-2009

National Standard of the People's Republic of China

ICS
11.040.99
Classification
C 40

Issued by: The State Food and Drug Administration

Contents

  • Foreword...3
  • 1 Scope...6
  • 2 Normative References...6
  • 3 Sample Preparation...6
  • 4 Test Cycles...7
  • 5 Experimental Animals...7
  • 6 Test Position...7
  • 7 Surgical Procedure...8
  • 8 Post-operative Evaluation...8
  • 9 Killing of Animal...8
  • 10 Biological Reaction Evaluation...8
  • Appendix A...13
  • References...16
  • Translation References and Original Chinese Documents...17

Foreword

This Standard is one of the series standards of "Dental Medical device Biology

Assessment".

The 1st unit, YY/T 0268.2008 "Dentistry. Biological evaluation of medical devices used in

dentistry. Part 1.Evaluation and test" of Dental Medical device Biology Assessment series

standards, is an option for dental medical device biology assessment and test items; it is

a guideline standard.

The 2nd unit of the series standards is "Dental medical devices specific biological test

methods". It is divided into the following sections.

1 YY/T 0127.1-93 Dental materials biological test methods Hemolysis test

2 YY/T 0127.2-2009 Biological evaluation of medical devices used in dentistry. Part 2.

Test method. Acute systemic toxicity. intravenous path

3 YY/T 0127.3-1998 Biological evaluation of dental materials - Unit 2.Biological

evaluation method of dental materials - Endodontic usage test

4 YY/T 0127.4-2009 Biological evaluation of medical devices used in dentistry. Part 2.

Test method Bone implant test

5 YY/T 0127.5-1999 Biological evaluation of dental materials - Unit 2.Biological test

methods of dental materials - Inhalation toxicity test

6 YY/T 0127.6-1998 Biological evaluation of dental materials - Unit 2.Biological test

methods of dental materials - Dominant lethal test

7 YY/T 0127.7-2001 Biological evaluation of dental materials. Part 2.Biological evaluation

test method of dental materials. Pulp and dentine usage test

8 YY/T 0127.8-2001 Biological evaluation of dental materials. Part 2.Biological evaluation

test method of dental materials. Subcutaneous implant test

9 YY/T 0127.9-2009 Biological evaluation of medical devices used in dentistry. Part 2.

Test method - Cytotxicity tests. Agar diffusion test and filter diffusion test

10 YY/T 0127.10-2009 Biological evaluation of medical devices used in dentistry. Part 2.

Test method. Salmonella typhimurium reverse mutation assay (Ames mutagenicity test)

11 YY/T 0127.11-2001 Dentistry - Preclinical evaluation of biocompatibility of medical

devices used in dentistry. Part 2.Biological evaluation test method of dental materials -

Pulp capping test

12 YY/T 0127.12-2008 Dentistry. Biological evaluation of medical devices used in

dentistry Part 2.Test method - Micronucleus test

13 YY/T 0127.13-2009 Dentistry. Biological evaluation of medical devices used in

dentistry Part 2.Test method - Micronucleus test

14 YY/T 0244-1996 Biological test methods of dental materials - Short term systemic

toxicity test. dental route

15 YY/T 0127.14-2009 Biological evaluation of medical devices used in dentistry. Part 2.

Test method. Acute oral toxicity test

16 YY/T 0127.15-2009 Biological evaluation of medical devices used in dentistry. Part 2.

Test method Subacute and subchronic toxicity test - Oral route

This Standard is Part 4 of YY/T 0127 series standards.

This Standard is the revised version of YY/T 0127.4-1998 "Biological evaluation of medical

devices used in dentistry. Part 2.Test method Bone implant test". During the drafting

process, it references to the ISO 10993.6-2007 "Biological evaluation of medical devices -

Part 6.Tests for local effects after implantation". Test principles of ISO 10993.6-2007 are

applicable to this Standard.

Compared with the standard YY/T 0127.4-1998, the main changes are as follows.

- Standard name is renamed as. "Biological evaluation of medical devices used in dentistry.

Part 2.Test method Bone implant test".

- 3.1 Sample preparation adds samples with different types of materials. The sample

quantity number of each test cycle is changed to at least 10.

- 3.2, 4, 5, 6 add a variety of options.

- 7 During surgical procedure, "25g/L iodine and 75% ethanol" are changed to

"5g/L iodine".

- 10 Biological evaluation is modified.

- ADD Appendix A.

Appendix A is an informative appendix.

From the date of implementation, this Standard will replace the obsolete Y/T 0217.4-1998

"Biological evaluation of medical devices used in dentistry. Part 2.Test method - Bone

implant test".

This Standard was proposed by the State Food and Drug Administration.

This Standard is administered by the National Dental Materials and Appliances Equipment

Standardization Technical Committee (SAC/TC 99).

This Standard was responsibly drafted by Dental Medical Device Inspection Center,

School of Stomatology of Peking University.

1 Scope

This Standard specifies the test method of bone implantation of dental medical devices.

This Standard shall be used to evaluate the biological reactions of bone tissue of which the

dental bone issue is planned to contact with dental medical devices in long-term.

2 Normative References

The articles contained in the following documents have become part of this Standard when

they are quoted herein. For the dated documents so quoted, all the modifications (excluding

corrections) or revisions made thereafter shall not be applicable to this Standard. For the

undated documents so quoted, the latest edition shall be applicable to this Standard.

GB/T 13810 Wrought titanium and titanium alloy for surgical implants

GB/T 16886.6 Biological evaluation of medical devices - Part 6.Tests for local effects after

implantation (GB/T 16886.6-1997, ISO 10993-6.1994, IDDT)

GB/T 16886.12 Biological evaluation of medical devices - Part 12.Sample preparation and

reference materials (GB/T 16886.12 2005, ISO 10993-12.2005, IDT)

3 Sample Preparation

3.1 CONDUCT preparation, processing, cleaning, and disinfection for the implanted

materials according to the same method used for final product. At least 10 samples shall be

used for each test cycle.

3.1.1 Solid sample. sample shall be made in cylinder with diameter of 2 mm, height of 6 mm,

with smooth surface.

same position; so as to ensure the minimum influence of relative movement between tissue

and the implants.

For cylindrical sample, the observation position shall be at the central part of the column; for

slotted cylindrical implants, the central part of the slot and the top flat surface are suitable

for evaluation.

10.1 Visual evaluation

USE low-magnification loupe to observe the cut tissue from the implanting position; it shall

include the evaluation of local draining lymph nodes. RECORD the characteristics and

degree of the observed tissue reaction, including hematoma, edema, fiber wrapping and (or)

any general findings. RECORD the implant's state, shape and location, including the

possible residues of biodegradable materials. Observation results shall be archived with

photographs.

In addition, when observing the implanting position, if the animal exhibits pathological or

reaction to the implant, gross necropsy shall be carried out if necessary.

10.2 Sampling and preparation of tissue sample

In order to evaluate the local biological reaction, cut tissue samples shall include those

sufficient unaffected tissue from the implanting position and surrounding areas.

If the implant is not obvious in the observation position (biodegradable material/ absorbable

material), it shall expand the sampling area, including those normal tissue located within few

millimeters. For non-degradable materials, it shall include the abnormal draining lymph

nodes shown by the result of gross pathology. For biod...

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 17 pages — is available in the English PDF.

Referenced standards

How to Download YY/T 0127.4-2009

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
17 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YY/T 0127.4-2009

$115.00