Valid

GB 26875.9-2026Remote-monitoring system of urban fire protection - Part 9: User information transmission device (English PDF)

城市消防远程监控系统 第9部分:用户信息传输装置

Open the GB 26875.9-2026 preview as PDF

Preview — first pages of GB 26875.9-2026 (full document: 19 pages)

This is a limited preview

Buy now to download the full PDF (19 pages)

Issued by

State Administration for Market Regulation; Standardization Administration of China

Level / Type

National · Mandatory

Issue date

February 27, 2026

Implementation date

March 1, 2027

Scope

GB 26875.9-2026 is the English-translated version of 城市消防远程监控系统 第9部分:用户信息传输装置.

GB 26875.9-2026 is the Chinese national standard on remote-monitoring system of urban fire protection - part 9: user information transmission device, in the field of environment and health protection, safety. It carries no /T suffix, which in the Chinese system means compliance is mandatory: a product or a practice within its scope has to meet it to be lawfully made, sold or carried out in China. It was issued on 27 February 2026 by the State Administration for Market Regulation; Standardization Administration of China, and takes effect on 1 March 2027. Classification: ICS 13.220.20, CCS C81. This page is published from the official record of the standard held by the Chinese standards administration: the identification, the dates, the classification and the issuing body are taken from there. The clause text, the tables and the numeric limits are in the document itself, which is delivered complete in English translation.

Document preview — GB 26875.9-2026

National Standard of the People's Republic of China

ICS
13.220.20
Classification
C81

Issued by: State Administration for Market Regulation; Standardization Administration of China

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions
  • 4 Classification
  • 5 Technical Requirements
  • 5.1 Appearance
  • 5.2 Main Components
  • 5.3 Receiving and transmitting information on the operational status of fire protection facilities
  • 5.4 Inspection
  • 5.5 Self-inspection
  • 5.6 Resuming interrupted downloads
  • 5.7 Time synchronization reception
  • 5.8 Machine fault alarm
  • 5.9 Manual Alarm
  • 5.10 Response to Check-in
  • 5.11 Power Supply
  • 5.12 Power Parameter Fluctuation Performance
  • 5.13 Insulation performance
  • 5.14 Leakage Current
  • 5.15 Electrical strength performance
  • 5.16 Electromagnetic compatibility performance
  • 5.17 Climate and Environmental Tolerance
  • 5.18 Mechanical environmental tolerance
  • 5.19 Software Requirements
  • 5.20 Operational Level
  • 6.1 General Rules
  • 6.2 Inspection of appearance and main components
  • 6.3 Test on Receiving and Transmitting Fire Protection Facility Operation Status Information
  • 6.4 Inspection Test
  • 6.5 Self-test
  • 6.6 Resuming Downloads After Breakpoints Test
  • 6.7 Time synchronization and reception test
  • 6.8 Machine fault alarm test
  • 6.9 Manual Alarm Test
  • 6.10 On-duty inspection response test
  • 6.11 Power Supply Test
  • 6.12 Power Parameter Fluctuation Performance Test
  • 6.13 Insulation Resistance Test
  • 6.14 Leakage Current Test
  • 6.15 Electrical strength test
  • 6.16 Radio Frequency Electromagnetic Field Radiation Immunity Test
  • 6.17 Conducted Interference Immunity Test Based on Radio Frequency Field Induction
  • 6.18 Electrostatic Discharge Immunity Test
  • 6.19 Electrical Fast Transient/Bulk Immunity Test
  • 6.20 Surge (Impulse) Immunity Test
  • 6.21 Power Transient Test
  • 6.22 Immunity Tests for Voltage Sags, Short Interruptions, and Voltage Variations
  • 6.23 Low Temperature (Operation) Test
  • 6.24 Constant Temperature and Humidity (Operation) Test
  • 6.25 Constant Damp Heat (Durability) Test
  • 6.26 Vibration (Sine) (Running) Test
  • 6.27 Crash Test
  • 7 Inspection Rule
  • 7.1 Factory Inspection
  • 7.2 Type Testing
  • 8 Markings and Instruction Manual
  • 8.1 Product Marking
  • 8.2 Quality Inspection Mark
  • 8.3 Instruction Manual
  • 9 User Information Transmission Device

Foreword

This document complies with the provisions of GB/T 1.1-2020 "Standardization Work Guidelines Part

1.Structure and Drafting Rules of Standardization Documents". Drafting. This document is Part 9 of GB (/T) 26875 "Urban Fire Remote Monitoring System". GB (/T) 26875 has the following publications. part.

