GB/T 33812-2017Metallic material -- Fatigue testing -- Strain-controlled thermomechanical fatigue testing method (English PDF)
Also coversGBT33812-2017
Open the GB/T 33812-2017 preview as PDF
This is a limited preview
Buy now to download the full PDF
Issued by
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Level / Type
National · Recommended
Issue date
May 31, 2017
Implementation date
December 1, 2017
Scope
GB/T 33812-2017 (Metallic material -- Fatigue testing -- Strain-controlled thermomechanical fatigue testing method) is available as an English-translated PDF.
GB/T 33812-2017 — This standard specifies the requirements for thermomechanical fatigue tests of uniaxially loaded metal specimens under strain control. This standard applies to constant mechanical strain and temperature cycling conditions, corresponding to any constant cycle strain ratio and constant temperature - mechanical Variable phase difference test. The cycle is usually considered in the category of low cycle fatigue, ie fatigue life Nf <= 105. Note 1. Appendix A lists the most common cycle type diagrams. Note 2. The temperature of the test is generally not more than 1200 ° C.
Document preview — GB/T 33812-2017
National Standard of the People's Republic of China
- ICS
- 77.040.10
- Classification
- H 22
Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Contents
- Foreword
- Introduction
- 1 Scope
- 2 normative reference documents
- 3 terms and definitions
Foreword
This standard is drafted in accordance with the rules given in GB/T 1.1-2009.
This standard uses the re-drafting method to modify the use of ISO 12111..2011 (E) "metal material fatigue test strain control thermomechanical fatigue
Labor test method "(English version).
This standard is in line with international standards, the contents of the international standards in the following aspects of the modified and added, and in the text it
The blanks of the terms of the articles are marked with vertical lines.
- Added in Chapter 1 "Note 2. The temperature of the test is generally not more than 1200 ° C";
--- on the normative reference documents, this standard has made a technical differences in the adjustment to meet China's technical conditions, the adjustment of the situation
Is reflected in Chapter 2, "normative reference documents", the specific adjustments are as follows.
* the use of the date of reference to the use of international standards of our standard GB/T 12160-2002 instead of the date of reference
Corresponding international standard ISO 9513;
* Added references to documents GB/T 25917, JJG141, JJG351 and JJG617;
--- delete the note of 3.16;
- Chapter 4 adds the symbols for "parallel length" and "number of cycles", while increasing the flexibility, inelastic, and plasticity of the footer
(See Table 1);
- the relevant provisions for the calibration of the sensor and its associated electrical appliances (see 5.5);
- Figure 5 and Figure 6 are added in 6.1.2.7.
This standard has made the following editorial changes.
- For ease of use, give Chapter 4 symbols in tabular form (see Table 1), and the typical sample size in 6.1.2.2
(See Table 2), while the ISO standard in Table 1 to Table 3.
This standard is proposed by China Iron and Steel Industry Association.
This standard is under the jurisdiction of the National Steel Standardization Technical Committee (SAC/TC183).
The drafting of this standard unit. Iron and Steel Research Institute, Beijing Institute of Aeronautical Materials, Metallurgical Industry Information Standards Institute.
Introduction
The fatigue life of the components subjected to both thermal and mechanical effects often draws a great deal of attention to the design engineer. Research materials are subject to heat load and machine
The common method of simultaneous performance of the load is to idealize the state of the key material on the uniaxial specimen. The condition of the test is to circulate
The process is theoretically unchanged in the test section, and the temperature and strain fields are externally applied to control their simultaneous changes. This test is defined as "heat engine
Fatigue test ", often referred to as TMF.
In order to ensure the reliability of the test results and the consistency of the results of different laboratories, in accordance with the uniform standard of the test method to obtain and mining
Set the data is very necessary.
This standard also provides advice on the acquisition and presentation of TMF data.
Metal material fatigue test strain control
Thermal mechanical fatigue test method
1 Scope
This standard specifies the requirements for thermomechanical fatigue tests of uniaxially loaded metal specimens under strain control.
This standard applies to constant mechanical strain and temperature cycling conditions, corresponding to any constant cycle strain ratio and constant temperature - mechanical
Variable phase difference test.
The cycle is usually considered in the category of low cycle fatigue, ie fatigue life Nf <= 105.
Note 1. Appendix A lists the most common cycle type diagrams.
Note 2. The temperature of the test is generally not more than 1200 ° C.
2 normative reference documents
The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article
Pieces. For undated references, the latest edition (including all modifications) applies to this document.
GB/T 10623 Mechanical properties test for metallic materials (GB/T 10623-2008, ISO 23718..2007, MOD)
GB/T 12160-2002 Calibration of extensometer for uniaxial test (ISO 9513..1999, IDT)
GB/T 16825.1-2008 Tests for static uniaxial testing machines - Part 1. Tensile and/or pressure testing machines
Inspection and calibration (ISO 7500-1..2004, IDT)
GB/T 25917 Axial afterburner fatigue testing machine Dynamic force calibration (GB/T 25917-2010, ISO 4965. 1979, MOD)
GB/T 26077 Fatigue test of metallic materials - Axial strain control method (GB/T 26077-2010, ISO 12106..2003,
MOD)
JJG141 work with precious metal thermocouple
JJG351 work with cheap metal thermocouple
JJG617 digital temperature indication adjustment
3 terms and definitions
GB/T 10623 and GB/T 26077, as well as the following terms and definitions, apply to this document.
3.1
Stress
Fi/A0 is defined as stress, where Fi is the instantaneous force and A0 is the original cross-sectional area at room temperature.
3.2
Original elevation from originalgaugelength
L0
At room temperature and zero strain, the extensometer measures the length of the sample between points.
Note. This definition avoids the complexity of continuous variations in gauge length due to thermal expansion and cold shrinkage.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.
Referenced standards
How to Buy GB/T 33812-2017
- 1Add to cart. Click the "Buy GB/T 33812-2017" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 46830.2-2026 — Plastics - Liquid crystal polymer (LCP) moulding and extrusion materials - Part 2: Preparation of test specimens and determination of properties
GB/T 28593-2026 — Sand and dust weather warning levels
GB/T 19608.3-2026 — Classification of special environmental conditions - Part 3: Plateau
Secure payment via Stripe
Payments accepted
GB/T 33812-2017
$360.00