GB/T 16886.11-2021Biological evaluation of medical devices - Part 11: Tests for systemic toxicity (English PDF)
Also coversGBT16886.11-2021
Open the GB/T 16886.11-2021 preview as PDF
This is a limited preview
Buy now to download the full PDF
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
November 26, 2021
Implementation date
December 1, 2022
Scope
GB/T 16886.11-2021 (Biological evaluation of medical devices - Part 11: Tests for systemic toxicity) is available as an English-translated PDF.
GB/T 16886.11-2021 — This document specifies requirements and gives guidance on procedures to be followed in the evaluation of the potential for medical device materials to cause adverse systemic reactions.
Document preview — GB/T 16886.11-2021
National Standard of the People's Republic of China
Issued by: SAMR; SAC
Contents
- Foreword...4
- Introduction...6
- 1 Scope...9
- 2 Normative references...9
- 3 Terms and definitions...9
- 4 General considerations...11
- 4.1 General...11
- 4.2 Selection of animal species...12
- 4.3 Animal status...12
- 4.4 Animal care and husbandry...12
- 4.5 Size and number of groups...13
- 4.5.1 Size of groups...13
- 4.5.2 Number of groups...13
- 4.5.3 Treatment controls...14
- 4.6 Route of exposure...14
- 4.7 Sample preparation...14
- 4.8 Dosing...14
- 4.8.1 Test sample administration...14
- 4.8.2 Dosage volumes...15
- 4.8.3 Dosage frequency...15
- 4.9 Body weight and food/water consumption...16
- 4.10 Clinical observations...16
- 4.11 Clinical pathology...16
- 4.12 Anatomic pathology...17
- 4.13 Study designs...17
- 4.14 Quality of investigation...17
- 5 Acute systemic toxicity...18
- 5.1 General...18
- 5.2 Study design...18
- 5.2.1 Preparations...18
- 5.2.2 Experimental animals...18
- 5.2.3 Test conditions...19
- 5.2.4 Body weights...19
- 5.2.5 Clinical observations...19
- 5.2.6 Pathology...20
- 5.3 Evaluation criteria...21
- 5.3.1 General...21
- 5.3.2 Evaluation of results...21
- 5.4 Final report...22
Foreword
This document is drafted in accordance with GB/T 1.1-2020 "Directives for
standardization - Part 1.Rules for the structure and drafting of standardizing
documents".
The document is Part 11 of GB/T 16886 "Biological evaluation of medical devices".
GB/T 16886 has issued the following parts.
- Part 1.Evaluation and testing within a risk management process;
- Part 2.Animal welfare requirements;
- Part 3.Tests for genotoxicity, carcinogenicity and reproductive toxicity;
- Part 4.Selection of tests for interactions with blood;
- Part 5.Tests for in vitro cytotoxicity;
- Part 6.Tests for local effects after implantation;
- Part 7.Ethylene oxide sterilization residuals;
- Part 9.Framework for identification and quantification of potential degradation
products;
- Part 10.Tests for irritation and skin sensitization;
- Part 11.Tests for systemic toxicity;
- Part 12.Sample preparation and reference materials;
- Part 13.Identification and quantification of degradation products from polymeric
medical devices;
- Part 14.Identification and quantification of degradation products from ceramics;
- Part 15.Identification and quantification of degradation products from metals and
alloys;
- Part 16.Toxicokinetic study design for degradation products and leachables;
- Part 17.Establishment of allowable limits for leachable substances;
- Part 18.Chemical characterization of materials;
- Part 19.Physico-chemical, morphological and topographical characterization of
materials;
- Part 20.Principles and methods for immunotoxicology testing of medical devices.
This document replaces GB/T 16886.11-2011 "Biological evaluation of medical
devices - Part 11.Tests for systemic toxicity". Compared with GB/T 16886.11-2011,
the main technical change is as follows.
- Modify the size of groups for chronic toxicity tests (see Table 1; Table 1 of the
2011 edition).
This document, using translation method, is identical to ISO 10993-11.2017
"Biological evaluation of medical devices - Part 11.Tests for systemic toxicity".
