GB/T 11807-2021Characteristics, design and operational procedures for acoustic monitoring systems of loose parts detection important to safety in nuclear power plants (English PDF)
Also coversGBT11807-2021
Open the GB/T 11807-2021 preview as PDF
This is a limited preview
Buy now to download the full PDF
Issued by
State Administration for Market Regulation, China National Standardization Administration
Level / Type
National · Recommended
Issue date
December 31, 2021
Implementation date
July 1, 2022
Scope
GB/T 11807-2021 (Characteristics, design and operational procedures for acoustic monitoring systems of loose parts detection important to safety in nuclear power plants) is available as an English-translated PDF.
GB/T 11807-2021 — This document specifies the characteristics, design requirements and operating procedures of acoustic monitoring systems for loose components of nuclear power plant reactor coolant systems: This document applies to the design and operation of a monitoring system for loose parts of a reactor coolant system:
Document preview — GB/T 11807-2021
National Standard of the People's Republic of China
- Classification
- F 65
Issued by: State Administration for Market Regulation, China National Standardization Administration
Contents
- foreword
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
foreword
This document is in accordance with the provisions of GB/T 1:1-2020 "Guidelines for Standardization Work Part 1: Structure and Drafting Rules of Standardization Documents"
drafted:
This document replaces GB/T 11807-2008 "Characteristics, Design and Operational Procedures for Acoustic Monitoring Systems for Detecting Loose Parts", and
Compared with GB/T 11807-2008, in addition to structural adjustment and editorial changes, the main technical changes are as follows:
--- Modified the scope of the standard (see Chapter 1, Chapter 2 of the:2008 edition);
--- Added normative references (see Chapter 2);
--- Added the terms "alarm monitor", "monitoring signal", "known event" and their definitions (see 3:11, 3:12, 3:13);
--- Delete the terms "monitoring area", "foreign object", "frequency distribution of burst wave interval", "frequency distribution of burst wave amplitude", "system spirit"
"Sensitivity" "passband" and its definition (see 2:1, 2:2:3, 2:7, 2:8, 2:10, 2:11 of the:2008 edition);
--- Modified the terms and definitions "loose parts", "structure sound" and "noise floor" (see 3:1, 3:4, 3:6, 2:2, 2:3,:2008 edition)
2:5);
--- Modified the general description about loose parts monitoring (see Chapter 4, Chapter 3 of the:2008 edition);
--- Revised "Characteristics and design requirements of each functional unit of the monitoring system" (see Chapter 5, Chapter 4 of the:2008 edition);
--- Revised the relevant requirements of the initial start-up test (see Chapter 6, Chapter 5 of the:2008 edition);
--- Revised the relevant requirements of the supervision program (see Chapter 7, Chapter 6 of the:2008 edition);
--- Added the description of the loose parts monitoring system in the document requirements [see Chapter 8 a)];
This document is modified to adopt IEC 60988:2009 "Acoustic monitoring systems for detecting loose parts of instruments important to safety in nuclear power plants: Characteristics,
Design Criteria and Operating Procedures:
This document has been structurally adjusted compared to IEC 60988:2009:
---3:1~3:13 correspond to 3:9, 3:7, 3:10, 3:18, 3:16, 3:3, 3:17, 3:14, 3:15, 3:6, 3:2,
3:11, 3:8;
---Divided some clauses of IEC 60988:2009:
The technical differences between this document and IEC 60988:2009 and their reasons are as follows:
--- In order to meet the requirements of the preparation of Chinese standards, the scope of the standard has been revised:
--- Regarding normative reference documents, this document has made adjustments with technical differences to adapt to the technical conditions of our country and the circumstances of the adjustment:
The situation is reflected in Chapter 2 "Normative References", and the specific adjustments are as follows:
* Replacing IEC 61226 with GB/T 15474 modified to adopt international standards (see 5:1:2);
* Replace IEC 61513 (see 5:1:2) with NB/T:20026 modified to adopt international standards:
--- In order to meet the compilation requirements of Chinese standards, the terms "burst wave interval distribution" and "burst wave amplitude" in IEC 60988:2009 are deleted:
Distribution", "Single Channel Alarm Suppression", "Adaptive Resonance Frequency", "Resonance Factor" and their definitions:
--- Put some annotations of IEC 60988:2009 in the text:
The following editorial changes have been made to this document:
--- In order to harmonize with existing standards, the name of the standard is changed to "Characteristics, design and
Operating Procedures":
Please note that some content of this document may be patented: The issuing agency of this document assumes no responsibility for identifying patents:
1 Scope
This document specifies the characteristics, design requirements and operating procedures of acoustic monitoring systems for loose components of nuclear power plant reactor coolant systems:
This document applies to the design and operation of a monitoring system for loose parts of a reactor coolant system:
2 Normative references
The contents of the following documents constitute essential provisions of this document through normative references in the text: Among them, dated citations
documents, only the version corresponding to that date applies to this document; for undated references, the latest edition (including all amendments) applies to
this document:
GB/T 15474 Classification of instrumentation and control functions important to safety in nuclear power plants (GB/T 15474-2010, IEC 61226:2005,
MOD)
NB/T:20026 General requirements for instrumentation and control systems important to safety in nuclear power plants (NB/T:20026-2014, IEC 61513:2011,
MOD)
3 Terms and Definitions
The following terms and definitions apply to this document:
3:1
loosepart
A collective term for fallen parts, loose parts and residues during construction, refuelling and maintenance of nuclear power plants:
3:2
detachedpart
A component that has lost connection to a component within the pressure boundary of the reactor coolant and thus can be carried by the reactor coolant:
3:3
loose parts loosenedpart
A part that has been loosened but remains connected to the original fixed part:
3:4
structure-bornesound
Sounds with frequencies in the audible range propagating on the surface of metal structures:
3:5
sound sensor
A transducer that converts a mechanical signal to an electrical signal and receives sound at the outer surface of the reactor coolant pressure boundary, which is assisted by a bit
motion, velocity or acceleration detection:
Note: Sound sensors in this document refer to sensors that detect "structure sound":
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.
Referenced standards
Normative references
GB/T 15474 · GB/T 15474-2010 · IEC 61226 · IEC 61513
How to Buy GB/T 11807-2021
- 1Add to cart. Click the "Buy GB/T 11807-2021" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 46830.2-2026 — Plastics - Liquid crystal polymer (LCP) moulding and extrusion materials - Part 2: Preparation of test specimens and determination of properties
GB/T 28593-2026 — Sand and dust weather warning levels
GB/T 19608.3-2026 — Classification of special environmental conditions - Part 3: Plateau
Secure payment via Stripe
Payments accepted
GB/T 11807-2021
$425.00