YY 0604-2016Cardiopulmonary bypass systems - Blood-gas exchangers (oxygenators) (English PDF)

心肺转流系统血气交换器(氧合器)

Preview PDF

This is a limited preview

Buy now to download the full PDF (18 pages)

Need quotation for your management?

Get a formal quotation for YY 0604-2016 in 30 minutes.

Issued by

NMPA

Level / Type

Industry · Mandatory

Issue date

March 23, 2016

Implementation date

January 1, 2018

Scope

YY 0604-2016 is the English-translated version of 心肺转流系统血气交换器(氧合器).

YY 0604-2016 is the Chinese pharmaceutical industry standard for the blood-gas exchanger, the oxygenator of a sterile single-use cardiopulmonary bypass system, which oxygenates the blood and removes carbon dioxide from it in place of or in support of the lung.

It sets the requirements for the device, covering the gas transfer performance and the pressure drop, the priming volume and the blood path, the leak tightness at the working pressure, the freedom from particles, the materials and their biological evaluation and sterility.

It applies as well to the heat exchanger where that is part of the oxygenator. Issued on 23 March 2016, it applies from 1 January 2018.

Found what you need?

Document preview — YY 0604-2016

National Standard of the People's Republic of China

ICS
11.040.40
Classification
C 45
Replacing
YY 0604-2007

Issued by: National Medical Products Administration of the People's Republic of China

Contents

  • Preface
  • Introduction
  • 1 Scope
  • 2 normative reference document
  • 3 Terms and definitions
  • 5 requirements
  • 5.1 Biological properties
  • 5.2 Physical characteristics
  • 5.3 Performance characteristics
  • 5.4 Chemical properties
  • 5.5 Valid
  • 6 Test method
  • 6.1 Overview
  • 6.2 Biological performance test
  • 6.3 Physical performance test
  • 6.4 Performance characteristics test
  • 6.5 Chemical properties test
  • 6.6 Validity test
  • 7 Information provided by the manufacturer
  • 7.1 Information on Oxygenator
  • 7.2 Description of the label on the packaging
  • 7.3 User's Manual
  • 7.4 Special note in random file
  • 8 Packing
  • Appendix A (informative) The technical differences between this and ISO 7199.:2009 and its causes Reference

Foreword

This standard is drafted in accordance with the rules given in GB/T 1.1-2009.

This standard adopts the re-drafting method to modify ISO 7199.:2009 "cardiovascular implants and artificial organs blood-gas exchangers (oxygenated Device ".

The main technical differences between this standard and YY 0604-2007 are as follows.

--- increase the chemical performance, validity and other requirements and the corresponding test methods.

The main technical differences between this standard and ISO 7199.:2009 are shown in Table A.1.

Introduction

This standard is designed to effectively exchange gas, auxiliary or replace the lungs of the normal respiratory function of the device, to ensure its safety performance And functional aspects are fully tested, and the characteristics of the cardiopulmonary device to be properly displayed on the device mark.

Therefore, this standard contains the steps to evaluate the cardiopulmonary bypass blood gas exchanger (oxygenator), which describes the measurement of gas conversion, blood Cell failure and the performance of such devices, such as heat exchangers, but not the limits of these characteristics set. The rapid identification of performance characteristics should help the user to select the oxygenator for the patient's needs.

This standard also covers the minimum requirements for the content that must be reported so that the user can add to the performance characteristics of the various standard oxygenators To compare.

This standard refers to other international standards in which a method for determining the common characteristics of various medical devices can be found.

There was no provision for determining the number of microbubbles and the number of unformed components in bovine blood, which is due to the fact that The test method has not yet reached a consensus.

This standard does not include requirements for animal and clinical research, which can be used as part of the manufacturer's quality system. Cardiopulmonary bypass system Blood gas exchanger (oxygenator)

1 Scope

This standard specifies the use of a blood gas exchanger (oxygenator) (hereinafter referred to as oxygenator) for a sterile, disposable cardiopulmonary bypass system It is required that the device be used to oxygenate the blood of the human body and to remove carbon dioxide in the blood (auxiliary or alternative to the extracorporeal circulation of the lung Device).

This standard also applies to heat exchangers as part of the overall oxygenator. This standard does not apply to.

--- implantable oxygenator;

--- liquid oxygenator; Extracorporeal circulation Separate heat exchangers; Separate accessories.

2 Normative reference documents

The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this document. For undated references, the latest edition (including all modifications) applies to this document.

GB/T 14233.1-2008 Methods of test for medical infusion, transfusion, and injectable utensils - Part 1. Chemical analysis methods

GB/T 14233.2-2005 Methods of examination for medical infusion, transfusion, and injectable utensils - Part 2. Biological test methods

GB/T 16886.1 Biological evaluation of medical devices - Part 1. Evaluation and testing in risk management (GB/T 16886.1-2011, ISO 10993-1.:2009, IDT)

GB 18279 Sterilization and routine control of ethylene oxide for medical devices (GB 18279-2000, idtISO 11135..1994)

GB 18280 Sterilization and routine control of health care products Requirements for radiation sterilization (GB 18280-2000, idtISO 11137.

1995) General technical conditions for disposable blood use products GB 19335-2003

GB/T 19633-2005 Packaging of final sterilized medical devices (GB/T 19633-2005, ISO 11607.:2003, IDT)

Medical devices - Symbols for labeling, marking and providing information on medical devices - Part 1. Generic requirements for medical devices YY/T 0466.1-2009 (YY/T 0466.1-2009, ISO 15223.:2007, IDT)

YY/T 0681.1-2009 Test methods for packaging of sterile medical devices - Part 1. Guidelines for accelerated aging testing (YY/T 0681.1-2009, ASTM F1980.:2002, MOD)

3 Terms and definitions

The following terms and definitions apply to this document.

3.1 Blood gas exchanger (oxygenator)

Auxiliary or alternative to the respiratory function of the cardiopulmonary bypass dedicated device.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 18 pages — is available in the English PDF.

Referenced standards

Similar standards

Editions of YY 0604

EditionTitleRevisionStatus
YY 0604-2016Cardiopulmonary bypass systems - Blood-gas exchangers (oxygenators)current editionCurrent
YY 0604-2007Cardiopulmonary bypass systems - Blood-gas exchangers (oxygenators)previous editionSuperseded

This page sells the current edition, YY 0604-2016. Earlier editions are listed for reference only.

How to Download YY 0604-2016

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
18 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YY 0604-2016

$235.00