YY/T 0850-2011Guide for evaluation of uncertainty in measurement of ultrasonic diagnostic and monitoring equipment acoustic output characteristics (English PDF)
超声诊断和监护设备声输出参数测量不确定度评定指南
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for YY/T 0850-2011 in 30 minutes.
Issued by
NMPA
Level / Type
Industry · Recommended
Issue date
December 31, 2011
Implementation date
June 1, 2013
Scope
YY/T 0850-2011 is the English-translated version of 超声诊断和监护设备声输出参数测量不确定度评定指南.
YY/T 0850-2011 is the Chinese pharmaceutical industry standard that guides the evaluation of the uncertainty in the measurement of the acoustic output characteristics of ultrasonic diagnostic and monitoring equipment.
It gives the terms and definitions, lists the main sources of uncertainty, sets out the procedure by which the uncertainty is assessed and evaluated and fixes the way it is reported and expressed. Issued on 31 December 2011, it has applied since 1 June 2013.
Found what you need?
Document preview — YY/T 0850-2011
National Standard of the People's Republic of China
- ICS
- 11.40.55; 17.140.50
- Classification
- C 41
Issued by: National Medical Products Administration of the People's Republic of China
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Terms
- 4 Measurement Uncertainty assessment procedures
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
1 Scope
This standard specifies the ultrasound diagnostic and monitoring equipment acoustic output parameter measurement uncertainty of terms and definitions, the main sources of uncertainty, Uncertainty assessment procedures and uncertainty evaluation, reporting and representation.
This standard applies to the ultrasound diagnostic and monitoring equipment (hereinafter referred to as "equipment") sound output parameter measurement Uncertainty Evaluation.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.
Analyzing and processing GB/statistical processing and interpretation of normal sample outliers T 4883-2008 data
GB 9706.9-2008 Medical electrical equipment - Part 2-37. Ultrasound diagnostic and monitoring equipment requirements for the safety JJF 1001-2011 common measurement terms and definitions JJF 1059-1999 Evaluation and Expression of Uncertainty in Measurement
3 Terms
GB 9706.9-2008, JJF 1001-2011 and JJF 1059-1999 defined and the following terms and definitions apply to this document.
3.1 Ultrasound diagnostic and monitoring equipment
For medical diagnosis, monitoring the use of ultrasound on human inspection medical electrical equipment.
Note: adapted from GB 9706.9-2008, the definition 2.1.145.
3.2 Acoustic output parameters
Describe the sound field characteristic of a number of parameters. The standard refers specifically to the sound field of ultrasonic sound field.
4 Measurement Uncertainty assessment procedures
Measured 4.1 Description When measured general description shall include the following.
a) The test procedure is described;
b) affect the measured parameters to be measured and clear units, measuring/test basis;
c) the relationship between the parameters to be measured and its influence (input), the mathematical model, given the measured parameters y and xi influence the relationship. y = f (X1, X2, X3)
Depending on the nature of the mathematical model to determine the combined standard uncertainty of the applicable formula can be omitted if the calculation and dissemination be measured coefficient. School d) the known systemic effects of positive value;
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
GB 9706.9-2008
Similar standards
How to Download YY/T 0850-2011
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
YY/T 0297-2026 — General requirements for clinical investigation of medical devices
YY/T 0479-2026 — Medical diagnostic X-ray tube assemblies and X-ray source assemblies - Determination of maximum symmetric radiation field
YY/T 0492-2026 — Implantable leads
Secure payment via Stripe
Payments accepted
YY/T 0850-2011
$145.00