GB/T 10515-2012Determination of particle size for nitrophosphate (English PDF)
硝酸磷肥粒度的测定
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 10515-2012 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
December 31, 2012
Implementation date
June 1, 2013
Scope
GB/T 10515-2012 is the English-translated version of 硝酸磷肥粒度的测定.
GB/T 10515-2012 is the Chinese standard "Determination of particle size for nitrophosphate". Its scope clause reads: This standard specifies the determination of granular fertilizer nitrate, P and K particle size by sieving.
This standard applies to all kinds of technology, the granular fertilizer nitrate, P and K Determination of particle size. Its clauses include instrument; steps; expression analysis.
Found what you need?
Document preview — GB/T 10515-2012
National Standard of the People's Republic of China
- ICS
- 65.080
- Classification
- G 20
- Replacing
- GB/T 10515-1989
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Principle
- 4 Instrument
- 5 Steps
- 6 Expression analysis
Foreword
This standard is one nitrate fertilizer, P and K series of standard test methods for nitrate, which are listed below national standards.
--- GB/T 10511-2008 "After distillation of total nitrogen content for nitrophosphate titration method";
--- GB/T 10512-2008 "nitrate fertilizer phosphorus content - Quinoline phosphomolybdate gravimetric method";
--- GB/T 10513-2012 "nitrophosphate determination of water content Karl Fischer method";
--- GB/T 10514-2012 "nitrophosphate determination of water content - Oven method";
--- GB/T 10516-2012 "nitrate fertilizer particles have an average crush strength of determination."
This standard rule according to GB/T 1.1-2009 given draft.
This standard replaces GB/T 10515-1989 "Nitrophosphates size determination."
The main differences between this standard and the 1989 version are.
--- By a particle size range 1.00mm ~ 4.00mm to 1.00mm ~ 4.75mm.
The standard proposed by China Petroleum and Chemical Industry Association.
1 Scope
This standard specifies the determination of granular fertilizer nitrate, P and K particle size by sieving.
This standard applies to all kinds of technology, the granular fertilizer nitrate, P and K Determination of particle size.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated edition applies to this article Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 6003.1-1997 woven wire mesh test sieve (eqvISO 3310-1.1990)
3 Principle
By sieving method, particulate nitrate fertilizer, P and K nitrate into different particle diameters, weighing, calculate the mass fraction.
4 Instrument
4.1 Usually laboratory instruments.
4.2 balance, a sense of the amount of 0.5g.
4.3 test sieve (GB/T 6003.1-1997R40/3 series). a pore diameter of 1.00mm, 2.00mm, 2.80mm, 4.75mm sieve of Sub-set, with screen cover and chassis.
4.4 Sieve shaker.
5 Steps
Press sieve 1.00mm, 2.00mm, 2.80mm and 4.75mm aperture sequentially folded from the bottom, saying that reduction of sub-sample taken after About 200g, accurate to 1g, pore size is placed on the 4.75mm sieve, sieve cover lid placed on the sieve shaker, clamping, vibration 5min, will not By weighing the sample aperture 4.75mm sieve and chassis, caught in the mesh of the sieve through which particles are not counted. Reserved 2.00mm aperture Sample sieve, as the average particle crush strength measurement.
NOTE: If there is no vibration sieve, vibrating sieve can be used manually, but using a sieve shaker arbitration.
6 Expression analysis
Phosphate nitrate, P and K in size (w), to 1.00mm ~ 4.75mm accounted sample particle mass fraction, in% Table Shows, according to equation (1).
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Similar standards
Editions of GB/T 10515
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB/T 10515-2012 | Determination of particle size for nitrophosphate | current edition | Current |
| GB/T 10515-1989 | Determination of particle size for nitrophosphate | previous edition | Superseded |
This page sells the current edition, GB/T 10515-2012. Earlier editions are listed for reference only.
How to Download GB/T 10515-2012
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 10004-2026 — Plastic/Plastic laminated films and pouches for packaging
GB/T 10007-2026 — Rigid cellular plastics - Determination of shear properties
Secure payment via Stripe
Payments accepted
GB/T 10515-2012
$75.00