GB 21556-2008 is the Chinese national standard on general safety technique requirnent of locks, in the field of domestic and commercial equipment, entertainment, sport. It carries no /T suffix, which in the Chinese system means compliance is mandatory: a product or a practice within its scope has to meet it to be lawfully made, sold or carried out in China. It was issued on 24 March 2008 by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China, and has been in force since 1 March 2009. Classification: ICS 97.180, CCS Y73. This page is published from the official record of the standard held by the Chinese standards administration: the identification, the dates, the classification and the issuing body are taken from there. The clause text, the tables and the numeric limits are in the document itself, which is delivered complete in English translation.
Document preview — GB 21556-2008
National Standard of the People's Republic of China
- ICS
- 97.180
- Classification
- Y73
Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China
Contents
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 4 Requirements
- 4.1 Padlock marbles
- 4.1.5 Specifications of not less than 35mm anti-lock press
- 4.4 exterior door locks
- 4.5 Mortise locks
- 4.6 Blade mortise lock
- 4.7 Ball locks
- 4.8 Fire Door
- 5 Test methods
- 5.1 Test Billiard padlock
- 5.3 Test bicycle lock
- 5.5 Mortise Lock Test
- 5.6 Test blade mortise lock
- 5.7 ball locks test
- 5.8 Fire door test
- 5.9 mechanical anti-theft lock test
- 6 Inspection Rules Testing apparatus and equipment Appendix A (normative) standard used in the detection means, the tool
- 10 Electronic locks
- 22 Power Door Lock Test 24 5.11
Foreword
Chapter 4 of this standard are mandatory, others are recommended. This standard adopts the technical content of foreign advanced standards, the degree of consistency. Marble furniture locks and DIN68852-2004 "furniture locks requirements, testing" non-equivalent; Bike lock and JISD9456-1994 "bike lock," the non-equivalent; Ball locks and ANSI/BHMAA156.2-2003 "ball locks, door locks and preloaded bolt," the degree of non-conformity Equivalent; Mortise locks, mortise lock blade and JISA1510-1.2001 "Test methods for metallic building door fittings - Part 1. Lock "non-equivalent; Electric door lock controllers in part by reference to GB 14536.1-1998 "household and similar use automatic controllers - Part 1. General requirements "and GB 14536.13-1996" household and similar use Particular requirements for electrical controls the electric door locks. " Appendix A of this standard is a normative appendix. The standard proposed by China National Light Industry Council. This standard by the National Standardization Technical Committee Hardware daily hardware sub-technical committee. This standard was drafted. national daily Metal Products Quality Supervision and Inspection Center, Shanghai use Suochang, Guli Security Products Limited, Zhejiang Jiang Zhongli Group Co., powerful Group Co., Ltd., Shanghai emerging Suochang, Zhejiang Tianyu Industrial Co., Ltd., Shandong double-Electronic Lock Co. shares Limited copies. The main drafters of this standard. Wang Zhenmin, Liu Rongjian, Bizhi Tao, Zhanxian Guang, Pan taught Ting, Wen Hui positive, forest development, Zhang Lijun. General technical conditions of safety locks
1 Scope
GB 21556-2008 is the Chinese national standard on general safety technique requirnent of locks, in the field of domestic and commercial equipment, entertainment, sport. It carries no /T suffix, which in the Chinese system means compliance is mandatory: a product or a practice within its scope has to meet it to be lawfully made, sold or carried out in China. It was issued on 24 March 2008 by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China, and has been in force since 1 March 2009. Classification: ICS 97.180, CCS Y73. This page is published from the official record of the standard held by the Chinese standards administration: the identification, the dates, the classification and the issuing body are taken from there. The clause text, the tables and the numeric limits are in the document itself, which is delivered complete in English translation.
This standard specifies the terms and definitions locks, requirements, test methods, inspection rules. This standard applies to padlock ball, billiard furniture locks, bicycle locks, exterior door locks, Mortise locks, mortise lock blade, spherical shutter Locks, fire door locks, mechanical anti-theft locks, electronic locks, electric door locks 1). 1) Rated DC voltage not exceeding 440V, AC not more than 660V, rated current not exceeding 63A locks. May refer to other similar locks. This standard does not apply to industrial locks and special locks.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 2829 periodic inspection Sampling procedures and tables (suitable for process stability test)
GB 4208-1993 housing protection (IP Code) (eqv IEC 529. 1989) Part 1
GB 4706.1-2005 Safety of household and similar electrical appliances. General requirements (
IEC 60335-1.2004 (Ed4.1), IDT) Resistance test methods
GB/T 7633 Door and shutter (eqv ISO 3008. 1976) Part 1
GB 14536.1-1998 household and similar electrical controls. General requirements (idt
IEC 730-1.1993) Particular requirements
GB 14536.13-1996 household and similar electrical automatic controller electrically operated door locks (idt IEC 730-2-12. 1993)
GB/T 15729 Torque wrench - General requirements
GB/T 17626.2 Electromagnetic compatibility Testing and measurement techniques - Electrostatic discharge immunity test ( GB/T 17626.2-2006, IEC 61000-4-2.2001, IDT)
GB/T 17626.3 electromagnetic compatibility test and measurement technology RFEMS test ( GB/T 17626.3- 2006, IEC 61000-4-3.2001, IDT)
GB/T 17626.4 Electromagnetic compatibility Testing and measurement techniques - Electrical fast transient burst immunity test ( GB/T 17626.4- 1998, idt IEC 61000-4-4.1995)
GB/T 17626.11 Electromagnetic compatibility Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests ( GB/T 17626.11-1999, idt IEC 61000-4-11.1995)
3 Terms and Definitions
The following terms and definitions apply to this standard.
