YY/T 1278-2015Measuring methods for beam area of medical ultrasound equipment transducer (English PDF)

医用超声设备换能器声束面积测量方法

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for YY/T 1278-2015 in 30 minutes.

Issued by

NMPA

Level / Type

Industry · Recommended

Issue date

March 2, 2015

Implementation date

January 1, 2016

Scope

YY/T 1278-2015 is the English-translated version of 医用超声设备换能器声束面积测量方法.

YY/T 1278-2015 is the Chinese pharmaceutical industry standard that gives the terms, the definitions, the test device and the method for measuring the beam area of the transducer of medical ultrasound equipment.

It applies to diagnostic and to therapeutic ultrasound equipment alike, and it sets out the hydrophone and the scanning arrangement, the way the beam cross-section is determined from the measured field and the way the result is reported. Issued on 2 March 2015, it has applied since 1 January 2016.

Found what you need?

Document preview — YY/T 1278-2015

National Standard of the People's Republic of China

ICS
11.040.50
Classification
C 41

Issued by: National Medical Products Administration of the People's Republic of China

Contents

  • Foreword
  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions YY/T 0865.1-2011 defined in the following
  • 4 Measuring various types of test equipment requirements

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules.

Introduction

In the sound field parameter measurements for medical ultrasound equipment, the transducer acoustic beam area is a very important indicator, but also to calculate other acoustic output A basic data parameters. Beam area where different standards, depending on the use and technical requirements definition, measurement methods, Measurement accuracy, the position of the beam axis, but also different, but the content and basic measurement method is similar to the definition of these methods Scattered in various and specific requirements related to standards. This standard organizes relevant standards and technical literature, defined the various types of equipment Measuring beam area requirements and methods of measurement. Medical Ultrasound equipment transducer beam area measurement methods

1 Scope

This standard specifies the terms of medical ultrasound equipment transducer beam area measurement, definitions, test device and method.

This standard applies to medical ultrasound diagnostic equipment and therapeutic medical ultrasound equipment.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.

GB 9706.9-2008 Medical electrical equipment - Part 2-37. Ultrasound diagnostic and monitoring equipment requirements for the safety

GB/T 16846-2008 acoustic output of medical diagnostic ultrasonic equipment disclosure requirements JJF 1059-1999 Evaluation and Expression of Uncertainty in Measurement

YY 0592-2005 high intensity focused ultrasound (HIFU) therapy system

YY/T 0750-2009 ultrasound physiotherapy equipment within the frequency range of 0.5MHz ~ 5MHz sound field requirements and methods of measurement

YY/T 0850-2011 ultrasound diagnostic and monitoring equipment Acoustic Output parameter Measurement Uncertainty Guide

YY/T 0865.1-2011 ultrasonic hydrophone - Part 1. Measurement and features 40MHz describe the following medical ultrasound field

3 Terms and Definitions

YY/T 0865.1-2011 defined in the following terms and definitions apply to this document.

3.1 And other sound-pressure line acousticpressureisohypse

Compared with the peak measurement, set the attenuation in decibels is equal to the measuring point (see Figure 2).

3.2 Beam area

Specified plane perpendicular to the beam axis, the area of the square pulse sound pressure measurement points and other specified sound pressure line surrounded.

3.3 Beam cross-sectional area

On the beam is perpendicular to the axis of the collimator specific plane, the mean square of the sound pressure and the total mean-square sound pressure minimum area of 75%.

3.4 Sound pressure focus area

pressurefocalarea In the focal plane of the sound pressure, sound pressure around the focal point of a sound pressure line and other enclosed area.

4 Measuring various types of test equipment requirements

4.1 Diagnostic Equipment

For a particular kind of work mode, diagnostic equipment general requirements for the measurement beam area on two horizontal plane, one of which is the end face of the transducer Nearby, another usually collimated beam axis space-time peak at the maximum peak sound pressure level (zmax) horizontal plane.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download YY/T 1278-2015

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YY/T 1278-2015

$205.00