QC/T 1170-2022Functional films for automotive glass (English PDF)
汽车玻璃用功能膜
This is a limited preview
Buy now to download the full PDF (38 pages)
Need quotation for your management?
Get a formal quotation for QC/T 1170-2022 in 30 minutes.
Issued by
MIIT
Level / Type
Industry · Recommended
Issue date
April 8, 2022
Implementation date
October 1, 2022
Scope
QC/T 1170-2022 is the English-translated version of 汽车玻璃用功能膜.
QC/T 1170-2022 covers performance film for automotive glass, giving the terms and definitions, classification and marking, requirements, test methods, inspection rules and the packaging and storage provisions.
It applies to film mounted on the inner surface of motor vehicle window glass and on interior partition glass; film on other vehicles may use it as a reference.
Total solar infrared thermal rejection is calculated from spectral transmittance, reflectance and film emissivity measured from 780 nm to 2500 nm. Secondary image deviation and optical distortion are tested on film applied to a windshield, to GB/T 5137.2-2020.
Haze is measured on three 100 mm x 100 mm films mounted on 3 mm flat glass of 89% plus or minus 1% visible light transmittance, before and after 100 rotations of abrasion.
Maximum tensile force at break and elongation at break use three specimens of 200 mm by 25 mm plus or minus 0.5 mm.
Aging resistance runs 600 h of irradiation with a blackboard temperature of 63 degrees C plus or minus 3 degrees C and an irradiance of 1000 W/m2 plus or minus 75 W/m2 over 300 nm to 800 nm, 110 W/m2 plus or minus 5 W/m2 over 300 nm to 400 nm, or 0.93 W/m2 plus or minus 0.02 W/m2 narrow band at 340 nm.
Normative appendices set the specimen mounting method and the bag-method determination of formaldehyde emission by phenol reagent spectrophotometry at 630 nm and of benzene series release by thermal desorption gas chromatography-mass spectrometry.
Found what you need?
Document preview — QC/T 1170-2022
National Standard of the People's Republic of China
Issued by: Ministry of Industry and Information Technology of the People's Republic of China
Contents
- Foreword6
- 1 Scope7
- 2 Normative references7
- 3 Terms and definitions8
- 4 Classification and markings10
- 5 Requirements10
- 6 Test method15
- 7 Inspection rules26
- 8 Marking, packaging, transportation, storage29
- Appendix A (Informative) Selection of performance films for automotive glass30
- Appendix B (Normative) Mounting method of performance film sample31
- Appendix C (Normative) Determination of formaldehyde emission in performance spectrophotometry33
- Appendix D (Normative) Determination of release of benzene series in performance desorption/gas chromatography-mass spectrometry38
1 Scope
This document specifies the terms and definitions, classification and marking, requirements, test methods, inspection rules, packaging, marking, transportation, storage, etc. of performance films for automotive glass.
This document is applicable to the performance film, which is mounted on the inner surface of the motor vehicle window glass and the surface of the interior partition glass.
The performance film mounted on the glass surface of other vehicles can use this standard as a reference.
2 Normative references
The contents of the following documents constitute the essential provisions of this document through normative references in the text. Among them, for dated references, only the version corresponding to the date is applicable to this document; for undated references, the latest version (including all amendments) is applicable to this document.
GB/T 191 Packaging - Pictorial marking for handling of goods
GB/T 1040.1-2018 Plastics - Determination of tensile properties - Part 1: General principles (ISO 527-1:2012, IDT)
GB/T 2680-2021 Glass in building - Determination of light transmittance, solar direct transmittance, total solar energy transmittance, ultraviolet transmittance and related glazing factors
GB/T 3979 Methods for the measurement of object color
GB/T 5137.1-2020 Test methods of safety glazing materials used on road vehicles - Part 1: Mechanical properties tests (ISO 3537:2015, MOD)
GB/T 5137.2-2020 Test methods of safety glazing materials used on road vehicles - Part 2: Optical properties tests (ISO 3538:1997, MOD)
GB/T 11942 Test method of chroma for colour building materials
GB/T 16422.2-2014 Plastics - Methods of exposure to laboratory light sources - Part 2: Xenon-arc sources (ISO 4892-2:2006, IDT)
GB/T 29061 Performance films for glass in building
6.9 Secondary image deviation
Attach 3 pieces of performance film to the inner surface of the windshield glass of the automobile, that meets the requirement for the deviation of the secondary image specified in GB 9656. The mounting method shall be in accordance with the provisions of GB/T 31848. Place it under the environment as specified in 6.1 for 7 days. It shall be tested, according to the method specified in Chapter 6 of GB/T 5137.2-2020.