3.1 Technical performance indicators and vandal ability level difference divided levels.
3.2 Tooth groove having a spoon or information and information carriers, for open and close the lock parts.
3.3 Arranged into a group or several groups of high and low teeth on a key.
3.4 In the batch key Tooth mutually different totals.
3.5 Another key itself can use the lock to open the phenomenon.
3.6 Lock structure, with anti-foreign body open devices.
3.6.1 Poke resist is within a predetermined period of time, the ability to cause the lock to be opened.
3.6.2 Resist within a predetermined period of time is bad drill, resulting in the ability to lock is turned on.
3.6.3 Resist within a predetermined period of time to be amputated parts, resulting in the ability to lock function failure.
3.6.4 Against being forced open within the stipulated time, resulting in the ability to lock function failure.
3.6.5 Resistant locks professional and technical personnel using special tools or methods to open the lock capability.
3.7 We have assembled cylinder and other parts of the components.
3.8 Has a key slot, direct action can deliver key parts.
4.1 Padlock marbles
4.1.1 Key spend a different number of teeth should be consistent with Table 1.
4.1.2 Mutual opening rate should be consistent with Table 1.
4.1.3 Anti-lock structure allocated safety device shall comply with the provisions in Table 1. Table
1 Key flowers and different numbers of teeth mutual opening rate Product Specifications/mm 30 35 40 45 50 60
75 Tooth number of different keys/species >= 300 1500 1800 8000 15000 18000 Mutual opening rate /% <= 0.345 0.204 0.163
0.122 Anti-lock structure allocated safety device/item >= 1
4.1.4 Shackle tensile strength should meet the provisions of Table 2. Table
4.1.5 Specifications of not less than 35mm anti-lock press
5.1.5 Test tap open, the lock can not be opened.
4.1.6 fall from a height of 1.8m locks still work, with no broken shackle and lock body cracking.
4.1.7 life should be shown in Table 3. Table 3 locks life Product Specifications/mm 30 35 40 45 50 60
75 Frequency/time >= 7000 9000
4.2 marble furniture locks
4.2.1 Key spend a different number of teeth should be consistent with Table 4.
4.2.2 Mutual opening rate should be consistent with Table 4. Table
4 Key flowers and different numbers of teeth mutual opening rate Lock head diameter/mm < 20 >=
20 Key Tooth/month 4545 Tooth number of different keys/species >= 200 750 500 2500 Mutual opening rate /% <= 0.575 0.612 0.327 0.245
4.2.3 lock structure should have at least one anti-dial safety device.
4.2.4 latch extension of not less than 6mm.
4.2.5 lock is fixedly connected static tension. lock diameter not less than 20mm, bear after 200N, no loose; lock diameter of not more than 20mm, After the bear 140N, no loose.
4.2.6 fixed connection torque lock. lock diameter not less than 20mm, bear 2.60N · m after, no loose; the lock is not greater than the diameter 20mm, after bear 1.80N · m, without loosening.
4.2.7 Cylinder toggle subjecting after 0.70N · m of torque, can still be used normally.
4.5 Mortise locks
4.5.1 Key spend a different number of teeth should be consistent with the provisions in Table 10.
4.5.2 Mutual opening rate shall comply with the provisions in Table 10. Table
10 Number of different keys Tooth and mutual opening rate Project Name Single-row multi-row marbles marbles Tooth number of different keys/species >= 6000 50000 Mutual opening rate /% <= 0.204 0.050
4.5.3 lock structure should have at least one anti-dial safety device.
4.5.4 extends the length of the bolt should be consistent with the provisions of Table 11. Table 11 extends the length of the bolt project name Double tongue Side oblique tongue tongue, knuckle Double tongue (aluminum, steel doors) double tongue (steel door) single tongue Extended length/mm >= 11 12.5 10 9 12 NOTE. Install the center distance is not more than 18mm, tongue protruding length not less than 8mm.
4.5.5 the tongue withstand 1000N axial static load, the still normal use.
4.5.6 the tongue withstand 1500N static lateral after still normal use.
4.5.7 knuckle after the bear 800N static tension, it can still be used normally.
4.5.8 oblique tongue withstand 1000N static lateral after still normal use.
