YY/T 1084-2015Measurement methods of ultrasonic output power for medical diagnostic ultrasonic equipments (English PDF)

医用超声诊断设备声输出功率的测量方法

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for YY/T 1084-2015 in 30 minutes.

Issued by

NMPA

Level / Type

Industry · Recommended

Issue date

March 2, 2015

Implementation date

January 1, 2016

Scope

YY/T 1084-2015 is the English-translated version of 医用超声诊断设备声输出功率的测量方法.

YY/T 1084-2015 is the Chinese pharmaceutical industry standard that gives the methods for measuring the ultrasonic output power of medical diagnostic ultrasound equipment, the radiation force balance method being the preferred one.

Where that method presents a technical difficulty, or where the accuracy of the measurement is assured in another way, the output may instead be derived from hydrophone measurements, and the standard sets out the apparatus, the procedure and the uncertainty of each. Issued on 2 March 2015, it has applied since 1 January 2016.

Found what you need?

Document preview — YY/T 1084-2015

National Standard of the People's Republic of China

ICS
11.040.50
Classification
C 41
Replacing
YY/T 1084-2007

Issued by: National Medical Products Administration of the People's Republic of China

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules. This standard YY/T 1084-2007 The main technical differences are.

--- According to the latest updated version of the reference standard;

--- Frequency range from 0.5MHz ~ 15MHz extended to 0.5MHz ~ 25MHz;

--- In line with GB 9706.9-2008 "Medical electrical equipment - Part 2-37. Ultrasound diagnostic and monitoring equipment to the safety of Seeking "the special requirements of ultrasonic measuring output power, increasing the Appendix A" in the multi mode, scan mode and 1cm × 1cm window Under the mouth, the output power measurement guidance. "

1 Scope

This standard specifies the method for measuring the acoustic output of medical diagnostic ultrasonic equipment power, where the radiation force balance method is the preferred method. Adopting Under radiation force balance method when there is no technical difficulty, or to ensure measurement accuracy of the premise, can also export ultrasound method using hydrophones power.

This standard applies to medical ultrasonic frequency range measured acoustic power output 0.5MHz ~ 25MHz diagnostic equipment.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.

GB/T 7966-2009 Measurement of acoustic radiation force balances power and performance requirements

YY/T 0865.1-2011 ultrasonic hydrophone - Part 1. Measurement and features the following medical ultrasound field 40MH depiction

3 Terms and Definitions

The following terms and definitions apply to this document.

3.1 Ultrasonic transducer

In the ultrasonic frequency range, the electrical energy into mechanical energy and (or) convert mechanical energy into electrical energy.

3.2 Output power

Acoustic output power ultrasonicoutputpower Under certain medium (preferably water) specify the conditions to free field emitted by the ultrasound transducer time-averaged acoustic power.

Note 1. "time-average" is averaged over an integer number of cycle.

Note 2. in watts (W).

3.3 Limited power output side area

Max transducer radiating any 1cm² square area, the average time of the emitted acoustic power output. 1cm² square area Field in the X and Y dimensions are 1cm. P1 × 1

Note: in watts (W).

3.4 Radiation

Acoustic radiation force acousticradiationforce Acting on the sound field of an object does not include the sound of a rush current action time-averaged force caused by the sound field; a more general definition is to exclude sound

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

Editions of YY/T 1084

EditionTitleRevisionStatus
YY/T 1084-2015Measurement methods of ultrasonic output power for medical diagnostic ultrasonic equipmentscurrent editionCurrent
YY/T 1084-2007Measurement methods of ultrasonic output power for medical diagnostic ultrasonic equipmentsprevious editionSuperseded

This page sells the current edition, YY/T 1084-2015. Earlier editions are listed for reference only.

How to Download YY/T 1084-2015

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YY/T 1084-2015

$185.00