1.General Technical Requirements;

2.Functional Requirements for Communication Service Software;

3.Alarm Transmission Network Communication Protocol;

4.Basic Data Items;

5.Software Functional Requirements;

6.Functional Requirements for Information Management Software;

7.Functional Requirements for Fire Protection Facility Maintenance and Management Software;

8.Monitoring Center External Data Exchange Protocol;

9.User Information Transmission Device;

10.Requirements for fire protection facility information collection devices and interfaces. This document supersedes GB 26875.1-2011 "Urban Fire Remote Monitoring System Part

1.User Information Transmission Device" and is consistent with... Compared with GB 26875.1-2011, apart from structural adjustments and editorial changes, the main technical changes are as follows:

a) Added "Categories" (see Chapter 4);

1 Scope

GB 26875.9-2026 is the Chinese national standard on remote-monitoring system of urban fire protection - part 9: user information transmission device, in the field of environment and health protection, safety. It carries no /T suffix, which in the Chinese system means compliance is mandatory: a product or a practice within its scope has to meet it to be lawfully made, sold or carried out in China. It was issued on 27 February 2026 by the State Administration for Market Regulation; Standardization Administration of China, and takes effect on 1 March 2027. Classification: ICS 13.220.20, CCS C81. This page is published from the official record of the standard held by the Chinese standards administration: the identification, the dates, the classification and the issuing body are taken from there. The clause text, the tables and the numeric limits are in the document itself, which is delivered complete in English translation.

This document specifies the classification, technical requirements, inspection rules, and markings for user information transmission devices in urban fire remote monitoring systems. The instruction manual describes the corresponding test methods. This document applies to the design of user information transmission devices for urban fire remote monitoring systems installed in general industrial and civil buildings. Design, manufacturing and inspection.

2 Normative references

The contents of the following documents, through normative references within the text, constitute essential provisions of this document. Dated citations are not included. For references to documents, only the version corresponding to that date applies to this document; for undated references, the latest version (including all amendments) applies. This document.

GB/T 9969 General Rules for Instructions for Use of Industrial Products

GB 12978 Inspection Rules for Fire Protection Electronic Products

GB/T 16838 Environmental testing methods and severity levels for fire protection electronic products

GB/T 17626.2 Electromagnetic compatibility testing and measurement techniques - Electrostatic discharge immunity test

GB/T 17626.3 Electromagnetic compatibility testing and measurement techniques - Part

3 Terms and Definitions

The terms and definitions defined in GB/T 26875.1 apply to this document.

4.Classification User information transmission devices (hereinafter referred to as "transmission devices") are classified according to their functions as follows:

a) General-purpose type (with local information display and query control functions);

b) Gateway type (does not have local information display and query control functions).

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 19 pages — is available in the English PDF.

Referenced standards

Similar standards

Editions of GB 26875.9

EditionTitleRevisionStatus
GB 26875.9-2026Remote-monitoring system of urban fire protection - Part 9: User information transmission devicecurrent editionCurrent
GB 26875.1-2011Remote-monitoring system of urban fire protection - Part 1: User information transmission devicemerged into this editionSuperseded

This page sells the current edition, GB 26875.9-2026. Earlier editions are listed for reference only.

How to Buy GB 26875.9-2026

  1. 1Add to cart. Click the "Buy GB 26875.9-2026" button on this page. You can add more standards before checkout.
  2. 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
  3. 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
  4. 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
19 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB 26875.9-2026

$335.00

$285.00for partners