6.10 Optical distortion
Attach 3 pieces of performance film to the inner surface of the windshield glass, that meets the optical distortion requirements stipulated in GB 9656. The mounting method shall be in accordance with the provisions of GB/T 31848. Place it under the environment as specified in 6.1 for 7 days. It shall be tested, according to the method specified in Chapter 7 of GB/T 5137.2-2020.
6.11 Color consistency
6.11.1 Specimen
Cut a specimen, which has a length of 1000 mm and a width equal to the package width, at any position within a packaging unit. Take 5 samples of 50 mm x 50 mm, from the four corners and the middle of the specimen. The outer edge of the specimen is 50 mm from the edge of the film, as shown in the figure 4.
According to the spectrophotometric colorimetric method specified in GB/T 3979, measure the spectral transmittance of the specimen, under the red, yellow, green light sources that meet the chromaticity requirements specified in GB 14887. Use the CIE 1931 standard chromaticity system, to calculate the chromaticity coordinates.
Visually observe the colors of warning signs, prohibition signs, instruction signs, that comply with the provisions of GB 5768.2-2009, through the specimen.
6.13 Haze
6.13.1 Specimen
Mount three pieces of 100 mm x 100 mm performance film, on the same size of 3 mm flat glass, which has a visible light transmittance of 89% ± 1%, to make a specimen.
See Appendix B for the mounting method. Place the specimen under the conditions specified in 6.1 for at least 24 h before the test.
6.13.2 Test device
The haze meter and abrasion meter shall comply with the provisions of GB/T 5137.1-2020.
6.13.3 Measurement
The initial haze shall be measured according to the method specified in 7.5.3 of GB/T 5137.1-2020. Then the specimen shall be cleaned and ground 100 rotations, according to the method specified in Chapter 7 of GB/T 5137.1-2020. Measure the haze after abrasion. Calculate the difference between the haze after abrasion and the initial haze.
6.14.1 Specimen
Take 3 performance films of 200 mmx (25 mm ± 0.5 mm), as shown in Figure 5. It shall ensure that the edges of the specimen are neat and smooth without gaps. It shall be placed, at least 24 hours, under the conditions specified in 6.1, before the test.
6.17 Aging resistance
6.17.1 Specimen
According to the method in 6.15.1, respectively attach three 250 mm x (25 ± 0.5) mm performance films, to a 3 mm flat glass which is 125 mm x 50 mm AND has a visible light transmittance of 89% ± 1%, to make specimen. It shall be placed under the conditions specified in 6.1, for at least 7 days before the test.
6.17.2 Test device
The aging test chamber includes an irradiation system, a temperature control system, and a blackboard temperature measuring device. The light source of the irradiation system shall meet the requirements of GB/T 16422.2-2014, being equipped with the arc lamp with daylight filter or equivalent light source. The irradiance of the specimen surface is 1000 W/m2 ± 75 W/m2 in a wider passband (300 nm ~ 800 nm), or 110 W/m2 ± 5 W/m2 in a wide passband (300 nm ~ 400 nm), or 0.93 W/m2 ± 0.02 W/m2 in a narrow passband 340 nm. The temperature of the blackboard inside the chamber is 63 °C ± 3 °C.
6.17.3 Measurement
Measure the visible light transmittance and ultraviolet transmittance of the specimen, according to 6.4 and 6.6, respectively. Measure the solar infrared direct transmittance of the specimen, according to the method specified in 5.13 of GB/T 2680-2021. Then put the specimen glass face up into the aging chamber. Take it out after continuous irradiation for 600 h. After standing for 24 hours under the conditions specified in 6.1, make observation. Then measure the visible light transmittance and ultraviolet transmittance of the specimen, according to 6.4 and 6.6. Measure the solar infrared direct transmittance of the specimen, according to the method specified in 5.13 of GB/T 2680-2021. Respectively calculate the visible light transmittance, ultraviolet transmittance, solar infrared direct transmittance difference. Measure the bonding force, according to 6.15.3.
