YY/T 0750-2026Ultrasound - Physiotherapy equipment - Sound field requirements and measurement methods in the frequency range of 0.5MHz to 5MHz (English PDF)
This is a limited preview
Buy now to download the full PDF (33 pages)
Need quotation for your management?
Get a formal quotation for YY/T 0750-2026 in 30 minutes.
Issued by
National Medical Products Administration
Level / Type
National · Recommended
Issue date
March 9, 2026
Implementation date
March 1, 2027
Scope
YY/T 0750-2026 (Ultrasound - Physiotherapy equipment - Sound field requirements and measurement methods in the frequency range of 0.5MHz to 5MHz) is available as an English-translated PDF.
YY/T 0750-2026 — This document stipulates that. ---Methods for measuring and characterizing the output of ultrasound therapy equipment based on benchmark testing methods; ---Characteristics specified by the ultrasound therapy equipment manufacturer based on benchmark test methods; ---Safety guidelines for ultrasonic sound fields generated by ultrasonic therapy equipment; ---Measuring and characterization methods for the output of ultrasound therapy equipment based on conventional experimental methods; ---Acceptance criteria for the output of ultrasound physiotherapy equipment based on conventional testing methods.
This document applies to continuous or quasi-continuous waves (such as burst waves) generated by ultrasonic transducers within the frequency range of 0.5MHz to 5MHz.
This is an ultrasound device designed for therapeutic purposes. The device uses a single-planar, non-focused circular transducer as the treatment head. The generated static sound beam is perpendicular to the end face of the treatment head.
Note 1.This document does not include the treatment parameters and usage methods of the ultrasound therapy equipment. Note 2.Ultrasonic therapy equipment with a frequency range of 20kHz to 500kHz is specified by IEC 63009.
Found what you need?
Document preview — YY/T 0750-2026
National Standard of the People's Republic of China
- ICS
- 11.040.60
- Classification
- C 41
- Replacing
- YY/T 0750-2018
Issued by: National Medical Products Administration
Contents
- Foreword
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
Foreword
This document complies with the provisions of GB/T 1.1-2020 "Standardization Work Guidelines Part 1: Structure and Drafting Rules of Standardization Documents".
Drafting.
This document replaces YY/T 0750-2018 "Sound Field Requirements and Measurement for Ultrasonic Therapy Equipment in the Frequency Range of 0.5MHz~5MHz".
Compared with YY/T 0750-2018, the main technical changes in the "Methods" are as follows, except for structural adjustments and editorial modifications.
---The requirements for dissolved oxygen content in degassed water during testing have been changed (see 6.1, 2018 version 6.1);
---The requirements for the test container have been changed (see 6.2, 2018 version 6.2);
---The nature of Appendix A has been changed (see Appendix A, Appendix A of the 2018 edition);
---The description in Appendix D has been changed (see Appendix D, Appendix D of the 2018 edition).
This document modifies and adopts IEC 61689:2022 "Ultrasound therapy equipment - sound field requirements and measurement in the frequency range of 0.5MHz to 5MHz".
Quantification method.
The technical differences between this document and IEC 61689:2022, and the reasons therefor, are as follows.
---IEC 60601-1 has been replaced with the normatively referenced GB 9706.1.The degree of consistency between the two documents is modified to adapt...
my country's national conditions;
---IEC 60601-2-5 has been replaced with the normatively referenced GB 9706.205.The consistency between the two documents is [modification level].
Adapting to my country's national conditions;
---IEC 61161 has been replaced with the normatively referenced GB/T 7966, and the two documents are considered equivalent to meet my requirements.
The country's national conditions;
---IEC 62127-1 has been replaced with the normatively referenced YY/T 0865.1.The consistency between the two documents is considered a modification to adapt.
In accordance with my country's national conditions;
---The descriptions of "solid Y line" and "dashed Y line" under Figure A.1 have been revised to be consistent with the descriptions in Figure A.1 and A.4.2.
Please note that some content in this document may involve patents. The issuing organization of this document assumes no responsibility for identifying patents.
This document was proposed by the National Medical Products Administration.
This document is under the jurisdiction of the Medical Ultrasonic Equipment Subcommittee of the National Technical Committee on Standardization of Medical Electrical Appliances (SAC/TC10/SC2).
Introduction
The ultrasound therapy device consists of a high-frequency electric power generator and a handheld treatment head. The treatment head contains a disc typically made of piezoelectric material.
