GB/T 46063-2025Continuous fiber reinforced ceramic matrix composite - Test method for hoop tensile properties of tubes at room temperature (English PDF)
This is a limited preview
Buy now to download the full PDF (17 pages)
Need quotation for your management?
Get a formal quotation for GB/T 46063-2025 in 30 minutes.
Issued by
State Administration for Market Regulation
Level / Type
National · Recommended
Issue date
August 29, 2025
Implementation date
March 1, 2026
Scope
GB/T 46063-2025 (Continuous fiber reinforced ceramic matrix composite - Test method for hoop tensile properties of tubes at room temperature) is available as an English-translated PDF.
GB/T 46063-2025 — This document describes a method for testing the room temperature circumferential tensile properties of continuous fiber-reinforced ceramic matrix composite tubular samples.
Composite tubing the fiber braiding structure and sample geometry of the sample differ from those of the flat plate sample; therefore, this method is only applicable to the circumferential tensile testing of composite tubular samples.
Performance testing. This document describes the circumferential tensile properties (such as circumferential tensile strength and circumferential fracture stress) of continuous fiber reinforced ceramic matrix composite tube samples.
Test methods for (variable, circumferential elastic modulus and Poisson's ratio). This document applies to the circumferential tensile properties of unidirectional, bidirectional, or multidirectional continuous fiber reinforced ceramic matrix and/or glass matrix composite tubing. Measurement.
Found what you need?
Document preview — GB/T 46063-2025
National Standard of the People's Republic of China
- ICS
- 81.060.30
- Classification
- Q 30
Issued by: State Administration for Market Regulation
Contents
- Preface
- 1 Scope
- 2 Normative References
- 3 Terms and Definitions
- 4 Principle
- 5 Instruments and Equipment
- 5.1 Pressurization System
- 5.2 Sample fixing and end sealing device
- 5.3 Strain Measurement
- 5.4 Pressure and Data Recording System
- 5.5 Dimensional Measurement
- 6 Pipe samples
- 6.1 Sample Specifications
- 6.2 Sample Preparation
- 6.3 Sample Quantity and Sampling
- 7 Experimental Procedures
- 7.1 General Rules
- 7.2 Loading Method and Loading Rate
- 7.3 Experimental Procedure
- 7.4 Test Validity
- 8 Result Calculation
- 8.1 Sample Schematic Diagram
- 8.2 Circumferential Tensile Stress and Tensile Strain
- 8.3 Circumferential tensile strength and fracture strain
- 8.4 Circumferential elastic modulus
- 8.5 Poisson's ratio (optional)
- 8.6 Mean, Standard Deviation, and Coefficient of Variation
- 9 Test Report
- Appendix A (Informative) Comparison of this document with ISO 21971:2019 structural numbering
- Appendix B (Informative) Technical Differences Between This Document and ISO 21971:2019 and Their Reasons
- Reference
Foreword
This document complies with the provisions of GB/T 1.1-2020 "Standardization Work Guidelines Part 1: Structure and Drafting Rules of Standardization Documents".
Drafting.
This document is modified to adopt ISO 21971:2019 "Fine ceramics (advanced ceramics, advanced technical ceramics) - Ceramic matrix composites - Room temperature and humidity control".
Determination of the circumferential tensile properties of pipes under compression mechanical properties.
Compared with ISO 21971:2019, this document has undergone many structural adjustments. A table comparing the changes in structural numbering between the two documents is provided.
See Appendix A.
This document differs significantly from ISO 21971:2019.The relevant clauses are indicated in vertical margins.
Single lines (-) are indicated. A summary of these technical differences and their causes can be found in Appendix B.
The following editorial changes have been made to this document.
---To align with existing standards, the standard name has been changed to "Room Temperature Circumferential Tensile Properties of Continuous Fiber Reinforced Ceramic Matrix Composite Pipes".
Test Methods;
---Notes in sections 3.11, 5.3.2.1, 5.3.2.2, 5.3.3.4, 6.1.4, 7.3.1, and 7.3.5 of ISO 21971:2019 have been removed;
---All headings in Chapter 9 of ISO 21971:2019 have been removed, and test reports are presented in list format;
---Appendix A (informative) "Comparison of Structure Numbers in this Document with ISO 21971:2019" has been added;
---Added Appendix B (Informative) "Technical Differences between this Document and ISO 21971:2019 and Their Reasons".
Please note that some content in this document may involve patents. The issuing organization of this document assumes no responsibility for identifying patents.
This document was proposed by the China Building Materials Federation.
This document is under the jurisdiction of the National Technical Committee on Standardization of Industrial Ceramics (SAC/TC194).
1 Scope
This document describes a method for testing the room temperature circumferential tensile properties of continuous fiber-reinforced ceramic matrix composite tubular samples. Composite tubing the fiber braiding structure and sample geometry of the sample differ from those of the flat plate sample; therefore, this method is only applicable to the circumferential tensile testing of composite tubular samples.
Performance testing.
This document describes the circumferential tensile properties (such as circumferential tensile strength and circumferential fracture stress) of continuous fiber reinforced ceramic matrix composite tube samples.
Test methods for (variable, circumferential elastic modulus and Poisson's ratio).
This document applies to the circumferential tensile properties of unidirectional, bidirectional, or multidirectional continuous fiber reinforced ceramic matrix and/or glass matrix composite tubing.
Measurement.
2 Normative references
The contents of the following documents, through normative references within the text, constitute essential provisions of this document. Dated citations are not included.
For references to documents, only the version corresponding to that date applies to this document; for undated references, the latest version (including all amendments) applies.
This document.
GB/T 1216 Outside Micrometer GB/T 12160 Calibration of extensometer systems for uniaxial testing of metallic materials (GB/T 12160-2019, ISO 9513:2012) IDT) GB/T 17991 Terminology for Fine Ceramics (GB/T 17991-2009, ISO 20507:2022, MOD) GB/T 21389 Vernier, dial indicator and digital calipers GB/T 22093 Electronic Digital Micrometer
3 Terms and Definitions
The terms and definitions defined in GB/T 17991 and the following terms and definitions apply to this document.
calibrated length
The length of the sample with a uniform, minimum cross-sectional area.
gauge length
The initial distance between reference points within the calibration length.
outer diameterexternaldiameter do the diameter of the outer circle of the cross-section of the tubular sample within the gauge length.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 17 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 1216External micrometer
- GB/T 12160Metallic materials - Calibration of extensometers systems used in uniaxial testing
- GB/T 12160-2019Metallic materials - Calibration of extensometers systems used in uniaxial testing
- GB/T 21389Vernier, dial and digital display calipers
- GB/T 22093Internal micrometer with electronic digital display
ISO 9513 · GB/T 17991 · GB/T 17991-2009 · ISO 20507
How to Download GB/T 46063-2025
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 1216-2018 — External micrometer
GB/T 12160-2019 — Metallic materials - Calibration of extensometers systems used in uniaxial testing
GB/T 12162.1-2025 — X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy - Part 1: Radiation characteristics and production methods
Secure payment via Stripe
Payments accepted
GB/T 46063-2025
$350.00