GB/T 10491-2010 is the English-translated version of 航空派生型燃气轮机成套设备噪声值及测量方法.

GB/T 10491-2010 is the Chinese standard "Noise criteria and sound measurement procedures for aero-derivative gas turbines turnkey installations". Its scope clause reads: This standard specifies the aviation derivative gas turbine equipment (hereinafter.

GT) noise level limits and measurement methods, yet It provides data processing method and measurement reporting requirements for turbine noise. This standard applies to power generation and mechanical drive gas turbines, is unsuitable as a means of transport (vehicles and ships, etc.) powered by fuel Gas turbine. Its clauses include terms and definitions; noise level limit.

Found what you need?

Document preview — GB/T 10491-2010

National Standard of the People's Republic of China

ICS
27.040
Classification
K 56
Replacing
GB/T 10491-1989

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • 2 Normative references

1 Scope

This standard specifies the aviation derivative gas turbine equipment (hereinafter. GT) noise level limits and measurement methods, yet

It provides data processing method and measurement reporting requirements for turbine noise.

This standard applies to power generation and mechanical drive gas turbines, is unsuitable as a means of transport (vehicles and ships, etc.) powered by fuel

Gas turbine.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent

Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research

Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.

GB 3102.7 acoustic quantity and unit (GB 3102.7-1993, eqv ISO 31-7.1992)

GB/T 3241 electro-acoustics octave and fractional octave filters (GB/T 3241-2010, IEC 61260.1995, MOD)

GB/T 3785 (all parts), electric acoustic sound level meter [GB/T 3785-2010, IEC 61672 (all parts), IDT]

GB/T 3947 Acoustics Terminology

GB/T 10489 General requirements for light turbine

GB 14098-1993 turbine noise

3 Terms and Definitions

Gas turbine terms and definitions GB/T 3947 and GB 3102.7 acoustics terms and definitions established and GB/T 10489 established appropriate

For this standard.

4 noise level limit

4.1

standard with A-weighted sound level (hereinafter referred to as. A sound level) as an evaluation value. If desired, an optional measure sound pressure level (C sound level) and

Octave band sound pressure level, but not as a basis for evaluation.

4.2

at full load and stable operation of the gas turbine, the average noise level at 1m away from the acoustic hood should not exceed 85dB (A). Gas turbine compartment

Acoustic hood 1m at the noise level limit value should be based on Standard of noise at boundary of industrial enterprises in the region to install the unit performed, or urban area ring

Environmental noise standards, taking into account the distance unit acoustic cover plant community, as well as on noise transmission Movies gas turbine plant or insulation of sound barrier

Sound, calculated by the purchaser after the presentation and after consultation with the contractor OK.

4.3

should be based on the specific circumstances of the plant boundary noise or environmental requirements and on-site, after calculation, made by the purchaser and in consultation with the contractor for fuel

Gas turbine noise level limit the following components at the outer 1m make provisions for. air intake, exhaust diffuser, acoustic cover vents and chimney outlet.

4.4

turbine control room noise level (local control room) should not exceed within the 70dB (A).

4.5

at full load and stable operation of the gas turbine, the average noise level of its outer insulation cover at 120m should not exceed 60dB (A).

4.6

turbine working under special conditions, the allowable noise level by the purchaser and the contractor as otherwise agreed.

4.7

Purchaser technical documents shall clearly indicate the scope of the noise level limit value. Unless otherwise specified, the scope of the noise level limit value

It does not include transient noise sources and noise sources do not work jointly with the gas-turbine plant produced. If for multiple units running simultaneously,

Units Number of units should be clearly stated; if combined cycle plant installed in the plant for inside and outside plant installation shall state apparatus that contains other […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

Editions of GB/T 10491

EditionTitleRevisionStatus
GB/T 10491-2010Noise criteria and sound measurement procedures for aero-derivative gas turbines turnkey installationscurrent editionCurrent
GB/T 10491-1989Noise criteria and sound measurement procedures for aero-derivative gas turbines turnkey installationsprevious editionSuperseded

This page sells the current edition, GB/T 10491-2010. Earlier editions are listed for reference only.

How to Download GB/T 10491-2010

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 10491-2010

$145.00