It is made into a transducer used to convert electrical energy into ultrasound waves. The treatment head is often designed to come into contact with the human body.
Ultrasonic therapy equipment 0.5MHz~5MHz Sound field requirements and measurement methods within the frequency range
1 Scope
This document stipulates that.
---Methods for measuring and characterizing the output of ultrasound therapy equipment based on benchmark testing methods;
---Characteristics specified by the ultrasound therapy equipment manufacturer based on benchmark test methods;
---Safety guidelines for ultrasonic sound fields generated by ultrasonic therapy equipment;
---Measuring and characterization methods for the output of ultrasound therapy equipment based on conventional experimental methods;
---Acceptance criteria for the output of ultrasound physiotherapy equipment based on conventional testing methods.
This document applies to continuous or quasi-continuous waves (such as burst waves) generated by ultrasonic transducers within the frequency range of 0.5MHz to 5MHz.
This is an ultrasound device designed for therapeutic purposes. The device uses a single-planar, non-focused circular transducer as the treatment head.
The generated static sound beam is perpendicular to the end face of the treatment head.
Note 1.This document does not include the treatment parameters and usage methods of the ultrasound therapy equipment.
Note 2.Ultrasonic therapy equipment with a frequency range of 20kHz to 500kHz is specified by IEC 63009.
2 Normative references
The contents of the following documents, through normative references within the text, constitute essential provisions of this document. Dated citations are not included.
For references to documents, only the version corresponding to that date applies to this document; for undated references, the latest version (including all amendments) applies.
This document.
GB/T 7966 Acoustic ultrasonic power measurement – Radiation force balance method and its requirements (GB/T 7966-2022, IEC 61161.
2013, IDT)
GB 9706.1 Medical electrical equipment – Part 1: General requirements for basic safety and basic performance (GB 9706.1-2020) IEC 60601-1:2012, MOD) GB 9706.205 Medical electrical equipment – Part 2-5.Particular requirements for basic safety and basic performance of ultrasound therapy equipment (GB 9706.205-2020,IEC 60601-2-5:2009,MOD) YY/T 0865.1 Ultrasonic hydrophones – Part 1: Measurement and characterization of medical ultrasonic fields (YY/T 0865.1-2024, IEC 62127-1:2022, MOD)
3 Terms and Definitions
The following terms and definitions apply to this document.
Rated output power, total uncertainty of rated output power at 95% confidence level, and rated grid voltage fluctuation under ±10% conditions.
The sum of the three factors that determine the maximum increment of the fixed output power.
Note 1.The possibility of rated output power fluctuation under a rated grid voltage fluctuation of ±10% should be addressed by adjusting the voltage between the grid power supply and the ultrasound therapy equipment.
Verify by adjusting the output transformer; detailed guidelines can be found in Appendix A, section A.2.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 33 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 7966Acoustics - Ultrasonic power measurement - Radiation force balances and the requirements
- GB/T 7966-2022Acoustics - Ultrasonic power measurement - Radiation force balances and the requirements
- GB 9706.1Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
- GB 9706.1-2020Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
- GB 9706.205Medical electrical equipment - Part 2-5: Particular requirements for the basic safety and essential performance of ultrasonic physiotherapy equipment
- GB 9706.205-2020Medical electrical equipment - Part 2-5: Particular requirements for the basic safety and essential performance of ultrasonic physiotherapy equipment
IEC 61161 · IEC 60601 · IEC 62127
Cited by
- YY/T 0865.1-2024Ultrasonics - Hydrophones - Part 1: Measurement and characterization of medical ultrasonic fields
- GB/T 36419-2018Household and similar beauty care appliances
- YY/T 1090-2018Ultrasonic physiotherapy equipment
- YY/T 1278-2015Measuring methods for beam area of medical ultrasound equipment transducer
- YY/T 0865-2011Ultrasonics - Hydrophones - Part 1: Measurement and characterization of medical ultrasonic fields
How to Download YY/T 0750-2026
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 9706.1-2020 — Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
GB 9706.103-2020 — Medical electrical equipment - Part 1-3: General requirements for basic safety and essential performance. Collateral Standard: Radiation protection in diagnostic X-ray equipment
GB 9706.12-1997 — Medical electrical equipment Part 1: General requirements for safety 3. Collateral standard: General requirements for radiation protection in diagnostic X-ray equipment
Secure payment via Stripe
Payments accepted
YY/T 0750-2026
$845.00