6.18 Combustion resistance
6.18.1 Specimen
Attach three pieces of 300 mm x 76 mm performance film on a 3 mm flat glass, which is the same size, to make a specimen. See Appendix B for the attachment method. Place at least 7 days, under the conditions specified in 6.1, before the test.
6.18.2 Test device
The test device shall comply with the provisions of GB 8410.
7.3.2 Exit-factory inspection
7.3.2.2 Other inspection items to be determined through negotiation by supplier and purchaser If all specimens required by each inspection item meet the requirements, the item is considered qualified.
7.3.2.1 Appearance quality, size deviation, visible light transmittance
If the above-mentioned items meet the requirements of acceptance number in the exit-factory inspection sampling plan, which is formulated by the enterprise, the item is considered qualified.
7.3.2.3 Comprehensive judgment
If all the items required in 7.3.2.1 and 7.3.2.2 are qualified, the exit-factory inspection of this batch of products is considered to be qualified. If there is one unqualified item, this batch of products fail the exit-factory inspection.
8 Marking, packaging, transportation, storage
8.1 Marking
Packaging marks shall comply with the provisions of GB/T 191. It shall include product name, mark, factory name, factory address, trademark, specification, quantity, batch number, production date, implemented standards. It shall be marked with words such as "handle with care, avoid rain, avoid moisture".
8.2 Packaging
The product is packaged in sealed moisture-proof packaging. The packaging materials shall comply with relevant national standards.
8.3 Transportation
Product transportation shall comply with relevant national regulations. Rainproof and sunscreen measures shall be taken during transportation.
8.4 Storage
The product is stored in a well-ventilated, rain-proof, moisture-proof, fire-proof place.
B.1 Mounting conditions
Except for specific requirements, mounting shall be carried out in a clean, dust-free, airtight room, at a temperature of 15 °C ± 25 °C and a relative humidity of 50% ~ 75%.
B.2 Mounting tools
Cleaning installation fluid, watering can, cleaning scraper, wiper, water squeezing shovel, Teflon water squeezing sheet, film cutting knife, film cutting guide and ruler, lint-free absorbent paper towels, etc.
B.3 Mounting
B.3.1 Glass cleaning
Clean the glass. Remove the stains on the glass surface. Use a cleaning scraper to scrape off the dirt, if necessary. Use a lint-free absorbent paper towel, to wipe the glass, to ensure it is clean.
B.3.2 Mounting
B.3.2.1 Lamination
Remove the protective film from the cut performance film. Spray cleaning installation liquid evenly on the installation rubber surface and glass surface. Cover the film. Spray the cleaning installation liquid on the surface of the performance film. Use a wiper, to scrape back and forth on the performance film, in the horizontal direction for 2 ~ 3 times, to make the performance film stick to the correct position.
B.3.2.2 Water squeezing
Spray the cleaning installation liquid on the surface of the performance film again. First, move a squeeze shovel, starting from the top of the performance film, in the up, down, left, right direction. Squeeze the whole piece of glass, at the same pressure, angle, overlapping movements, to remove the cleaning installation fluid remaining between gap between the performance film and the glass. Before the final extrusion, use a film cutter to cut off the possible excess of the edge of the performance film. Then use a lint-free paper towel, to wrap the Teflon water squeeze sheet, to squeeze out the residual water using a steady force. At the same time, keep changing the position of the paper
Appendix C (Normative) Determination of formaldehyde emission in performance films for automotive glass by bag method - Solution absorption - phenol reagent spectrophotometry
C.1 Measuring range
This method is suitable for the determination of formaldehyde emission in performance films for automotive glass.
The detection limit of this method is 0.027 µg; the lower limit of determination is 0.108 µg. When the specimen area is 0.18 m2, the inflated volume of the sampling bag is 5.0 L, the sampling volume of the absorption liquid is 1.0 L, THEN, the minimum detection concentration of the method is 0.001 mg/m², the minimum quantitative concentration is 0.003 mg/m².
C.2 Method principle
Use the bag method, to put the performance film for automotive glass into the sampling bag. Heat it at 60 °C, to make free formaldehyde dissipate in the sampling bag. Use a large bubble absorption tube filled with phenol reagent, to collect gas samples.
