GB 18279-2023Sterilization of health-care products—Ethylene oxide—Requirements for the development,validation and routine control of a sterilization process for medical devices (English PDF)
医疗保健产品灭菌 环氧乙烷 医疗器械灭菌过程的开发、确认和常规控制要求
Also coversGB18279-2023
This is a limited preview
Buy now to download the full PDF
Need quotation for your management?
Get a formal quotation for GB 18279-2023 in 30 minutes.
Issued by
State Administration for Market Regulation; Standardization Administration of China
Level / Type
National · Mandatory
Issue date
September 8, 2023
Implementation date
October 1, 2026
Scope
GB 18279-2023 is the English-translated version of 医疗保健产品灭菌 环氧乙烷 医疗器械灭菌过程的开发、确认和常规控制要求.
GB 18279-2023 — This document specifies the development, validation and routine control requirements for the ethylene oxide sterilization process during the manufacturing process of medical device products. It is applicable to medical devices sterilized by ethylene oxide.
Found what you need?
Document preview — GB 18279-2023
National Standard of the People's Republic of China
- ICS
- 11.080.01
- Classification
- C47
Issued by: State Administration for Market Regulation; Standardization Administration of China
Contents
- Foreword...3
- Introduction...6
- 1 Scope...8
- 2 Normative references...9
- 3 Terms and definitions...10
- 4 Quality management system...19
- 5 Characteristics of sterilizing agents...20
- 6 Process and device characteristics...21
- 7 Product definition...23
- 8 Process definition...25
- 9 Validation...26
- 10 Routine monitoring and control...33
- 11 Sterilization release of products...34
- 12 Maintenance of effectiveness of sterilization process...35
Foreword
This document was drafted in accordance with the rules given in GB/T 1.1-2020
"Directives for standardization - Part 1.Rules for the structure and drafting of
standardizing documents".
This document replaces GB 18279.1-2015 "Sterilization of health care products -
Ethylene oxide - Part 1.Requirements for development, validation and routine control
of a sterilization process for medical devices" and GB/T 18279.2-2015 "Sterilization of
health care products - Part 2.Guidance on the application of GB 18279.1". In addition
to structural adjustments and editorial changes, the main technical changes are as
follows.
- Added instructions for the application of this document in health care facility (see
1.1 of this Edition);
- Added some terms (see 3.10, 3.38, 3.43, 3.57 of this Edition);
- Deleted some terms (see 3.19 of GB 18279.1-2015 and 3.1 of GB/T 18279.2-2015);
- Modified the requirements for the quality management system (see 4.1, 4.2, 4.3 of
this Edition; 4.1, 4.2, 4.3 of GB 18279.1-2015);
- Modified the requirements for sterilizing agent (see 5.1, 5.2, 5.5 of this Edition;
5.1, 5.4 of GB 18279.1-2015);
- Added an overview of process and equipment characteristics (see 6.1 of this
Edition);
- Modified the requirements for process characteristics (see 6.2 of this Edition; 6.1
of GB 18279.1-2015);
- Added the purpose and content of product definition (see 7.1.1, 7.1.5 of this
Edition);
- Deleted the requirements for the most difficult to sterilize location (see 7.1.3 of GB
18279.1-2015);
- Added the purpose of process definition (see 8.1 of this Edition);
- Added general rules for confirmation (see 9.1 of this Edition);
- Added the requirements for installation qualification (see 9.2.1.3, 9.2.2.3, 9.2.2.4,
9.2.2.6 of this Edition);
- Added performance qualification requirements (see 9.4.1.1, 9.4.1.5, 9.4.1.6 of this
Edition);
- Changed the requirements for performance qualification (see 9.4.1.8 of this Edition;
9.3 of GB 18279.1-2015);
- Added requirements for microbial performance qualification (see 9.4.2.5, 9.4.2.6,
9.4.3.2 of this Edition);
- Added parameters that shall be specified in the validation report (see 9.5.4 of this
Edition);
- Added the objectives and requirements of routine monitoring (see 10.1, 10.2, 10.3
of this Edition);
- Changed the requirements for product release (see 11.2, 11.3, 11.4 of this Edition;
Chapter 11 of GB 18279.1-2015);
- Changed the requalification requirements (see 12.3.1, 12.3.3 of this Edition; 12.3
of GB 18279.1-2015);
- Added requirements for change assessment (see 12.4.2, 12.4.6 of this Edition);
- Added the content of equivalence evaluation (see 12.5 of this Edition);
- Deleted the description of the procedures and calculation methods for the biological
indicator/bioburden method (see A.2 and A.3 of GB 18279.1-2015);
- Changed the procedure of the overkill approach (see B.2 of this Edition; B.2 of GB
18279.1-2015);
- Changed the number of sensors and biological indicators (see Table C.1 and Table
C.3 of this Edition; Table C.1 and Table C.3 of GB 18279.1-2015);
- Added content related to single batch release (see Annex E of this Edition).
The modification of this document adopted ISO 11135.2014 "Sterilization of health-
care products - Ethylene oxide - Requirements for the development, validation and
routine control of a sterilization process for medical devices".
The technical differences between this document and ISO 11135.2014 and their reasons
are as follows.