China's documents which have a consistent correspondence with the international
documents normatively referenced in this document are as follows.
- GB/T 16886.1-2011 Biological evaluation of medical devices - Part 1.Evaluation
and testing within a risk management process (ISO 10993-1.2009, IDT);
- GB/T 16886.2-2011 Biological evaluation of medical devices - Part 2.Animal
welfare requirements (ISO 10993-2.2006, IDT).
Attention is drawn to the possibility that some of the elements of this document may be
the subject of patent rights. The issuing authority of this document shall not be held
responsible for identifying any or all such patent rights.
This document was proposed by National Medical Products Administration.
This document shall be under the jurisdiction of National Technical Committee 248 on
Biological Evaluation of Medical Devices of Standardization Administration of China
(SAC/TC 248).
Drafting organizations of this document. Shandong Quality Inspection Center for
Medical Devices, National Institutes for Food and Drug Control.
Main drafters of this document. Wang Xin, Sun Likui, Han Qianqian, Wang Han, Chu
Xiangyu, Xu Jing.
The previous releases of this document and the documents it replaces are as follows.
- It was first issued in 1997 as GB/T 16886.11-1997 and first revised in 2011;
- This is the second revision.
1 Scope
This document specifies requirements and gives guidance on procedures to be followed
in the evaluation of the potential for medical device materials to cause adverse systemic
reactions.
2 Normative references
The contents of the following documents, through normative references in this text,
constitute indispensable provisions of this document. Among them, for dated references,
only the edition corresponding to that date applies to this document. For undated
references, the latest edition (including all amendments) applies to this document.
ISO 10993-1 Biological evaluation of medical devices - Part 1.Evaluation and
testing within a risk management process
3 Terms and definitions
For the purposes of this document, the terms and definitions given in ISO 10993-1 and
the following apply.
Relationship between the dosage and the magnitude of a defined biological effect either
in an individual or in a population sample.
4 General considerations
There is no absolute criterion for selecting a particular animal species for systemic
toxicity testing of medical devices. However, the species used shall be scientifically
justified and in line with the provisions of ISO 10993-2.
Depending on the objective of the study, the nature of the test article and the route of
exposure, negative, vehicle and/or sham-treated controls should be incorporated into all
systemic toxicity studies.
5 Acute systemic toxicity
Healthy young adult animals are acclimatized to the laboratory conditions for at least 5
d prior to the test. Shorter durations shall be justified. Animals are then randomized and
assigned to the treatment groups.
6 Repeated exposure systemic toxicity (subacute, subchronic and chronic systemic toxicity)
The dose to use for toxicity tests of medical devices shall be defined in relation to the
results of risk assessment, balancing the clinical exposure dose with the use of safety
factors, as applicable. Except for treatment with the test substance, animals in the
control group should be handled in an identical manner to the test group subjects.
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.
Referenced standards
Normative references
ISO 10993
Cited by
- GB/T 45481-2025Silicone rubber compounds for medical catheters
- YY 0580-2024Cardiovascular implants and artificial organs - Cardiopulmonary bypass systems - Arterial line blood filters
- YY 0603-2024Cardiopulmonary bypass systems - Hard-shell cardiotomy/venous reservoirs (with or without filter) and soft venous reservoir bags
- YY/T 0127.19-2023Biological evaluation of medical devices used in dentistry - Part 19: Subacute and subchronic systemic toxicity test: implantation route
- YY/T 0730-2023Cardiovascular implants and artificial organs - Requirements for single-use tubing packs used in cardiopulmonary bypass and extracorporeal membrane oxygenation (ECMO)
- GB/T 16886.1-2022Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management process
How to Buy GB/T 16886.11-2021
- 1Add to cart. Click the "Buy GB/T 16886.11-2021" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 16886.1-2022 — Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management process
GB/T 16886.10-2024 — Biological evaluation of medical devices - Part 10: Tests for skin sensitization
GB/T 16886.15-2022 — Biological evaluation of medical devices - Part 15: Identification and quantification of degradation products from metals and alloys
Secure payment via Stripe
Payments accepted
GB/T 16886.11-2021
$425.00