Formaldehyde reacts with phenol reagent, to produce azine. In acidic solution, azine is oxidized by iron ions to a blue compound, which is quantified by measuring the absorbance, at a wavelength of 630 nm by a spectrophotometer.
C.3 Reagents and materials
Unless otherwise stated, analytically pure chemical reagents in compliance with national standards are used for analysis; the distilled water is used for experiments.
C.3.1 Phenol reagent (3-methyl-2-benzothiazole hydrazone hydrochloride) solution, 1 g/L: Put it in a brown bottle. Store it in the refrigerator. This liquid is colorless and transparent. It gradually becomes red after standing and becomes darker. It can be stored for about 3 months (it is light red). If it is stored for a long time, small brownish red precipitates will appear, which can still be used after filtration; however, the background value of absorbance will increase.
C.3.2 Absorption solution: Use water to dilute 5 mL of phenol reagent solution (C.3.1), to make it to 100 mL. Prepare it before use.
C.3.3 Ferric sulfate solution, 10 g/L: Weigh 1 g of ferric ammonium sulfate [NH4Fe(SO4)2·12H2O, superior grade]. Dissolve it in 0.1 mol/L hydrochloric acid solution. Dilute to 100 mL. Store it in a brown bottle. It can be stored for 6 months in.
For GC-MS performance test. Take an appropriate amount of chromatographically pure 4-bromofluorobenzene (BFB), to prepare it in a certain volume of methanol (D.3.1).
D.3.4 Standard stock solution: rho = 1000 µg/mL
Purchase a chromatographically pure target compound. Take a certain volume. Use methanol (D.3.1), to dilute it, to configure it as a standard stock solution of 1000 µg/mL. Commercially available certified mixed standard solutions are also available.
D.3.5 Nitrogen: Purity >= 99.999%
Oxygen and organic filters shall be installed in the carrier gas path. These filters shall be replaced periodically, according to the manufacturer's instructions.
D.3.6 High-purity nitrogen: Purity >= 99.999%
D.3.7 Sampling bag: Made of polyvinyl fluoride (PVF), which has a capacity of 10 L, equipped with a gas inlet/outlet valve, sealed with PE strips.
D.3.8 Adsorption tube: Made of stainless steel, which has an inner diameter of 5 mm.
Combination 1 adsorption tube: Tenax GR and Carbopack B are installed inside, the lengths of which are 30 mm and 25 mm, respectively.
Combination 2 adsorption tubes: Carbopack B and Carboxen 1000 are installed inside, the lengths of which are 30 mm and 10 mm, respectively.
Combination 3 adsorption tubes: Carbopack C, Carbopack B, Carboxen 1000 are installed inside, the lengths of which are 13 mm, 25 mm, 13 mm, respectively. OR use another product with the same functionality.
D.3.9 Adsorbent: Tenax GR (specific surface area 35 m²/g), Carbopack B (specific surface area 100 m²/g), Carbopack C (specific surface area 10 m²/g), Carboxen 1000 (specific surface area 1200 m²/g), or other equivalent adsorbents such as domestic GDX-502 (specific surface area 170 m²/g), GDX-201 (specific surface area 510 m²/g), GDX-101 (specific surface area 330 m²/g), etc. The particle size of commonly used adsorbents is generally 60 mesh ~ 80 mesh.
D.4 Instruments and equipment
D.4.1 Constant temperature test chamber: The temperature control accuracy is ±2 °C.
D.4.2 Gas chromatograph: It has capillary column split/splitless inlet, capable of electronic pressure control of carrier gas, with programmable temperature rise.
D.4.3 Mass spectrometer: Electron impact (EI) ionization source, which is capable of scanning from 35 amu to 270 amu, within 1 second. It has NIST mass spectrum library, manual/automatic tuning, data acquisition, quantitative analysis, spectral library search and other functions. D.4.4 Chromatographic column: 100% methyl polysiloxane capillary column (column-
1) or equivalent, which has an inner diameter of 0.18 mm, 0.25 mm, 0.32 mm, a film thickness of 1.0 µm, a length of 20 m ~ 60 m, can be selected according to needs.