- Changed the description of the requirements for health care facility in the scope
(see 1.1) to avoid conflicts between the mandatory requirements of the standard
and the requirements of the regulations;
- Deleted the term "medical device" (see 3.21 of ISO 11135.2014) to avoid conflict
with Chinese regulations;
- Changed the terminology of "spore-log-reduction" (see 3.41 of this Edition) to
make it easier to understand;
- Deleted the exception for analytical (if used) process variable control (see 6.2.5 of
ISO 11135.2014) to standardize the process control requirements;
- Deleted the specification of the method for proving that the bioburden resistance is
less than the resistance of the biological indicator in the overkill approach (see
B.1.4 of ISO 11135.2014) to avoid limiting the application of the standard;
- Changed the references to other international standards in 4.1.2, 4.3.1, 4.3.2, 4.3.3,
4.4, 7.3.2, 8.9, 11.3, 11.4, and E.1 to notes to suit China's national conditions.
The following editorial changes were made to this document.
- The amendments to ISO 11135.2014/Amd.1.2018 were incorporated. The outer
- Deleted the note in 1.2.2 to adapt to China's national conditions;
- Used YY/T 0287-2017 to replace ISO 13485.2016 to adapt to China's national
conditions;
- Moved the note referring to Annex E in 11.4 into the main text to be consistent with
the normative Annex E;
- Simplified the description of A.2 to make the standard terms clearer;
- Added management standards for health care institutions for reference in applicable
guidelines (see note to D.4.2.2).
- Added two notes in D.5.5.1 to better describe the combustion and explosion of
ethylene oxide;
- Changed the interpretation of D.12.5 to refer to YY/T 1268 to make the standard
content easier to understand.
Attention is drawn to the possibility that some of the elements of this document may be
the subject of patent rights. The issuing authority shall not be held responsible for
identifying any or all such patent rights.
This document was proposed by and shall be under the jurisdiction of State
Administration for Market Regulation.
Versions of standard substituted by this document are.
- It was first published in 2000 as GB 18279-2000;
- It was first revised in 2015 as GB 18279.1-2015 and GB/T 18279.2-2015;
This is the second revision.
1 Scope
This document specifies the development, validation and routine control requirements
for the ethylene oxide sterilization process during the manufacturing process of medical
device products. It is applicable to medical devices sterilized by ethylene oxide.
2 Normative references
The following referenced documents are indispensable for the application of this
document. For dated references, only the edition cited applies. For undated references,
the latest edition of the referenced document (including any amendments) applies.
GB 18281.1-2015, Sterilization of health care products - Biological indicators - Part
1 General requirements (ISO 11138-1.2006, IDT)
GB 18281.2-2015, Sterilization of health care products - Biological indicators - Part
2 Biological indicators for ethylene oxide sterilization processes (ISO 11138-
2.2006, IDT)
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
A test system containing live microorganisms that has a specific resistance to a specified
sterilization process.
A test system that exhibits changes in one or more predetermined process variables
based on chemical or physical changes caused by exposure to a sterilization process.
4 Quality management system
The responsibilities and authorities for implementing and meeting the
requirements of this document shall be specified. The responsibilities may be assigned
to competent personnel in accordance with the applicable provisions of YY/T 0287-
2017.
Where the requirements of this document are undertaken by more than one
organization with separate quality management systems, the responsibilities and
authorities of each party shall be specified.
Calibration procedures for all equipment (including test instruments) used to meet
the requirements of this document shall be specified.
5 Characteristics of sterilizing agents
If ethylene oxide outside the recognized composition range is used or a new diluent is
used, data on microbiological effectiveness shall be developed.
The effects of ethylene oxide on most materials used to manufacture medical devices
have been thoroughly documented. This documentation is valuable in the design and
development of medical devices that are sterilized using ethylene oxide. This document
does not require specific studies on the effects of ethylene oxide on materials, but does
require studies on the effects of ethylene oxide on products (see Chapter 7).
6 Process and device characteristics
a) identification of the necessary stages of the ethylene oxide sterilization process;
b) identification of the process variables at each stage;
c) documentation of the process variables.
7 Product definition
The sterilization process shall be defined using the process parameters and
tolerances that have been identified as having the greatest impact on the
product/package. Confirm that the product and its packaging meet the specified safety,
quality and performance requirements.
The medical device manufacturer shall document the results of the product definition.
8 Process definition
The suitability of process challenge devices for process definition, validation, and
routine monitoring and control shall be determined. The challenge to the sterilization
process from the process challenge device shall be greater than or equal to the challenge
of the natural bioburden at the most difficult location to sterilize in the product.
9 Validation
For the equipment used in sterilization process, only one installation qualification and
one operational qualification may be carried out for the designated equipment.
qualification to prove that the sterilization process meets the specified acceptance
criteria and can achieve the sterility assurance level required by the product.
At least three consecutive, planned qualification runs shall be included. These runs shall
meet all specified acceptance criteria.
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.
Referenced standards
Normative references
GB 18281.1-2015
Cited by
- GB/T 25304-2025Non-vascular self-expanding metallic stent system
- GB/Z 44877-2024Sterilization of medical devices - Guidance on using parametric release for ethylene oxide sterilization process
- YY 0861-2024Ophthalmic optics - Ophthalmic viscosurgical devices
- YY/T 1553-2017Cardiovascular implants-Cardiac occluder
- YY/T 1571-2017Tissue engineering medical device products—Sodium hyaluronate
- YY 0604-2016Cardiopulmonary bypass systems - Blood-gas exchangers (oxygenators)
How to Download GB 18279-2023
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 18279.1-2015 — Sterilization of health care products—Ethylene oxide—Part 1: Requirements for development,validation and routine control of a sterilization process for medical devices
GB 11118-2026 — Hydraulic fluids (L-HL, L-HM, L-HV, L-HS and L-HG type)
GB 11557-2026 — Provisions for protecting drivers from injury by the steering mechanism of motor vehicles
Secure payment via Stripe
Payments accepted
GB 18279-2023
$880.00