Scope
GB 27898.4-2025 is the English-translated version of 固定消防给水设备 第4部分:消防气体顶压给水设备.
GB 27898.4-2025 is the Chinese national standard on fixed water supply equipment used for fire-protection - part 4: gas driven fixed water supply equipment used for fire-protection, in the field of environment and health protection, safety. It carries no /T suffix, which in the Chinese system means compliance is mandatory: a product or a practice within its scope has to meet it to be lawfully made, sold or carried out in China. It was issued on 31 October 2025 by the State Administration for Market Regulation; Standardization Administration of China, and takes effect on 1 November 2026. Classification: ICS 13.220.10, CCS C84. This page is published from the official record of the standard held by the Chinese standards administration: the identification, the dates, the classification and the issuing body are taken from there. The clause text, the tables and the numeric limits are in the document itself, which is delivered complete in English translation.
Document preview — GB 27898.4-2025
National Standard of the People's Republic of China
- ICS
- 13.220.10
- Classification
- C84
Issued by: State Administration for Market Regulation; Standardization Administration of China
Contents
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 4 Firefighting Gas Pressurized Water Supply Equipment
- 4.1 Product Classification
- 4.2 Model Numbering
- 5 Requirements
- 5.1 Basic Parameters
- 5.2 Equipment Composition and Components
- 5.3 Appearance and Marking
- 5.4 Control Functions
- 5.5 Water supply capacity
- 5.6 Continuous operation
- 5.7 Sealing performance
- 5.8 Water pressure strength
- 5.9 Operating noise
- 5.10 Pressure tank and accessories
- 5.11 Water pump unit
- 5.12 Top Pressure System
- 5.13 Pipeline valves and accessories
- 5.14 Control Instruments
- 5.15 Control Cabinet
- 6 General valves
- 6.1 Basic Test Requirements
- 6.2 Basic Parameter Check
- 6.3 Structural component inspection
- 6.4 Visual Marking Inspection
- 6.5 Control Function Test
- 6.6 Water Supply Capacity Test
- 6.7 Continuous Operation Test
- 6.8 Intermittent Operation Test
- 6.9 Sealing performance test
- 6.10 Hydrostatic Strength Test
- 6.11 Noise Measurement
- 6.12 Pressure Tank Inspection
- 6.13 Water pump unit test
- 6.14 Top pressure system test
- 6.15 Inspection of pipeline valves and accessories
- 6.16 Control Instrument Inspection
- 6.17 Control Cabinet Test
- 7 Inspection Rule
- 7.1 Inspection Classification and Items
- 7.2 Sampling Method
- 7.3 Judgment of Test Results
- 8 Signage and operating instructions
- 8.1 Signage
- 8.2 Operating Instructions
- 9 Packaging, transportation and storage
- 9.1 Packaging
- 9.2 Transportation
- 9.3 Storage
Foreword
This document complies with the provisions of GB/T 1.1-2020 "Standardization Work Guidelines Part
1.Structure and Drafting Rules of Standardization Documents". Drafting. This document is Part 4 of GB 27898 "Fixed Fire Water Supply Equipment". GB 27898 has the following parts published.
1.Firefighting Pneumatic Water Supply Equipment;
2.Automatic Constant Pressure Water Supply Equipment for Firefighting;
3.Fire-fighting pressurized and stabilized water supply equipment;
4.Firefighting Gas Pressurized Water Supply Equipment;
5.Firefighting Dual-Power Water Supply Equipment This document replaces GB 27898.4-2011 "Fixed Fire Water Supply Equipment Part
4.Fire Gas Pressurized Water Supply Equipment", and is consistent with... Compared with GB 27898.4-2011, apart from structural adjustments and editorial changes, the main technical changes are as follows:
---Added the terms "centralized pressure-reducing type fire-fighting gas pressure-pressurized water supply equipment", "decentralized pressure-reducing type fire-fighting gas pressure-pressurized water supply equipment", and "gas shut-off equipment". "device", "pressure water tank", "firefighting rated working pressure", "makeup water volume", "upper limit of stabilizing pressure", "lower limit of stabilizing pressure", "equipment maximum" "High working pressure" and "exhaust device" and their definitions (see Chapter 3);
---The terms "general-purpose fire-fighting gas pressure-pressurized water supply equipment" and "non-pressure-stabilized fire-fighting gas pressure-pressurized water supply equipment" and their definitions have been deleted (see [link]). (2011 edition,
---The definition of the term "fire-fighting gas pressurized water supply equipment" has been changed (see 3.1,.2011 edition of 3.1);
---Product classification and model designation have been changed (see Chapter 4, Chapter 4 of the.2011 edition);
---The requirements for "components" have been changed (see 5.2.2,.2011 version 5.2.2);
---The requirement for "regulated operation" has been changed (see 5.4.1,.2011 version 5.4.1);
1 Scope
GB 27898.4-2025 is the Chinese national standard on fixed water supply equipment used for fire-protection - part 4: gas driven fixed water supply equipment used for fire-protection, in the field of environment and health protection, safety. It carries no /T suffix, which in the Chinese system means compliance is mandatory: a product or a practice within its scope has to meet it to be lawfully made, sold or carried out in China. It was issued on 31 October 2025 by the State Administration for Market Regulation; Standardization Administration of China, and takes effect on 1 November 2026. Classification: ICS 13.220.10, CCS C84. This page is published from the official record of the standard held by the Chinese standards administration: the identification, the dates, the classification and the issuing body are taken from there. The clause text, the tables and the numeric limits are in the document itself, which is delivered complete in English translation.