4.5.9 lock with the lock body screwed screwed smoothly, when the lock is screwed into the lock body to withstand 500N static tension when the thread does not slip teeth.
4.5.10 Handle after withstand 5N · m of torque, can still be used normally.
4.5.11 Handle withstand 1000N after radial static load, it can still be used normally.
4.5.12 Handle withstand 1000N axial static tension after still normal use.
4.5.13 the tongue, knuckle life of less than 50,000.
4.6 Blade mortise lock
4.6.1 each key of the lock tooth number of flowers should be less than 72 species (including different geometries).
4.6.2 mutual opening of not more than 0.051%.
4.6.3 factory, each box with no Tooth key.
4.6.4 extends the length of the bolt should be consistent with the provisions in Table 12. Table 12 extends the length of the bolt Project name of a file to open Second gear Open The first tranche of the second tranche Extended length/mm >= The tongue 12816 Oblique tongue 10
4.6.5 the tongue withstand 1000N axial static load, the still normal use.
4.6.6 the tongue withstand 1500N static lateral after still normal use.
4.6.7 oblique tongue withstand 1000N static lateral after, still normal use.
4.6.8 Handle after withstand 5N · m of torque, can still be used normally.
4.6.9 Handle withstand 1000N after radial static load, it can still be used normally.
4.6.10 Handle withstand 1000N axial static tension after still normal use.
4.6.11 the tongue life. 30,000 times less than a single open, double open no less than 20,000 times.
4.6.12 oblique tongue life no less than 70,000 times.
4.7 Ball locks
4.7.1 Key spend a different number of teeth should be consistent with the provisions of Table 13. Table 13 key units of different species spend several teeth Billiard ball lock lock blade Single-row multi-row marbles marbles have no differential differential >=6000 >=100000 >=500 >=6000
4.7.2 Mutual opening rate shall comply with the provisions in Table 14. Table mutual opening rate of 14% level Billiard ball lock lock blade Single-row multi-row marbles marbles have no differential differential A <=0.082 <=0.010 - <=
0.082 B <=0.204 <=0.020 <=0.326 <=0.204
4.7.3 extends the length of the bolt should meet the requirements given in Table 15. Table 15 projecting bolt length in millimeters Level spherical lock in lock Pull glove lock Side oblique tongue tongue A >=12 B >=11 >=25 >=25 >=11
4.7.4 Pinball lock lock structure should have at least one anti-dial safety device. Fixed lock bolt should have anti-saw safety device.
4.7.5 insured the tongue (ie Insurance tongue), tongue when pressed to the locked position, the latch extension of not less than 6.4mm, the insurance is not a small column projecting To 5.6mm.
4.7.6 Handle Table 16 (locked state and non-locked state) obedient, then counterclockwise torque test, can still be used normally. Handle Table
16 Nm of torque units level Locked state is not locked state Spherical handle curved handle spherical handle curved handle A >=17 >=20 >=14 >=17 B >=12 >=14 >=10 >=14
4.7.7 Handle static axial tension. A level after withstand 1400N, 1000N bear after class B, can still be used normally.
4.7.8 Handle radial static load. A class after withstand 1150N, grade B bear 800N later, still normal use.
4.7.9 static lateral tongue. A level in the ball lock withstand 2700N, grade B bear after 1500N, still normal use; fixed lock After the A level after withstand 1900N, B grade withstand 1400N, it can still be used normally. After
4.7.10 bolt insurance, axial static load. After locking in Class A ball bear 350N, grade B bear 300N, still normal use; fixed After locking in Class A bear 500N, B grade withstand 350N, it can still be used normally.
4.7.11 fixed lock knob to withstand 500N static tension after still normal use.
4.7.12 fixed locking screw to withstand 1500N static tension after still normal use.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 35 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 2829Sampling procedures and tables for periodic inspection by attributes
- GB/T 17626.11-1999Electromagnetic compatibility - Testing and measurement techniques - Part 11: Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
GB 4208-1993 · IEC 529 · GB 4706.1-2005 · IEC 60335 · GB/T 7633 · ISO 3008 · GB 14536.1-1998 · IEC 730 · GB 14536.13-1996 · GB/T 15729 · GB/T 17626.2-2006 · IEC 61000 · GB/T 17626.3 · GB/T 17626.4 · GB 50045-1995
Similar standards
Editions of GB 21556
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB 21556-2008 | General safety technique requirnent of locks | current edition | Current |
This page sells the current edition, GB 21556-2008. Earlier editions are listed for reference only.
How to Buy GB 21556-2008
- 1Add to cart. Click the "Buy GB 21556-2008" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 17626.39-2023 — Electromagnetic compatibility - Testing and measurement techniques - Part 39: Radiated fields in close proximity - Immunity test
GB/T 2829-2025 — Sampling procedures and tables for periodic inspection by attributes
GB/T 28290-2012 — Methods for determination of surface chromium on electrolytic tinplate
Secure payment via Stripe
Payments accepted
GB 21556-2008
$510.00