D.4.5 Thermal desorption device: It can perform secondary thermal desorption on the adsorption sampling tube. Bring the carrier gas for desorption gas, into the gas chromatograph. The desorption temperature, desorption time, flow rate can be adjusted; the cold trap can realize quick temperature rise. Cold traps generally use semiconductor refrigeration. The part connected to the gas chromatograph of the thermal desorption device and the gas pipeline in the instrument shall use silanized stainless steel tubes, which can be heated uniformly, at least between 50 °C and 150 °C.
D.4.6 Adsorption tube aging device: The maximum temperature shall reach above 400 °C; the maximum carrier gas flow rate can reach at least 100 mL/min; the flow rate can be adjusted.
D.4.7 Oil-free sampling pump: The sampling flow rate shall be able to reach 20 mL/min ~ 500 mL/min. The sampling pump should adopt a sampling pump, which has a constant mass flow control; the flow accuracy shall not be lower than 2.5%.
D.4.8 Calibration of the flow meter: It can accurately measure the flow rate, within 5 mL/min ~ 500 mL/min; the flow rate accuracy shall not be lower than 2%; an electronic mass flow meter should be used.
D.4.9 Micro-syringes: 1.0 µL, 5.0 µL, 10.0 µL, 25.0 µL, 50.0 µL, 100 µL.
D.4.10 Vacuum pump: At least able to reach a negative pressure of 1.0 Pa x 105 Pa.
D.4.11 Automatic inflation device for sampling bags: The inflation flow rate is 0.1 L/min ~ 50 L/min; the accuracy shall not be lower than 2.5%.
D.5 Sample collection
D.5.1 Bag method - Absorption tube sampling
D5.1.1 Sampling bag preparation: Set the temperature of the constant temperature test chamber to 90 °C. Heat the empty chamber for 0.5 h ~ 1 h. Stretch the sampling bag.
Put it into the test chamber and heat it for more than 12 h. Test the background result of the sampling bag, before each use. When the blank value of the sampling bag is lower
D.6.2.2 Drawing of standard curve
Put the adsorption tubes of the standard curve series into the thermal desorption instrument. Perform analysis and determination, from low concentration to high concentration in sequence, according to the instrument reference conditions (D.6.1).
According to the mass ratio of target/internal standard and the characteristic mass ion peak area (or peak height) ratio of target/internal standard, use the least square method or the relative response factor, to draw the standard curve.
D.6.3 Sample analysis
Referring to the standard sample loading step, add 50 ng of internal standard substance to the adsorption tube of the collected sample. Perform TD-GCMS analysis on the sample, according to the instrument reference conditions (D.6.1).
D.6.3.1 Qualitative analysis
Qualitative by retention time and mass spectrum comparison.
D.6.3.2 Quantitative analysis
According to the external standard method, the internal standard curve method or the mean value of the average relative response factor of each point of the curve (the relative standard deviation of the relative response factor <= 30%, the relative response factor >= 0.010), calculate the content of the target component.
D.6.4 Blank test
Follow the same procedure as the sample analysis, to analyze the blank sample.
D.7 Calculation and presentation of results
D.7.1 Calculation of release amount
The release amount of benzene series in the performance film for automotive glass is calculated, according to formula (D.1):
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 38 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 191Graphical symbols marking for handling and storage of packages
- GB/T 1040.1-2018Plastics - Determination of tensile properties - Part 1: General principles
- GB/T 2680-2021Glass in building—Determination of light transmittance, solar direct transmittance, total solar energy transmittance, ultraviolet transmittance and related glazing factors
- GB/T 3979Methods for the measurement of object color
- GB/T 5137.1-2020Test methods of safety glazing materials used on road vehicles - Part 1: Mechanical properties tests
- GB/T 5137.2-2020Test methods of safety glazing materials used on road vehicles - Part 2: Optical properties tests
Similar standards
How to Download QC/T 1170-2022
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 11942-2022 — Test method of chroma for colour building materials
GB/T 191-2025 — Graphical symbols marking for handling and storage of packages
GB/T 2680-2021 — Glass in building—Determination of light transmittance, solar direct transmittance, total solar energy transmittance, ultraviolet transmittance and related glazing factors
Secure payment via Stripe
Payments accepted
QC/T 1170-2022
$480.00