This document specifies the classification, requirements, test methods, inspection rules, nameplates, and operating instructions for fire-fighting gas pressurized water supply equipment, as well as its packaging. Loading, transporting and storing. This document applies to fire-fighting gas pressurized water supply equipment.
2 Normative references
The contents of the following documents, through normative references within the text, constitute essential provisions of this document. Dated citations are not included. For references to documents, only the version corresponding to that date applies to this document; for undated references, the latest version (including all amendments) applies. This document.
GB/T 150 (All Parts) Pressure Vessels
GB/T 1226 General Pressure Gauges
GB/T 1227 Precision Pressure Gauges
GB/T 5099.1 Seamless steel gas cylinders - Part
1.Steel cylinders with a tensile strength of less than 1100 MPa after quenching and tempering.
GB/T 5100 Steel Welded Gas Cylinders
GB 5135.6 Automatic sprinkler systems - Part
3 Terms and Definitions
The following terms and definitions apply to this document.
3.1 In fire-fighting operation, compressed gas is depressurized and then injected into the pressure water tank, displacing the fire-fighting water stored in the tank, and filling it with the rated water within a specified time. Water supply equipment that supplies fire-fighting water to the fire-fighting pipeline network under working pressure.
Note. It is usually composed of components such as a pressure tank and accessories, a pressure stabilizing pump set, a top pressure system, pipeline valves and accessories, measuring and control instruments, and a control cabinet.
3.2 gas driven system In fire-fighting gas pressurized water supply equipment, the general term refers to the components related to the storage, monitoring, pressure reduction, and release of compressed gas.
3.3 The compressed gas in the top-pressure system is collected from the gas storage cylinder group and then concentrated and depressurized before being filled into the pressure water tank. This is a fire-fighting gas top-pressure water supply equipment.
6 General valves
GB/T 8979 Pure Nitrogen, High-Purity Nitrogen and Ultra-Purity Nitrogen
GB/T 9969 General Rules for Instructions for Use of Industrial Products
GB 25972-2024 Gas Fire Suppression Systems and Components
GB 27898.1-2011 Fixed fire-fighting water supply equipment - Part
1.Fire-fighting pneumatic water supply equipment XF61-2010 General Technical Specifications for Drive and Control Devices of Fixed Fire Extinguishing Systems
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 16 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 1226General pressure gauge
- GB/T 1227Accurate pressure gauge
- GB 5135.6Automatic sprinkler systems - Part 6: Conventional valves
- GB/T 8979Pure nitrogen, high purity nitrogen and ultra pure nitrogen
- GB/T 9969General principles for preparation of instructions for use of industrial products
- GB 25972-2024Gas fire extinguishing systems and components
GB/T 150 · GB/T 5099.1 · GB/T 5100
Similar standards
Editions of GB 27898.4
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB 27898.4-2025 | Fixed water supply equipment used for fire-protection - Part 4: Gas driven fixed water supply equipment used for fire-protection | current edition | Current |
| GB 27898.4-2011 | Fixed water supply equipment used for fire-protection - Part 4: Gas driven fixed water supply equipment used for fire-protection | previous edition | Superseded |
This page sells the current edition, GB 27898.4-2025. Earlier editions are listed for reference only.
How to Buy GB 27898.4-2025
- 1Add to cart. Click the "Buy GB 27898.4-2025" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 25972-2024 — Gas fire extinguishing systems and components
GB 27898.1-2011 — Fixed water supply equipment used for fire-protection - Part 1: Gas pressure fixed water supply equipment used for fire-protection
GB 5135.6-2018 — Automatic sprinkler systems - Part 6: Conventional valves
Secure payment via Stripe
Payments accepted
GB 27898.4-2025
$275.00