Scope

GB/T 12160-2019 (Metallic materials - Calibration of extensometers systems used in uniaxial testing) is available as an English-translated PDF.

GB/T 12160-2019 — This Standard specifies a method for the static calibration of extensometer systems used in uniaxial testing, including axial and diametral extensometer systems, both contacting and non- contacting.

Document preview — GB/T 12160-2019

National Standard of the People's Republic of China

Issued by: SAMR; SAC

Contents

  • Foreword...4
  • Introduction...5
  • 1 Scope...6
  • 2 Terms and Definitions...6
  • 3 Symbols and Designations...6
  • 4 Principle...7
  • 5 Calibration Equipment...7
  • 5.1 Calibration Apparatus...7
  • 5.2 Calibration Traceability...8
  • 6 Pre-calibration Inspection...8
  • 6.1 Objective...8
  • 6.2 Records of the Inspection...8
  • 6.3 Identification of Extensometer System Elements...8
  • 7 Measurement of Extensometer Gauge Length...9
  • 7.1 Fixed Gauge Length Extensometry...9
  • 7.2 Variable Gauge Length Extensometry...9
  • 7.3 Non-contacting Extensometry...10
  • 7.4 Extensometer Gauge Lengths Established Using Setting Gauges...10
  • 8 Calibration Process...10
  • 8.1 Environmental Considerations...10
  • 8.2 Position of the Extensometer...11
  • 8.3 Calibration Increments...11
  • 8.4 Calibration Process...12
  • 8.5 Determination of the Characteristics of the Extensometer System...13
  • 9 Classification of the Extensometer System...14
  • 9.1 Input Data...14
  • 9.2 Analysis of the Data...14
  • 9.3 Classification Criteria...14
  • 9.4 Assessment of the Results...15
  • 10 Uncertainty Determination...15
  • 10.1 Uncertainty of the Calibration...15
  • 10.2 Uncertainty Budget Determination...16
  • 11 Extensometer System Calibration Intervals...16
  • 12 Calibration Certificate...16
  • 12.1 Mandatory Information...16
  • 12.2 Data Presentation...17
  • Annex A (informative) Uncertainty of Measurement...18
  • Annex B (informative) Calibration of the Calibration Apparatus...24

Foreword

This Standard was drafted in accordance with the rules provided in GB/T 1.1-2009.

This Standard serves as a replacement for GB/T 12160-2002 Calibration of Extensometers

Used in Uniaxial Testing. In comparison with GB/T 12160-2002, apart from editorial

modifications, the main technical changes are as follows.

---Terms and definitions are added (see Chapter 2);

---Pre-calibration inspection is added (see Chapter 6);

---Uncertainty determination is added (see Chapter 10);

---Annex A "Example of Extensometer Calibration Range" and Annex B "Parameters for

Extensometer Classification" are deleted (see Annex A and Annex B of Version 2002);

---Informative Annexes are added (see Annex A, Annex B, Annex C, Annex D, Annex E,

Annex F, Annex G and Annex H).

This Standard uses the translation method in the equivalent adoption of ISO 9513.2012 Metallic

Materials - Calibration of Extensometer Systems Used in Uniaxial Testing.

This Standard makes the following editorial modification.

---This Standard includes ISO 9513.2012_Cor 1 and corrects some contents of Figure C.1

and Figure C.2.

This Standard was proposed by China Machinery Industry Federation.

This Standard shall be under the jurisdiction of National Technical Committee 122 on Testing

Machines of Standardization Administration of China (SAC/TC 122).

The drafting organizations of this Standard. SINOTEST Equipment Co., Ltd.; Central Iron &

Steel Research Institute; Wuxi Institute of Measurement and Testing; Shenzhen WANCE testing

Machine Co., Ltd.; Jilin University; Jilin Institute of Metrology.

1 Scope

This Standard specifies a method for the static calibration of extensometer systems used in

uniaxial testing, including axial and diametral extensometer systems, both contacting and non-

contacting.

2 Terms and Definitions

For the purposes of this document, the following terms and definitions apply.

equipment used to measure displacement or strain on the surface of a test piece.

3 Symbols and Designations

Symbols used throughout this Standard are given in Table 1 together with their designation.

4 Principle

The calibration of extensometer systems involves a comparison of the readings given by the

extensometer with known variations in length provided by a calibration apparatus.

5 Calibration Equipment

The calibration apparatus, which allows a known displacement lt to be applied to the

extensometer, may consist of a rigid frame with suitable coaxial spindles or other fixtures to

which the extensometer can be attached. The calibration apparatus shall comprise a mechanism

for moving at least one of the axial spindles together with a device for accurately measuring the

change in length produced.

6 Pre-calibration Inspection

Records of the pre-calibration inspection shall be kept, identifying the "as-found" condition of

the extensometer system, when the inspection was performed and who performed it. These pre-

calibration inspection records can take the form of either a written report or a completed "pro-

forma" checklist.

7 Measurement of Extensometer Gauge Length

The gauge length for non-contacting extensometry is established in accordance with the

manufacturer's instructions.

Where an extensometer gauge length is set using a removable gauge, the relative error on the

gauge length, qLe, calculated from Formula (1) shall not exceed the values given in Table 2.

8 Calibration Process

The extensometer shall be placed, wherever feasible, in the calibration apparatus in a similar

orientation to that in which it will be used during uniaxial testing to avoid errors due to loss of

equilibrium or to deformation of any part of the extensometer.

The extensometer shall be attached in a similar way as during uniaxial testing.

9 Classification of the Extensometer System

The required input data for the classification of the extensometer system are.

The collated data are assessed as follows.

10 Uncertainty Determination

Many elements contribute to the uncertainty of the calibration process. The following shall be

assessed and incorporated into the uncertainty budget calculation.

11 Extensometer System Calibration Intervals

11.1 The time between two calibrations depends on the type of extensometer system, the

maintenance standard and the number of times the extensometer system has been used. Under

normal conditions, it is recommended that calibration be carried out at intervals of

approximately 12 months.

12 Calibration Certificate

The calibration certificate shall contain at least the following information.

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.

Referenced standards

Cited by

How to Buy GB/T 12160-2019

  1. 1Add to cart. Click the "Buy GB/T 12160-2019" button on this page. You can add more standards before checkout.
  2. 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
  3. 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
  4. 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 12160-2019

$620.00

$525.00for partners